5.  TROUBLESHOOTING 

a.  No  picture  after  applying  power  –  (i)  check  all  plugs  and  cables  are  securely 

connected  to  the  proper  connectors;  (ii)  ensure  your  power  supply  is  providing  the 
correct voltage and current. 

b.  The picture has ripples – (i) check to see if the power supply is experiencing AC ripple, 

if  so  a  filter  may  be  required;  (ii)  determine  if  the  monitor  is  faulty;  (iii)  determine  if 
other  peripheral  equipment  is  causing  ripple  and  if  so  make  the  necessary 
adjustments. 

c.  The picture background continuously changes color –  a fluorescent lamp’s magnetic 

field  may  cause  color  roll,  therefore,  reduce  the  number  of  fluorescent  lamps  or 
increase the distance between the camera and the lamps. 

d.  The picture appears smeared – (i) the power supply voltage level may be unstable, 

therefore,  try  another  power  supply;  (ii)  ensure  the  cables  are  correctly  connected 
and/or the cables are of the correct impedance. 

e.  Other interference may require a SecurityTronix ground loop isolation filter. 
f.  Additional troubleshooting assistance can be found on-line at 

www.securitytronix.com

 

in addition to support from SecurityTronix sales engineers at 1-610-429-1511. 

 
 
 

Summary of Contents for ST-D6003.6 –B

Page 1: ...v1 0 1 14 11 1 INSTALLATION MANUAL ST D6003 6 B or W Indoor Color Dome Camera With CMOS Sensor ...

Page 2: ...ich color high definition stability and resistance to jamming make it attractive for CCTV security applications SPECIFICATIONS ST D6003 6 Specifications Typical 1 Image Sensor 1 3 CMOS Digital Image Sensor 2 Pixels HxV 768x494 3 Scanning System NTSC 4 Horizontal Resolution 600TV Lines 5 Synchronization Internal Negative Sync 6 Minimum Illumination 0 1Lux Color 0 05Lux B W 7 Scanning System Interla...

Page 3: ...era s life and proper operation do not point the camera towards the sun or strong light c Do not install the camera in an environment where the temperature is above 122 F d Do not install the camera near a magnetic field or a high power motor e Do not mount the camera near a radiator or heater f Only use a dry cloth to clean the camera If there is dirt that is difficult to remove wipe gently with ...

Page 4: ... to the camera s power outlet b Connect the camera to the monitor with a 75Ω coaxial video cable c Connect power supply s AC plug to a suitable AC power outlet d Adjust the lens direction according to the required surveillance area and environment Effective Monitoring Area ...

Page 5: ...tments c The picture background continuously changes color a fluorescent lamp s magnetic field may cause color roll therefore reduce the number of fluorescent lamps or increase the distance between the camera and the lamps d The picture appears smeared i the power supply voltage level may be unstable therefore try another power supply ii ensure the cables are correctly connected and or the cables ...

Reviews: