background image

ST-POE24M

 Hardware Installation Manual 

- 11 -

through  a  console  cable,  you  can  configure  and  monitor  the  switch  of 

ST

-POE24M 

by running  a terminal emulation software, such as super Windows terminal. The cable 
is  provided  according  to  the  host.  The  communication  parameters  of  the  terminal 
serial port can be set to a rate of 9600bps, eight data bits, one stop bit, no sum check 
bit and traffic control. 

The RJ45 connector of the console port is shown in the following figure. The RJ45 plug 
corresponds to the RJ45 socket, whose pins can be aligned from left to right with the 
value from 1 to 8. 

Figure 3-3    RJ-45 connector of the console port 

Figure 3-4 Connecting the console port of 

ST-POE24M

 and computer 

Table 3-1   Definition of the pins of the UTP port 

No. 

Name 

Symbol 

Remarks 

Carrier Detecting 

CD 

No connect 

Data receiving 

RXD 

Input 

Data-line device ready 

DSR 

No connect 

Summary of Contents for ST-POE24M

Page 1: ...ST POE24M INSTALLATION MANUAL www securitytronix com www nacebrands com ...

Page 2: ...8 2 4 Installation Tools and Device 8 Chapter 3 Installing the ST POE24M Switch 9 3 1 Installation Flow of ST POE24M 9 3 2 Installing the Chassis of the Switch 9 3 2 1 Installing the Machine Box on the Desk 10 3 2 2 Installing the Chassis on the Cabinet 10 3 3 Connecting the Port 10 3 3 1 Connecting the Console Port 10 3 3 2 Connecting Fast Ethernet Interface 12 3 3 3 Connecting the 1000M Ethernet...

Page 3: ...cators Each fast Ethernet port has the POE function Each port can provide the outside up to 30W power consumption and the total power consumption reaches 400W 1000M optical electrical port Electrical port 10 100 1000M auto adaptation MDI MDIX auto identification of cable UTP RJ45 port and the LINK ACT indicators SFP port having LINK ACT indicators Console port An RJ45 port with a rate of 9600 bps ...

Page 4: ...cal signals 8 LINK ACT Normal mode of the indicator indicating the LINK ACT state of each port POE mode of the indicator indicating the POE power supply state of each port Normal mode If the indicator is always on the link on the port is normal If the indicator flickers the data is received or transmitted through the port POE mode If the indicator is always on the port is powered through the POE m...

Page 5: ...EE 802 1q tagged VLAN IEEE 802 3x Flow control IEEE 802 3ad Link aggregation IEEE 802 3af standard Network management standard RFC 1157 SNMP v1 v2 RFC 1213 MIB II RFC 1757 RMON 1 2 3 9 Memory EPROM 512k Bytes Flash Memory 8M Bytes SDRAM 64Mbytes Standard configuration 24 10 100Base TX ports One Console port Four fixed 1000M optical electrical Ethernet ports Specifications 442 50 315 00 44mm Workin...

Page 6: ...ST POE24M Hardware Installation Manual 4 1 3 ROHS Description ...

Page 7: ...h the power socket 2 When the lifetime of our products ends handle them according to national laws and regulations or send these products to our company for collective processing 3 Caution It is not recommended to connect the POE ports of two POE devices directly 2 2 Safety Advice 2 2 1 Safety Principles Keep dustless and clean during and after the installation Place the switch in a safe location ...

Page 8: ...d the power socket Only professionals are allowed to operate and maintain the device Read the installation guide carefully before the system is powered on Note Check potential dangers such as the humidity ungrounded extension power cords and frayed power lines Turn off the switch and remove the power line before installing or uninstalling the chassis or working beside the power Do not work alone i...

Page 9: ...easures assist you to design the proper environment for the switch Make sure that the workshop is well ventilated the heat of electrical devices is well discharged and sufficient air circulation is provided for device cooling Avoid damage to devices by following electrostatic discharge prevention procedures Put the chassis in a place where cool air can blow off the heat inside the chassis Make sur...

Page 10: ...vention measures for a building Caution If the power supply system does not have good grounding or the input power disturbs too much and excessive pulses exist the error code rate of communication devices could increase and potentially cause hardware failure 2 4 Installation Tools and Device The tools and devices to install the ST POE24M switch are not provided by the ST POE24M switch You yourself...

