Cleaning the Needles 
 

If a seed, soil, or other debris should collect in the needle and block it, this 
machine is equipped with a needle cleaner. 
 
Remove the blocked needle turning counterclockwise.  Place needle onto needle 
cleaner located at the base of the operator control panel in the lower right corner.  
Hold needle into place but DO NOT PUT FINGERS OR HANDS ON TOP OF 
THE NEEDLE as it is positive air and can cause injury.  Slightly turn the needle 
cleaning knob counterclockwise until debris clears from the needle.  You should 
not require more than one half turn to clear debris from the needle. 
 
 

 

© Seederman Seeders 2003 

- 11 -

 
 
If the needle fails to clear on the needle cleaner, it may be 
necessary to soak the needle in warm water for about one hour, 
then try cleaning it on the needle cleaner again. 
 
The needle cleaner is located at the back and to the right of the 
machine to prevent any blowing debris from blowing into 

operators eyes.  For this reason, operator should not move from his normal 
operating position when cleaning needles. 

Figure 14.  Needle cleaner knob.

 
 

Summary of Contents for GS1

Page 1: ...GS1 Semi Automatic Needle Seeder Owners Manual and Operating Guide Seederman Seeders 2003 ...

Page 2: ...ntents Introduction 2 Space environment and air requirements 3 Connecting machine to air source 4 Inserting needles 5 Attaching sowing kit 6 Leveling the machine 7 Checking the index length 8 Operation 9 Cleaning the needles 11 Maintenance 12 Safety precautions 14 Contacts 15 ...

Page 3: ... sow varies greatly upon several factors including size of tray seed type and operator You should expect to sow UP TO 120 size 288 trays or 80 size 512 trays per hour This machine will accommodate plug trays from 50 to 512 cells The operator can change the sowing kit from one plug tray to another in less than 5 minutes Seederman offers a 14 day return policy and a 1 year warranty on all parts exce...

Page 4: ...pport this machine The table should be able to withstand the weight of the machine and 3 filled trays at a minimum As this machine is manufactured using high grade aluminum it is perfectly capable of withstanding the hot and humid conditions of most greenhouses however you should avoid running this machine in or under a water source The GS1 Semi Automatic Needle Seeder was engineered to operate us...

Page 5: ...rrect to your air source you can purchase a inch npt fitting at most supply stores The regulator is located at the top of the mast head on the left side as the operator is facing the machine At the base of the regulator is an orange button By pressing this button you can release any trapped water in the regulator Figure 1 Regulator showing air line properly connected to valve Seederman Seeders 200...

Page 6: ...dth if necessary To adjust the slide rails unlock the left and right handles slide the rail to the desired width then relock the handles Insert the tray into the machine far enough so that the tray slides under the drop tube bar If necessary replace the drop tube bar to match the tray you are using see next chapter for instructions to replace drop tube bar Having the tray in place will aid you in ...

Page 7: ... REMOVE THE TUBES FROM THE BOTTOM BAR Insert a new drop tube bar onto the threaded rod place the washers over the rod and screw the handles into position tightening them Lastly insert the tubes into the top bar Make sure to fit the tube to the uppermost position inside the tube bar to insure there are no gaps where seed can collect You may need to twist the tubes SLIGHTLY to insert them Depending ...

Page 8: ...tly dance over the surface of the pan without undue bouncing A properly leveled machine will distribute the seed forward of the pan near the needles and evenly from front to back with the majority of the seed centrally located If the seed falls too far to the back of the machine raise the rear leveling pads If the seed falls too far forward of the machine raise the front leveling pads If the seed ...

Page 9: ...ne should be pre marked on the indexing bar with the placement for the size trays you are using If the bar is off the mark or if you are using a different size tray you can adjust the indexing by using the silver and black thumbscrews on the adjustment rod To shorten the index move the silver thumbscrew inward toward the drop tube bar then tighten the black thumbscrew To lengthen the index move th...

Page 10: ...nd offer it so that the indexing arm is in the second cell row Turn the handle upwards and to the right to index the cell once until the first cell is directly under the drop tube bar Figure 10 Vibrator swi ch and adjustment knob t Figure 9 Operato s handle showing direction of movement r Turn the vibrator switch to the on position and adjust if necessary Turn the vacuum switch to the left until t...

Page 11: ...res so little strength Repeat sowing until the full tray is sowed After you have finished sowing all your trays you can use the seed collector to neatly and completely collect any remaining seed left in the pan Figure 13 Seed collector and swi ch t The seed collector is located on the operators panel at the left hand side Turn the vibrator pan on as it is easier to collect the seed while vibrating...

Page 12: ...ly turn the needle cleaning knob counterclockwise until debris clears from the needle You should not require more than one half turn to clear debris from the needle Seederman Seeders 2003 11 If the needle fails to clear on the needle cleaner it may be necessary to soak the needle in warm water for about one hour then try cleaning it on the needle cleaner again The needle cleaner is located at the ...

Page 13: ... operators have found that a small amount of residue from seed even pelletized actually assists the seed dropping through the tube even faster so you may want to try the tubes first Check bolts and handles to insure they are secure Prior to each use Connect air and check vibrator vacuum pressure eject pressure and seed cleaner pressure to insure that all air hoses gauges and regulator are working ...

Page 14: ...ntally spilled into pan it may be necessary to clean with a small amount of mild detergent dip a rag into solution then clean pan then rinse pan with clean water Always make sure pan is dry before use Please do not feel it necessary to repair your machine yourself if something should break Please call us and most of the time we can talk you through a minor problem or repair over the telephone If t...

Page 15: ...achine Needles should be kept in a safe place away from children There are pinch points on this machine Caution should be exercised to avoid placing hands or other body parts on or near the indexing arm see figure 2 or the indexing cylinder see figure Also keep fingers and clothing out of the way when adjusting the side guide rails see figure 3 to avoid pinching when moving these into position Use...

Page 16: ...istance or have any questions about your Seederman Seeder please contact us Write us Seederman Seeders PO Box 93 Braceville IL 60407 E mail us Graham seederman com Susan seederman com Telephone us 815 237 0423 Fax us please telephone before faxing 815 237 0423 ...

Reviews: