background image

SEE WATER, INC.

Three Phase Duplex Control Panel 

Installation and Operation manual

             WD3P-4-302X

Notes:

Troubleshooting:

Caution: Before checking electrical connections within the control or          
attempting to replace any components, turn off all branch circuits supplying 
power to the main control panel.

Alarm Circuit:

• 

To test the alarm light and buzzer, press the test button on the front 
panel. If either the light or buzzer do not indicate, replace the light 
bulb or buzzer with the same type.

Control Board and Fuse:

• 

If the power on light is not illuminating on the front panel, check the 
voltage at TS1-1 and TS1-2 with a voltage meter. The voltage should 
read 120VAC. If voltage is present, check the fuse in the fuse box. If 
the fuse is blown, replace fuse with same type. The dry contacts are 
rated for 0-60 VAC or VDC, 1 amp max.

Floats:

• 

The control board has individual float status indicators that will            
illuminate when the floats are in the closed position. Check floats for 
entanglement, full range of motion. Replace damaged floats.

Warranty:

See Water, Inc. warrants that products of its manufacture are 
free from defects in material and workmanship for a period of 5 
years from the date of purchase. This date shall be determined 
by the date on the invoice and the serial number on the product.  

Replacement of the product is at the discretion of See Water, 
Inc. This warranty is valid when the product is installed in 
compliance with the manufacturer’s installation instructions. 
The manufacturer’s obligation under this warranty shall be 
limited to the repair or replacement of any parts found by 
the manufacturer to be defective, provided that the product 
is returned to See Water, Inc.’s factory, postage prepaid with 
proof of original purchase included. 
 
The manufacturer of this warranty shall not be liable under this 
warranty if the product has not been properly installed; any 
alterations/additions/changes to the product will result in a void 
warranty. Failure to properly install and test this product can 
result in personal injury or equipment malfunction.  

See Water, Inc. shall not be liable for any loss, damage or 
expenses from installation or use of its products.

www.seewaterinc.com 

951.487.8073 • 888.733.9283 • [email protected] 

22220 Opportunity Way, Suite 101 •  Riverside,  CA 92518

 

Page 3-3

IM 751 REV. 01/20

Reviews: