U S E R M A N U A L · H Y D R O N i R E D +
U S I N G M O D E
T R O U B L E S H O O T I N G
Problem
Cause
Solution
No water out
The battery is exhausted
Charge the battery
Water supply cut off
Check supply
Dirty in the filter
Clean the filter
Water pressure is too low
Raise the pressure
No water
Some conductor activates the
faucet
Removes the conductor, press
the button of the control box
Low flow of water
Water supply is turned down
Adjust water supply
The filter is too dirty
Clean the filter
Water pressure is too low
Raise the pressure
Excessive water flow
Water pressure is too high
Adjust pressure
Short cycles of battery
Incorrect batteries
Change to 4 AA Alkaline batte-
ries
The indicator light in the sen-
sor is not turning on
The light is broken
Change the light or circuit
board
The circuit board is wet or signal
line is wet
Dry out
The battery is exhausted
Change the battery
Poor connection of battery
Change the battery connection
Before use
During use
After use
NOTE:
When your hand enters the inductive field the water flows. Remove your hand from the field to stop the water. It will stop automatically
after flushing 30 seconds continuously. Remove your hand from the inductive field for 3 seconds, then enter the field to flush again.