Page 11: ...3 1 Installation Flow of ST POE24M 3 2 Installing the Chassis of the Switch The chassis of the switch can be installed on the desk or can be fixed to other cabinets Your network installation requirements can be met if you conduct the operations according to the following procedure Installing the switch on a desk Installing the Chassis in an equipment cabinet ...

Page 12: ...u fix the brackets the front template of the switch faces forward The detailed operations are shown in Figure 3 1 Figure 3 1 Fixing the machine box of the switch After the brackets are installed install the switch on the cabinet See Figure 3 2 Figure 3 2 Installing the switch on the cabinet 3 3 Connecting the Port 3 3 1 Connecting the Console Port The switch of ST POE24M has a Console port The rat...

Page 13: ...data bits one stop bit no sum check bit and traffic control The RJ45 connector of the console port is shown in the following figure The RJ45 plug corresponds to the RJ45 socket whose pins can be aligned from left to right with the value from 1 to 8 Figure 3 3 RJ 45 connector of the console port Figure 3 4 Connecting the console port of ST POE24M and computer Table 3 1 Definition of the pins of the...

Page 14: ...witch and the outside console terminal device One end of the cable is a 8 pin RJ45 plug and the other end is a 9 hole plug DB9 The RJ45 plug is put into the socket of the console port on the ST POE24M switch The inner line connection in the cable is shown in figure 3 1 The console cable is numbered as RLC0301 Figure 3 5 Cable connection at the console port 3 3 2 Connecting Fast Ethernet Interface ...

Page 15: ...irect through cross network cables when it connects other Ethernet terminals Figure 3 7 Connecting the 10 100Base TX port and other Ethernet terminals Table 3 2 Definition of the pins of the UTP port No Name Symbol Remarks 1 Sending the normal phase of the data TPTXD Output 2 Sending the paraphase of the data TPTXD Output 3 Receiving the normal phase of the data TPRXD Input 6 Receiving the parapha...

Page 16: ...s with EIA TIA 568A 3 3 3 Connecting the 1000M Ethernet Port IP POE24M provides four fixed 1000M optical electrical Ethernet port The indicators on the right side are LINK ACT lights To use the optical port you need insert the SFP module to the port and then connect other Ethernet devices through the optical fiber cable If the port is inserted with the SFP module the corresponding electrical port ...

Page 17: ...T POE24M support the MDI MDIX auto identification of the cable ST POE24M can adopt five classes of direct through cross network cables when it connects other Ethernet terminals Figure 3 12 Connecting the 1000Base TX port and other Ethernet terminals Table 3 3 Definition of the pins of the 1000M RJ45 port No Pin Name Symbol Remarks 1 Sending the normal phase of the data TXD1 Output 2 Sending the pa...

Page 18: ...allation Before starting up the switch perform the following checks after the switch is installed If the switch is installed on a cabinet check whether the installation point between the cabinet and the switch is strong If the switch is installed on a desk check whether there is enough space for the switch to discharge its heat and whether the desk is stable Check whether the connected power meets...

Page 19: ...switch required tools and operation methods Caution When the power cable is still connected to a power source do not touch it When you open the cover of the switch you may use the following tools Screwdriver Static armguard Perform the following steps to open the cover of the switch Turn off the power to the switch Remove all cables connected the back of the switch Take out the bolt from the chass...

Page 20: ...ribes how to put the cover and close the chassis Do as follows Assemble them according to their locations and joint them together along their sides See the following figure When the cover and the bottom are closed let the cover slide the slot of the front template at the bottom Nail the bolt and screw it tightly with the screwdriver Reinstall the switch on the cabinet or the desk Reconnect all cab...

Page 21: ...switch is too hot check whether the air outlet and air inlet are clean and then do relative operations in section 2 3 Requirements for Common Locations The working temperature of the switch is from 0 to 40 Celsius degrees If the switch cannot be started and the PWR indicator is off check the power 5 1 2 Faults Relative with Port Cable and Connection Do the following checkups to help remove the fau...

Page 22: ... indicator is on 2 SYS System indicator If the indicator is always on the system is being started If the indicator flickers the system works normally 3 LINK ACT Indicator of each port If the indicator is always on the link on the port is normal If the indicator flickers the data is received or transmitted through the port ...

Page 23: ...rdware riot war invasion act of foreign enemies hostilities regardless of whether war is declared civil war rebellion revolution insurrection military or usurped power or confiscation terrorist activities nationalization government sanction blockage embargo labor dispute strike lockout or interruption or failure of electricity air conditioning or humidity control internet network or telephone serv...