SECURECOM SC-F3G User Manual Download Page 2

 

Table of Contents 

1. 

Introduction ..................................................................................................................................... 3 

2. 

Functions ......................................................................................................................................... 3 

3. 

Features ........................................................................................................................................... 3 

4. 

Package Contents ............................................................................................................................ 3 

5. 

Device Configuration ....................................................................................................................... 4 

6. 

Status LED signals ............................................................................................................................ 5 

7. 

Before You Start .............................................................................................................................. 5 

7.1 Monitoring Receiver ...................................................................................................................... 5 

7.2 GPRS/3G SIM Card and APN .......................................................................................................... 5 

8. 

Setting SC-F3G ................................................................................................................................. 6 

8.1 Installing the 3G DATA Setup application...................................................................................... 6 

9. 

Configuring SC-F3G .......................................................................................................................... 6 

9.1 Information and administration area ............................................................................................ 6 

9.2 Module Status ............................................................................................................................... 7 

9.3 Modem and GPRS Settings ............................................................................................................ 7 

9.4 Latest Events.................................................................................................................................. 7 

9.5 Monitoring Station Settings .......................................................................................................... 8 

9.6 Input Settings ................................................................................................................................ 8 

9.7 Communication Event Codes ........................................................................................................ 9 

10. 

Signal Transmission ..................................................................................................................... 9 

10.1 Description of the signal transmission ........................................................................................ 9 

10.2 Signal transmission logic ........................................................................................................... 10 

10.3 Backup PSTN Line operation ..................................................................................................... 10 

11. 

Controlling Output ..................................................................................................................... 10 

12. 

Mounting ................................................................................................................................... 11 

13. 

Technical Details ........................................................................................................................ 13 

 

 

Summary of Contents for SC-F3G

Page 1: ...S SC C F F3 3G G User Manual 1 0...

Page 2: ...DATA Setup application 6 9 Configuring SC F3G 6 9 1 Information and administration area 6 9 2 Module Status 7 9 3 Modem and GPRS Settings 7 9 4 Latest Events 7 9 5 Monitoring Station Settings 8 9 6 In...

Page 3: ...increased by the internal Li Ion battery LI Ion 18650 2600mAh that provides at least 5 hours operation in case the main power supply is lost 2 Functions Alarm control panel signal transmission over 3G...

Page 4: ...for the alarm control panel s TIP RING input Line voltage 48V Loop current 25mA Impedance 300ohm INPUTS IN1 IN2 Contact inputs to DC for transmission of the signal of external switches RELAY OUTPUT R...

Page 5: ...n hook or dialing Blue constant Sending CID signals to the monitoring station 7 Before You Start 7 1 Monitoring Receiver Make sure that the monitoring receiver is equipped with the system that allows...

Page 6: ...ation software is running only on MS Windows 7 operating systems or above 9 Configuring SC F3G USB connection steps 1 Run the 3G_DATA_setup application 2 Connect the SC F3G communicator to the compute...

Page 7: ...Inactive PSTN Line Status of incoming PSTN landline 1 The transmission is stable in case of minimum 30 signal strength If the signal strength is lower than 30 move the device to another place where t...

Page 8: ...mmunicator forwards the signal in case of the alarm system is dialing this number If this field is empty than the communicator forwards the signals independently of the dialed number by the alarm syst...

Page 9: ...s dialing over TIP RING line a preset phone number e g 1111 The communicator detects the dialing and sends back the Handshake signal to the alarm control panel The alarm control panel sends the Contac...

Page 10: ...if the Dialed number by alarm system filed is NOT empty 10 3 Backup PSTN Line Operation If the monitoring stations are unavailable via GPRS 3G network the communicator switches to PSTN line In that ca...

Page 11: ...12 Mounting 1 step Fixing the back plastic back plate 2 step Panel fixing and wiring...

Page 12: ...3 step Releasing the wall fixing screw flipping for the front plastic case fixing and screwing 4 step Wall fixing with plastic cover...

Page 13: ...face to alarm panel contact and voltage type in paralell mode Contact type INPUT to DC external pull down impedance 100 Ohm Voltage type INPUT to DC external voltage trigger treshold 5V max 30V Alarm...

Reviews: