CW-6S MICROCORE OWNER’S MANUAL
|
16
SLAVE CONTROLLERS
Multiple MagIQtouch Controllers can be
used to control individual zones. In such
installations there is always one “master
controller” located in a nominated “master
zone”. All other controllers become “slave
controllers”.
In such systems there are certain
principles that apply:
• If the master controller is set to OFF, no
other zone can be turned on.
• If the master controller is set to ON,
zones can be turned on and off from
the slave controllers.
• The primary operating mode (HEAT,
COOL and FAN ONLY) is dictated by
the master controller and cannot be
changed by a slave controller.
• The SETTINGS menu in a slave
controller will only display options
relevant for the applicable zone.
For Cooling mode:
• The Master Controller is the only active
controller.
• The set temperature or fan speed
can only be modified by the Master
Controller.
For Heating mode:
• The secondary operating mode
(MANUAL and PROGRAM) can be
selected for each zone from the master
and slave controllers.
• The set temperature is unique for each
zone and is set from the controller
located within the zone (either master
or slave).
• No fan speed limit control is available.
Fan speed is automatically controlled
by the heater to achieve the set
temperature.
Symptom
Cause
Action
The
MagIQtouch
Controller
has no
display.
The cable from
cooler may
not be fitted
correctly.
Refit cable.
Cable damaged
or broken.
Replace cable.
The
MagIQtouch
Controller
shows my
system is on,
but I can’t
hear the fan
working.
The set
temperature
has been
achieved and
the system is in
standby.
None required.
The Controller
is in
PROGRAM
mode and the
current time
period specifies
the cooler/
heater is “OFF”.
Review the
schedule
via the EDIT
button on the
PROGRAM
home screen.
POWER OUTAGES
Your MagIQtouch Controller may prompt
you to call a service agent to resolve a
service issue. If your controller has only
recently been installed, we recommend
you call your local Dealer for support first.
Otherwise, call the Service number on the
back of this manual.
After a power outage there will be a
prompt to adjust the time and date.
If AUTO RESTART option is ON in
general settings, the cooler or heater will
automatically restart in the last running
state before the outage.