26
4.2
CHIMNEY INSTALLATION INSTRUCTIONS
1.
Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see figure 27).
Use a plumb bob to line up the centre of the holes. The sizes are indicated in table 1 for the floor and
ceiling holes and table 2 (page 28) for the roof holes.
CHIMNEY MODEL
HOLE SIZE
Secure Temp
ASHT+
Nova Temp
16 3/8 in. (416 mm)
AC
:
17 in. (432 mm)
Table 1
From below, install a firestop in each ceiling/floor separation through which the chimney will pass.
At the attic level, install an attic radiation shield from above. (figures 28 & 29).
2.
For Secure Temp
ASHT+
/ Nova Temp
chimneys, place the first chimney length on the fireplace.
To lock it in place, turn ¼ of a turn clockwise. With the AC chimney, you must use a starter section
before installing the first chimney length (figure 30). Continue installing chimney lengths making
sure to lock each length in place.
3.
Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you
reach the desired height, install the roof support. (Refer to instructions included with the support).
For an AC chimney use an universal support AC10SU.
4.
Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch.
(see figures 31 & 32). For sloping roofs, place the flashing under the upper shingles and on top of
the lower shingles. Nail the flashing to the roof, using roofing nails.
5.
Place the storm collar over the flashing, and tighten it with the bolt supplied. Finally, seal the joint
between the storm collar and the chimney, using silicone caulking.
6.
Install the chimney cap.
Figure 27
Figure 28
Figure 29