2. Electrical characteristics and parameters
2.1 Detection angle and distance
Content
Minimum Typical Maximum Units
MR60FDA1
Radius of movement of people detection [1]
-
6
metre
Fall monitoring radius [2]
-
2.5
metre
Radar detection angle (horizontal)
-
100
-
degree
Radar detection angle (pitch)
-
100
-
degree
Note: [1][2] Radar hang height 2.8 m, radius of radar projection.
2.2. Electrical characteristics
2.
3. RF performance
Parameters
Operating frequency (fTX)
58
-
63.5
GHz
Transmitted power (Pout)
-
-
6
dBm
Content
Minimum
Typical
Maximum
Units
Operating voltage (VCC)
4.5
5.0
6
V
Operating current (ICC)
90
93
100
mA
Operating temperature (TOP)
-20
-
+60
°C
Storage temperature (TST)
-40
-
+80
°C