Security Tronix ST-PTZMINI-540W Installation Manual Download Page 3

v2.0  3/21/11 

 

INSTALLATION AND OPERATION 

  

 

 

 

 

CAUTION: To reduce the risk of electrical shock do not remove the cover or back of this 

unit. No user serviceable parts are inside. 

 

CAUTION: To prevent electric shocks and risk of fire hazards, do not use other than 

specified power source. 

 
 

1.  UNPACKING and HANDLING 

 

Each unit is shipped assembled and factory tested. 
 
Ensure that all accessories are removed from the container before discarding packing material 
 

2.  MECHANICAL INSPECTION 
 

Inspect the front and rear of the equipment for shipping damage. Make sure the equipment is 
clean,  and  no  connectors  are  broken,  damaged,  or  loose.    If  equipment  appears  to  be 
damaged or defective please contact your distributor or SecurityTronix at 1-610-429-1511 for 
assistance. 

 

3.   SPECIAL ATTENTION 
 

a.  The  installer  must  comply  with  electrical  safety  standards.  There  must  be  sufficient 

space  between  the  camera’s  power  supply  and  video  line  and  any  high  voltage 
equipment and/or cables. 

b.  To  help  ensure  the  camera’s  life  and  proper  operation  do  not  point  the  camera 

towards the sun or strong light. 

c.  Do not install the camera in an environment where the temperature is above 122

°

 F.  

d.  Do not install the camera near a magnetic field or a high-power motor. 
e.  Do not mount the camera near a radiator or heater. 
f.  Only use a dry cloth to clean the camera. If there is dirt that is difficult to remove wipe 

gently with a mild detergent. Never use strong or abrasive detergents. 

g.  A minimum 12VDC 1.2A power supply must be used.  AC power cannot be applied. 

Using an AC or other incorrect power supply will damage the camera. 

h.  Only qualified installers are allowed to install, test and disassemble the camera. 
i.  The camera is a low voltage product. If installed outdoors proper safety and lightening 

grounding are required. 

 

 

 

 

 

This symbol is intended to alert the user to the presence of important operating and 
maintenance (servicing) instructions. 

This symbol is intended to alert the user to the presence of uninsulated “dangerous 
voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a 
risk of electrical shock.  

Summary of Contents for ST-PTZMINI-540W

Page 1: ...v2 0 3 21 11 1 INSTALLATION MANUAL ST PTZMINI 540W Medium Speed Intelligent Dome PTZ Color Camera ...

Page 2: ...AWB BLC and AES The ST PTZMINI 540W uses the PELCO D protocol SPECIFICATIONS ST PTZMINI 540W Specifications Typical 1 Image Sensor 1 3 SONY Super HAD CCD with DSP 2 Resolution 540TVL Color 600TVL B W 3 Lens Auto Iris 5mm 15mm 3X optical zoom w auto focus 4 Illumination 0 01 Lux 5 Video Output 1 0 0 2VP P 75Ω compound video signal 6 Signal to Noise Ratio 50dB 7 Manual Speed Horizontal 0 5 50 s Vert...

Page 3: ...cables b To help ensure the camera s life and proper operation do not point the camera towards the sun or strong light c Do not install the camera in an environment where the temperature is above 122 F d Do not install the camera near a magnetic field or a high power motor e Do not mount the camera near a radiator or heater f Only use a dry cloth to clean the camera If there is dirt that is diffic...

Page 4: ... the required surveillance area and environment 5 FUNCTIONS and OPERATION Configuring the ST PTZMINI 540W The ST PTZMINI 540W s control board has an 10 DIP switch used to set a number of parameters including address communications protocols and control protocols Any command used should conform to the target camera and that camera s response should occur only when it has been addressed Of the 10 DI...

Page 5: ...1 1 1 0 0 0 0 47 1 1 1 1 0 1 0 0 16 0 0 0 0 1 0 0 0 48 0 0 0 0 1 1 0 0 17 1 0 0 0 1 0 0 0 49 1 0 0 0 1 1 0 0 18 0 1 0 0 1 0 0 0 50 0 1 0 0 1 1 0 0 19 1 1 0 0 1 0 0 0 51 1 1 0 0 1 1 0 0 20 0 0 1 0 1 0 0 0 52 0 0 1 0 1 1 0 0 21 1 0 1 0 1 0 0 0 53 1 0 1 0 1 1 0 0 22 0 1 1 0 1 0 0 0 54 0 1 1 0 1 1 0 0 23 1 1 1 0 1 0 0 0 55 1 1 1 0 1 1 0 0 24 0 0 0 1 1 0 0 0 56 0 0 0 1 1 1 0 0 25 1 0 0 1 1 0 0 0 57 1 0...

Page 6: ...transferring preset positions is done through the PTZ Controller The ST PTZMINI 540W supports 128 preset positions Set Preset Positions The ST PTZMINI 540W supports up to 128 preset positions Setting the preset positions using a PTZ Controller is done as follows by way of example Move the joystick so the camera is on the location or image for the first preset point Push Preset button on the PTZ Co...

Page 7: ...tivate Tour Route 101 6 TROUBLESHOOTING a No picture after applying power i check all plugs and cables are securely connected to the proper connectors ii ensure your power supply is providing the correct voltage and current b The picture has ripples i check to see if the power supply is experiencing AC ripple if so a filter may be required ii determine if the monitor is faulty iii determine if oth...

Page 8: ... Bit 5 Bit 3 is 0 without exception Bit 4 is auto scanning control points 1 0 ON OFF Bit 2 Iris Smaller 1 valid Bit 1 Iris Larger 1 valid Bit 0 Focus Nearer 1 valid Command Code 2 Bit 7 Focus Farther 1 valid Bit 6 Bit 5 for zoom control Bit 6 far away from the object 1 valid Bit 5 near the object 1 valid Bit 4 Bit 3 Bit 2 Bit 1 separately control the movement down up left right 1 valid Bit 0 is 0 ...

Page 9: ...e 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Synchronized Byte Address Code 00H 09H 00H Auxiliary Switch Confirmation Code Turn Off the Command of Auxiliary Switches Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Synchronized Byte Address Code 00H 0BH 00H Auxiliary Switch Confirmation Code Auxiliary Switch Range is 01 08 ...

Reviews: