TROUBLESHOOTING

a.

No picture  after  applying  power  – (i)  check  all  plugs  and  cables  are securely
connected  to the  proper connectors;  (ii)  ensure  your  power  supply  is  providing  the
correct voltage and current.

b.

The  picture  has  ripples  – (i)  check  to see  if  the  power  supply  is  experiencing  AC
ripple,  if  so  a filter  may  be  required;  (ii)  determine  if  the  monitor  is  faulty;  (iii)
determine  if  other  peripheral  equipment  is  causing  ripple  and  if  so  make  the
necessary adjustments.

c.

The picture background continuously changes color – a fluorescent lamp’s magnetic
field  may  cause  color  roll,  therefore,  reduce  the  number  of  fluorescent  lamps  or
increase the distance between the camera and the lamps.

d.

The picture appears smeared – (i) the power supply voltage level may be unstable,
therefore,  try  another  power  supply;  (ii)  ensure  the  cables  are correctly  connected
and/or the cables are of the correct impedance.

e.

Other interference may require a SecurityTronix ground loop isolation filter.

f.

Additional troubleshooting assistance can be found on-line at 

www.securitytronix.com

in addition to support from SecurityTronix sales engineers at 

1-

610 429-1821

, option

3

, then option 

2

.