background image

Hexnut Bolt

Door Spacer

Rubber

Washer

Armature

Screw

Call 1-775-355-5625

For Technical Assistance

550 Vista Blvd., Sparks NV 89434

www.securitron.com/vista

Product Power Input Wiring:

For VM1200 and VM600 Series, this can be wired directly onto the PCB terminal 

block that has label + and -. 

For VM300 Series, these are flying leads. Red wire is + and black wire is -.

(NO NEED TO REMOVE COVER PLATE FOR VM300)
Wiring for models with MBS:

For VM1200 and VM600 Series, the signal is given out from SPDT relay. Wiring can 

be done through PCB 3-block terminal labels NC, COM, and NO.

For VM300 series has 3 flying leads. Black wire is COM, green wire is NO and white 

wire is NC.
Wiring for models with DPS:

For VM1200 Series, the signal is given out from the 3 block terminal (NC, COM, 

NO) that is labeled Reed on the PCB. For VM600 Series, there are 3 flying leads. 

Black wire is COM, green wire is NO and white wire is NC.

Product Specification:
• Holding Force - VM1200 Series: 1200 lbs (544 Kg)

 

           VM600 Series: 600 lbs (272 Kg)

 

           VM300 Series: 300 lbs (136 Kg)

• 12 & 24 volts DC operation (selectable).

   Note:

 Factory default setting is 12VDC.

Product Type:

•  Besides unmonitored version, all VM Series locks have either magnetic bond    

    sensor (MBS) or door position switch (DPS) or both. 

•  For VM1200 and VM600 Series, magnetic bond sensor uses hall effect  

    

sensor. For VM300 Series, uses change-over reed switch sensor.

•  For VM1200 and VM600 Series, door position sensing uses change-over reed

    switch sensor.

VM1200 and VM600 Series with MBS:
• For VM1200 and VM600 Series, the LED operation color can be field set. The

   colors can be reversed simply by reversing the 2 pin plug connection on the PCB.

• There is no LED or DPS available on the VM300 Series

• The factory default setting is as follows:

     

LED indicator off 

(No power to the magnet)

     

LED indicator red 

(Power on magnet, door open)

     

LED indicator green     (Power on magnet, door closed)

• 

Note:

 where the Maglock has both MBS and DPS, the LED

   indicates as per the MBS model.

     

Product Dimensions (L x W x H):
   VM1200 Series - 10-1/2” x 2-7/8” x 1-9/16” [266mm x 72mm x 40mm]

   VM600 Series - 9-3/8” x 1-7/8” x 1-1/6” [238mm x 48mm x 26.5mm]

   VM300 Series - 6-11/16” x 1-5/8” x 7/8” [170mm x 41.4mm x 22.8mm]

Installation Requirements:
• Adjust onboard PCB shunt settings for correct operating voltage prior to  

   applying power to the EML.

   

   For 12 volts two shunts must be installed:

       

- First shunt joining pins 1 & 2

     

- Second shunt joining pins 3 & 4.

   

  For a 24 volt system only one shunt is required, joining pins 2 & 3.

1

2

VM300, VM600 & VM1200 Series Maglock Installation Instructions

PRODUCT INFORMATION

PRODUCT INSTALLATION AND WIRING

3

STANDARD MOUNTING METHOD

• Use the supplied template  

   to determine the correct  

   location and size of    

   mounting holes for both    

   the door and frame   

   header. Ensure that the  

   door opens away from the  

   Maglock. In the case of a  

   single door, the Maglock is

   positioned as close as  

   possible to the vertical  

   section of the door jamb.

• Loosely install the mounting plate using two of the supplied philips

   head mounting screws in the elongated slots. Attach the Maglock to the

   mounting plate.

ADJUST POSITION OF MAGNET RELATIVE TO THE ARMATURE

• Ensure the armature and magnet are aligned. Adjust the

  mounting plate to suit and then drill the appropriate sized

  holes in the door header for the remaining attachment screws.

• Align the armature plate on

   the door using sight or the

   template supplied.
• Mark and drill holes then

   mount the armature to

   the door. Make sure that

   the armature plate is not

   over tightened and that it is

   installed as shown in the

   following diagram. The

   armature plate must be free

   to self align with the door.

 

Mounting Plate

MOUNTING ARMATURE ON DIFFERENT DOOR TYPES

HOLLOW CORE

DOOR ENLARGE

HOLE TO 5/8in

 [16mm]

SOLID CORE

DOOR ENLARGE

HOLE TO 15/32in

 [12mm]

REINFORCED 

DOOR

TAP 1/4-20 VM600

[M6 X 1.0] 

TAP 5/16-18 

VM1200

 [M8 X 1.25]

Reviews: