 A2 dp 

5 Operation 

 

 

 

 

 

 

 

 

 

 

 

5

 

 Operation 

5.1

 

Starting up 

When the system is switched on, it retains the settings from the previous usage. This also applies 

to the Bank selection. The system is then in the Status Mode. If the red Mute LED is lit as a result 

of  the  previous  setting,  no  signal  will  be  passed.  Pressing  the  Set  button  once  will  un-mute  the 

system. The Mute LED will go off, and signal will be passed. 

5.2

 

Selecting a bank 

 

The  loudspeaker  presets  are  stored  in  the  DSP  controller  in  up  to  3 

banks. To change banks, press and hold the Mode button  whilst the 

loudspeaker is switched on. 

1.  Press and hold the Mode button. 

2.  Connect the power cable (PowerCon blue). 

3.  Corresponding LEDs blink to indicate the chosen bank. 

4.  Release the Mode button. 

When  the  power  cable  is  connected,  the  level  and/or  preset  LED 

lamps  blink  to indicate  which  bank  is  selected.  The  level  LED  blinks 

to  indicate  the  first  bank,  the  preset  LED  for  the  second.  The  third 

bank is indicated by both LEDs blinking. 

If  only  one  bank  is  programmed,  there  is  no  possibility  to switch  the 

bank. 

Bank 1 

– 

Default Settings

 

Bank 2 

Bank 3 

Flat 

HP 

Low-Boost 

Switchable Soft Mode 

Summary of Contents for 00230/III/dp

Page 1: ...User Manual A2 dp Version 3 2 18 05 2020 ...

Page 2: ...nectors 7 4 3 Controls 8 4 4 Status indication 8 5 Operation 9 5 1 Starting up 9 5 2 Selecting a bank 9 5 3 Setting level 10 5 4 Recalling presets 11 5 4 1 Preset Bank 1 Default Settings 11 5 5 Reprogramming of dp speakers with preset audio files 12 5 6 Locking the buttons 12 6 Technical specifications 13 7 Declaration of conformity 14 ...

Page 3: ...imize disruptive noise The default state of the integrated DSP controller is the standard configuration as described in this manual Custom presets can be installed by the user but must be programmed with the LPI Loud speaker Programming Interface by the manufacturer The preset file is a custom audio file which is simply played into the audio input of the controller In this manner individual config...

Page 4: ... power connected This can damage or destroy magnetic storage devices The PowerCon loop through connector is under power when the device is in operation Observe all relevant safety regulations at all times General safety precautions The installation and de rigging of this equipment should only be car ried out by appropriately qualified and experienced personnel and according to all relevant safety ...

Page 5: ...void operating in envi ronments below 5 C or above 40 C Be aware of the possibility of condensation forming inside the housing due to rapid changes in temperature Allow the loudspeaker to adjust to ambient temperature before operation Leave the device switched on if operating in unfa vorable conditions To prevent overheating do not operate the loudspeaker in the direct vicinity of strong heat sour...

Page 6: ...A2 dp 4 Connectors Indicators 6 4 Connectors Indicators 4 1 Connection panel PowerCon grey 3 XLR connectors 1 PowerCon blue 2 ...

Page 7: ...er approximately 3 seconds Avoid repeatedly switching the system on and off particu larly when it is operating PowerCon grey 3 110 230 VAC loop through connector This connector is to be used when multiple active loud speakers are to be provided with power from one source Please observe carefully the maximum power capacity of the power source The nominal power consumption of the A2 dp under full po...

Page 8: ...ion Mute LED Lights red when the system is muted press the Set button in Status Mode or in technically critical conditions Limit LED Lights yellow when the limiter is limiting one or more amplifier chan nels Signal LED Lights green when a signal of more than 20 dBu is present The LED still lights up when the system is muted Power LED Lights when the system is powered up ...

Page 9: ...e DSP controller in up to 3 banks To change banks press and hold the Mode button whilst the loudspeaker is switched on 1 Press and hold the Mode button 2 Connect the power cable PowerCon blue 3 Corresponding LEDs blink to indicate the chosen bank 4 Release the Mode button When the power cable is connected the level and or preset LED lamps blink to indicate which bank is selected The level LED blin...

Page 10: ...values between 6 dB and 12 dB are available with 0 dB being the standard setting The setting is made using the Set button The green LED above on the left indicates that you are in Level Mode whereby the four vertically arranged LEDs now lighting up green indicate the respectively set value If two adjacent LEDs light up the intermediate value of the printed levels is set Level setting options 6 dB ...

Page 11: ... Bank 1 Default Settings This bank contains the recommended settings for A2 dp systems fitted with the DPLM DSP control ler Flat Preset for single application without any additional subwoofer HP Flat preset with a higher cut off frequency for the high pass filter for combination with a subwoofer The higher cut off frequency allows a higher maximum sound pressure level to be achieved Low Boost Base...

Page 12: ...ollows 1 Use a mini jack XLR stereo cable to connect the headphone output to the XLR input of the self powered box Use only one of the XLR connectors 2 Mute the box by pressing the Set button in Status Mode The Mute LED lights up The DSP controller can only receive data in the muted state 3 Make sure your computer s volume is set to 100 4 Load the wav file received from SEEBURG acoustic line into ...

Page 13: ...requency excursion minimum 95 Hz X Overpoint acoustical depends on preset Coverage horizontal vertical 90 x 60 rotatable Max Splay Angle Connectors Neutrik XLR in out Neutrik PowerCon in out Handles 1 x Rigging flying points 4 x M10 35 mm pole mount Weight 10 5 kg Size height x width x depth 51 0 x 21 0 x 21 0 cm Order No 00230 III dp The technical data sheet and further information about possible...

Page 14: ...996 classes E1 to E4 DIN EN 55103 2 1996 classes E1 to E4 Declared by Winfried Seeburg SEEBURG acoustic line GmbH Place and date Senden 01 01 2018 Legally binding sign ____________________________________________ The attachments constitute part of this declaration This declaration certifies conformity with the listed guidelines but does not guarantee any product characteristics The safety precauti...

Page 15: ...ic line Produkte sind nur für den gewerblichen Einsatz bestimmt All specifications are current at the time of publishing but are subject to change SEEBURG acoustic line Produktions und Vertriebs GmbH Auweg 32 D 089250 Senden Freudenegg Fon 49 0 7307 97 00 0 Fax 49 0 7307 97 00 29 www seeburg net info seeburg net ...

Reviews: