Overload protection :
600V rms.
Continuity :
Built-in buzzer sounds when
measured resistance is less than 30
Ω
and
sounds off when measured resistance is
more than 150
Ω
,
between 30
Ω
to 150
Ω
the buzzer maybe sound or off
either.
Continuity Indicator :
2.7KHz Tone Buzzer.
DIODE
Test Current :
350
µ
A (Typical)
Open Circuit Voltage :
Approx. 1.8V
Input Protection :
600V rms.
Hz
Range
Resolution
Accuracy
±(
0.3%+ 5 D)
400.0Hz
0.1Hz
4.000KHz
0.001KHz
40.00KHz
0.01KH
The signal must have positive and negative
waveform of a cycle.
ACV Sensitivity :
> 10Vp-p (40KHz range)
> 1.5Vp-p (other range)
ACA Sensitivity :
> 15Ap-p (400.0Hz, 4KHz range)
This minimum sensitivity of current @ 40KHz
range is unspecified.
Max.Sensitivity :
600V rms & 400A rms
Overload protection :
600V rms.