5
Notice: Only central role is used. If remote device has already connected to other device or shut down,
“OK+CONNF” will received after about 10 Seconds.
4
)
Clear Last Connected device address
Send
:
AT+CLEAR
Receive
:
OK+CLEAR
5
)
Query Module Work Mode
Send
:
AT+MODE?
Receive
:
OK+Get:[para]
Range
:
0~2. 0: Transmission Mode; 1: PIO collection Mode + Mode 0 ; 2: Remote Control Mode + Mode 0 .
Default 0.
Set Module Work Mode
Send
:
AT+MODE[]
Receive
:
OK+Set:[para]
6
)
Query Module name
Send
:
AT+NAME?
Receive
:
OK+NAME[para1]
Set Module name
Send
:
AT+NAME[para1]
Receive
:
OK+Set:[para1]
e.g.
:
Send: AT+NAMESeeed
,
Receive : OK+Set:Seeed
Notice: Name would change after next power on.
7
)
Query Pin Code
Send
:
AT+PASS?
Receive
:
OK+PASS:[para1]
Range : 000000~999999. Default: 000000.
Set Pin Code
Send: AT+PASS[para1]
Receive
:
OK+Set:[para1]
8
)
Restore all setup value to factory setup
Send
:
AT+RENEW