background image

ST-POE

16

 

INSTRUCTION MANUAL

  www.securitytronix.com 

www.

nacebrands

.com

Summary of Contents for ST-POE16

Page 1: ...ST POE16 INSTRUCTION MANUAL www securitytronix com www nacebrands com ...

Page 2: ...UMENTATION IN CONNECTION WITH THE USE OF THIS PRODUCT EVEN IF SECURITYTRONIX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES REGARDING TO THE PRODUCT WITH INTERNET ACCESS THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS SECURITYTRONIX SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK HACKER ATTACK VIRUS INSPECTION OR OTHE...

Page 3: ...ance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause har...

Page 4: ...ety regulations of the nation and region Please refer to technical specifications for detailed information Input voltage should meet both the SELV Safety Extra Low Voltage and the Limited Power Source with 100 240 VAC or 12 VDC according to the IEC60950 1 standard Please refer to technical specifications for detailed information Do not connect several devices to one power adapter as adapter overlo...

Page 5: ...roperly secured to a rack or shelf Major shocks or jolts to the unit as a result of dropping it may cause damage to the sensitive electronics within the unit Use the device in conjunction with an UPS if possible Power down the unit before connecting and disconnecting accessories and peripherals A factory recommended HDD should be used for this device Improper use or replacement of the battery may ...

Page 6: ... purchasing our product If there is any question or request please do not hesitate to contact the dealer The figures in the manual are for reference only This manual is applicable to the models listed in the following table Model ST POE16 ST POE24 ...

Page 7: ...on 11 2 1 Installation Notes 11 Safety Alert 11 Environmental Requests 11 Tools 12 2 2 Installation 12 Rack mounting 12 Desktop mounting 13 2 3 Grounding 14 With grounding bar 14 Without grounding bar 15 Chapter 3 Physical Connection 17 3 1 Connect to RJ45 Ports 17 3 2 Connect to SFP Combo 18 3 3 Check the Cabling 19 3 4 Connect to Power Supply 19 Appendix Technical Specifications 20 ...

Page 8: ...tput is 230W ST POE16 and 370W ST POE24 By using Cat 5 twisted pair the device can provide data and power for APs IP cameras IP phones and other PoE devices Moreover with using Cat 5e Ethernet cable and enabling extend mode the transmission distance of data and power can be as long as 250m 1 2 Package Contents Open your package and check the followings Item Number Switch 1 Power cord 1 Footpads 4 ...

Page 9: ...nd powers the PD properly Blinking The PoE output of the corresponding port exceeds 30W Off The corresponding port is no PoE power output or no PD connected POE MAX Solid The PoE power gets to the alarm value and the available PoE power is less than 6W Blinking The PoE power gets to the maximum Off The PoE power works properly and the available PoE power is more than 6W G1 G2 Solid The correspondi...

Page 10: ...x of the remote device to be Auto Negotiation 2 If Extend mode is disabled the transmission distance of PoE powering and data is up to 150m by using Cat 5e or better Ethernet cable RJ45 ports SFP combos Model 10 100Mbps RJ45 ports 10 100 1000Mbps RJ45 ports 1000Mbps SFP combos G1 F G2 F ST POE16 16 2 2 ST POE24 24 2 2 Note that 1 Ports 1 8 are with high priority by default which take advantage ove...

Page 11: ...24 as a guide Figure 1 2 ST POE24 Power Socket Used for connecting the included power cord for power supply Please use the included power cord to connect the device to power supply Grounding Terminal Used for connecting the grounding cable for lightning resisting The grounding details refer to Section 2 3 Grounding ...

Page 12: ...om the power supply if cleanup is required for the case Position the device away from strong current or electro magnetic fields Cautions There is a seal covering one of the screws in the case of the device In the event a repair is needed please keep this seal intact The user should not break the seal without permission of the service agent to avoid a warranty voiding situation Environmental Reques...

Page 13: ...ctions below The rack desktop is stable and sturdy enough Place the device in a clean dry and well ventilated environment Keep at least 10cm free on all sides for cooling Do not place any heavy or big size object on the device Keep at least 1 5cm vertical distance between each device while installing it an equipment rack Tools Things you ll need but should be prepared by yourself Figure 2 1 Instal...

Page 14: ...e 2 2 L shaped bracket installation 3 Adjust the device to a nice height and fix the device to the rack with screws self prepared Shown as below Figure 2 3 Fix to the rack Desktop mounting Also you can install the device on a desktop 1 Place the device bottom on a stable and flat desktop 2 Paste the four footpad stickers to the corresponding four corners of the device bottom ...

Page 15: ...ease select the proper method to ground your device With grounding bar If a grounding bar is available at the installation site follow either of the two installations to ground the device A Connect to the Grounding Bar Directly 1 Connect one end of the grounding cable to the binding post on the grounding bar 2 Connect the other end of the grounding cable to the grounding terminal and fix the screw...

Page 16: ...e Cautions Connect the grounding cable to the earth ground system in the equipment room Do not connect it to a fire main or lighting fixture Without grounding bar If there is no ground bar but earth ground nearby and the grounding body is allowed to be buried follow below steps 1 Bury an angle steel or steel pipe 0 5m into the earth 2 Weld one end of the grounding cable to the angle steel or steel...

Page 17: ...ding body are not available an AC powered Ethernet switch can be grounded using the PE Protecting Earth wire of the AC power supply Figure 2 8 Ground with 3 core AC power cord Cautions Make sure that the PE wire of the AC power supply has been well grounded at the side of the power distribution room or AC power supply transformer ...

Page 18: ...IEEE 802 3at PoE supply and the PD can be wireless AP IP phone or IP camera etc By default PoE features of Ports 1 16 24 are enabled Figure 3 1 RJ45 port connection Note that 1 Cat 5e or better Ethernet cable is recommended As each RJ45 port supports MDI MDIX auto negotiating either parallel or crossover cable is available 2 The device supports dynamic PoE supply Namely the device will power the P...

Page 19: ...mbo 1 Insert your optical module into the SFP port G1 F G2 F Figure 3 2 Insert optical module 2 Insert the remote optical fiber to the module correctly RX fiber into the port labeled RX on the module and TX fiber into the TX Figure 3 3 Insert optical fiber ...

Page 20: ...orts cablings and grounding cable are correctly connected If there is outdoor cabling connect a lightning protector to the cable before you plug the cable into the port Figure 3 4 Lightning protector connection Ethernet cable Grounding terminal Lightning protector Grounding cable Outdoor cabling 3 4 Connect to Power Supply Please use the included power cord for power supply Figure 3 5 Power connec...

Page 21: ...Lightning proof Ranking RJ45 port lightning proof 4KV Power source lightning proof 6KV Power Input 100 240V AC 50 60Hz Physical Environment Operating Environment Temperature 32 F 104 F Humidity 10 90 RH non condensing Storage Environment Temperature 40 F 158 F Humidity 5 90 RH non condensing Transmission Speed Ethernet 10Mbps Half Duplex 20Mbps Full Duplex Fast Ethernet 100Mbps Half Duplex 200Mbps...

Page 22: ...rdware riot war invasion act of foreign enemies hostilities regardless of whether war is declared civil war rebellion revolution insurrection military or usurped power or confiscation terrorist activities nationalization government sanction blockage embargo labor dispute strike lockout or interruption or failure of electricity air conditioning or humidity control internet network or telephone serv...

Reviews: