background image

 |   

  

EA Evaporative Cooler

WALL CONTROL TYPES

WALL CONTROL FUNCTIONS

TWO SPEED WALL CONTROL

VARIABLE SPEED WALL CONTROL

ILL771-A

ILL2141A

USING YOUR AIR CONDITIONER

Evaporative air conditioners provide very 

effective cooling by drawing outside air through 

filter pads saturated with water. This water 

washes the air and cools it by the process of 

evaporation. There are a number of operating 

techniques and circumstances of which you 

should be aware to get the best performance 

from your evaporative air conditioner.

To provide effective cooling or ventilation, the 

air conditioner must be operated with sufficient 

openings to exhaust the air. For example: 

windows, doors or ducts. The location of the 

opening(s) will determine the pattern of cool air 

flow. The following are the minimum opening 

sizes required in square metres:

In light wind conditions more cooling can be 

obtained by opening additional windows and 

doors. In windy conditions close openings 

facing the wind.
Generally, openings opposite the supply vents 

are best. Some experimentation will soon 

show the arrangement most suited to your 

requirements. For a multiple outlet system, this 

is generally 1 (one) window opened 100 to 150 

mm per outlet.
For a short time, when operating with new 

filter pads, you may detect an odour like "wet 

timber”. This is the filter material becoming 

conditioned to use.
In many areas the water supply is quite hard. 

When this water is evaporated through the 

filter pads, the hardness is deposited as a 

scale on the pad. To reduce this scale build-

up and to retain efficient filter pads a small 

amount of water is bled from the system.
The continuous drain of small amounts of 

water ensures that fresh water is added to 

dilute any build-up of scale or salts. The bleed 

rate for your air conditioner will depend on 

local operating conditions and will be adjusted 

during installation.

Unit

Area (m2)

EA 90

0.4

EA 120, EAQ120

0.6

EA140

0.6

EA145

0.6

EA 150

0.8

ON

ON

OFF

OFF

COOL

SPEED

INTERNATIONAL

AIR

TWO SPEED AND VARIABLE SPEED AIR 

CONDITIONERS.

Your evaporative air conditioner has control 

switches to provide for the benefits of fresh 

air ventilation and cooling at high and low air 

flows. There are two types of control switches 

available: Two Speed and Variable Speed.

Your control panel offers independent control 

for the fan and cooling functions.

TO START THE AIR CONDITIONER

1. Switch the COOL control on.

2. Turn on the AIR (fan) control and using 

The SPEED switch (HI/LO switch or Variable 

knob), select the fan speed you require.

When ventilation only is required (air flow with 

no cooling) turn the COOL switch off, and 

select the fan speed to provide the air flow you 

require.

TO STOP THE AIR CONDITIONER

Switch the COOL control off, then switch the 

AIR control off.

Summary of Contents for Braemar EA 120

Page 1: ...OWNER S MANUAL EA Evaporative Coolers English Original English Instructions ...

Page 2: ......

Page 3: ...sed WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecti...

Page 4: ... rooms provide an exhaust opening about 2 times the vent size of the room Where the design of the building prevents adequate exhaust consideration should be given to the provision of mechanical extractions such as an exhaust fan Details on how to register your product warranty can be found near the end of this Owner s Manual As with any product that has moving parts or is subject to wear and tear ...

Page 5: ...Air Conditioner 2 To Stop the Air Conditioner 2 Using Your Air Conditioner 2 MAINTENANCE Access for Servicing and Maintenance 3 SEASONAL MAINTENANCE Pre season Maintenance 3 Post season Maintenance 4 Routine Preventative Maintenance 4 Check your Local Regulations 4 ROUTINE SERVICE CHECKLIST 5 TROUBLE SHOOTING 6 HOW TO REGISTER YOUR PRODUCT WARRANTY AUSTRALIA ONLY 7 WARRANTY TERMS AND INFORMATION A...

Page 6: ...n odour like wet timber This is the filter material becoming conditioned to use In many areas the water supply is quite hard When this water is evaporated through the filter pads the hardness is deposited as a scale on the pad To reduce this scale build up and to retain efficient filter pads a small amount of water is bled from the system The continuous drain of small amounts of water ensures that...

Page 7: ...om the unit by removing the overflow or overflow bleed funnel Check pulleys for wear and correct alignment Check V belt for wear Thoroughly clean and dry the bottom of the water tank Replace filter pad frames Ensure they are the correct way up If water flow appears low there may be a problem with foreign material clogging the pump or pump strainer To correct remove pump dismantle base clean and re...

Page 8: ...OUTINE PREVENTATIVE MAINTENANCE All units can benefit from routine preventative maintenance This may be required more frequently if you are operating under harsh conditions in adverse environmental situations in very dusty areas or running for long hours We require that the following components and the operation thereof be checked after the first year then every 2 years as routine maintenance 1 Be...

Page 9: ...n no flow restrictions Bleed rate set COMPONENT FUNCTION Pump operation Bleed Overflow operation Motor operation set motor amps where required Wall control operation GENERAL OPERATION Water level set point Water distribution across pads no dry spots Airflow through system outlets General product condition Note Includes correct refitting of all components and items and any required replacements Ser...

Page 10: ...ll Service see Rear cover Air flow but not cool Insufficient water reaching filter pads Ensure water supply to unit is turned on Clean pump filter Pump failure Call Service to repair Fan stops and then restarts Motor overload The fan motor is fitted with an automatic thermal overload protector which will be reset when the motor cools down If the motor stops and starts continuously it should be inv...

Page 11: ...e Important Note You need to have the following information to complete your registration your unit model and size serial number date your system was installed name of the dealer you purchased it from Please complete this section You will also need to retain your purchase receipt and proof of any warranty period extension Brand _________________________________________________________ Model ______...

Page 12: ...used for a commercial purpose Braemar EA Plug Connect the warranty period shall be two 2 years regardless of whether the Goods are used for personal residential household purposes or any other purpose however the warranty shall only cover the cost of parts not labour or any other charge 2 The warranty granted under clause 1 applies to all components which form part of the original evaporative air ...

Page 13: ... address below within the Relevant Warranty Period i the legible and unmodified original proof of purchase which clearly indicates the name and address of the original retailer the date and place of purchase the product name or other product serial number ii all of your records of all service and maintenance carried out to the Goods plus the Maintenance Schedule in the Owner s Manual if it was pub...

Page 14: ...ided Step 5 Select BOOK A SERVICE or Phone 1300 650 644 to be directed to your closest authorised Service Agent PRIVACY NOTICE Seeley International Pty Ltd ABN 23 054 687 035 will use the personal information you provide us with to provide warranty support for the product you have purchased and to inform you about other products and services If you choose not to supply us with the information requ...

Page 15: ......

Page 16: ...cy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected MANUFACTURED BY SEELEY INTERNATIONAL PTY LTD 112 O SULLIVAN BEACH RD LONSDALE SA 5160 AUSTRALIA IMPORTED BY SEELEY INTERNATIONAL EUROPE LTD UNIT 11 BYRON BUSINESS CENTRE DUKE STREET ...

Reviews: