background image

 

Page 14 of 56 

Premier 211 User Manual  

BGX701-075-R03                                                                 

 

8.   

 

LC-ON 1 represents the relay state (ON/ARMED).

 

9.   

 

Supply will be permanently in ON state 

SCC: Not used 

10.  

 

NOT USED

 

11.  

 

NOT USED

 

12.  

 

WAN communication indicator - Indicates presence of 4G/3G/GPRS 

communication modules.

 

13.  

 

Indicates that the meter is paired or ready for pairing with the HAN device

 

14.  

 

Service status mode indicator - Indicates that attention and due service by 

authorised personnel is needed for maintenance e.g. Real Time Clock 

failure. 

 

15.  

 

Phase annunciators - Indicate the presence of supply voltages at the 

respective phase. The annunciators also flash if reverse current is detected 

in any of the phase.

 

 

Table 2: Operations possible through Premier 211 push buttons 

S. No.

 

Function

 

Details

 

1.    Parameter Navigation 

Premier 211 may be configured to display a desired list of parameters. These 

parameters are logically grouped to appear as a different display page, each 

of which is assigned an individual display ID. 

2.    Metrological LED 

configuration  

The metrological LED can be configured to flash on desired energy channel 

using the parameter navigation function.  

Note:  

This is applicable only till midnight cross over, following which, it switches to 

the factory configured settings. The same is applicable for a power 

interruption. 

2.4 

Using the display 

Two modes are available for viewing the displays in the meter: 

 

Push Button Mode 

 

Auto Mode 

 

Summary of Contents for Premier 211

Page 1: ...Page 1 of 56 Premier 211 User Manual BGX701 075 R03 Premier 211 electricity meter with Skyline i 543 033 communication module User Manual BGX701 075 R03...

Page 2: ...E Premier 211 and Skyline i 543 033 are registered trade names of Secure Meters Ltd Other product names are trademarks or registered trade names of their respective owners As part of Secure Meter s co...

Page 3: ...tandards and external certification 21 3 5 Connection terminals 21 4 Functional specifications 22 4 1 Meter operating modes 22 4 1 1 Default mode 22 4 1 2 Credit mode 22 4 1 3 Commissioning mode 22 4...

Page 4: ...4 12 4 UTRN 37 4 12 5 Supply 37 4 12 6 Security 37 4 12 7 Configuration 37 4 13 Communication channels 38 4 14 Meter reading data 38 4 15 Engineering services 39 4 16 Meter diagnostic data 39 5 Commu...

Page 5: ...eters reserve the right to alter some or whole of the specifications mentioned in this document without any prior notice For any queries or clarifications the user is requested to email the Secure Met...

Page 6: ...ter under the following circumstances Irregular maintenance improper installation Imprudence or carelessness during installation Normal or abnormal wear and tear of insulation Accidental contact with...

Page 7: ...eter is regularly exposed to chemical fumes etc When enabling the external antenna always ensure that it has been plugged into the SMA connector under the module To ensure optimal performance of the r...

Page 8: ...g PC FR Poly Carbonate Fire Retardant LCD Liquid Crystal Display LED Light Emitting Diode SMA Sub Miniature version A DIP Demand Integration Period WAN Wide Area Network HES Head end system ID Identit...

Page 9: ...le The Zigbee module connects the communication module with other HAN devices In Home Display IHD Figure 1 Operational scenario with Skyline i 543 033 It has an ANSI optical communication port for loc...

Page 10: ...Page 10 of 56 Premier 211 User Manual BGX701 075 R03 1 2 4 6 5 7 3 2 Product description This section describes the salient features of the product 2 1 Premier 211 main features 10 8 9 11...

Page 11: ...rical signals 7 Sealable Screws These screws facilitate the sealing arrangement necessary after the installation of the meter in the field 8 Meter Base and Front Cover The base or enclosure of the met...

Page 12: ...available on the front cover only for Premier 211 fitted with Skyline i 543 Class index Frequency As per load control variant Meter category code 3 phase 4 wire Rated operating voltage Current rating...

Page 13: ...etails Remark 1 Alpha numeric main value indicator This segment displays the values of pre configured parameters in an interactive mode It also displays the health status of the meter and messages on...

Page 14: ...tors also flash if reverse current is detected in any of the phase Table 2 Operations possible through Premier 211 push buttons S No Function Details 1 Parameter Navigation Premier 211 may be configur...

Page 15: ...rts in auto mode A complete list of sample display screens are shown under Appendix 1 LCD displays 2 4 1 Display types and viewing arrangements Premier 211 uses a Super Twisted Nematic STN type Liquid...

Page 16: ...5 R03 The figure below illustrates the meter display from two different positions Case 1 When the meter display is viewed from a level above the meter Case 2 When the meter display is viewed from a le...

Page 17: ...FR grade V0 Base Opaque PC FR material Communication module cover Opaque PC FR material Terminal cover Opaque PC FR material Secondary terminal block cover Opaque PC FR material Extended terminal bloc...

Page 18: ...ltage 230V 20 Reference current range 5A Ib 20A Imax per phase Frequency 50 Hz 5 Power Factor 0 5 Lag Unity 0 8 Lead as per IEC AS 62053 21 for Active Energy 0 25 Lag Unity 0 25 Lead as per IEC AS 620...

Page 19: ...54 with suction Protective class II 5 Environmental Storage Area The meter is designed for indoor outdoor use in accordance with IEC 60721 3 3 1996 Ideally the meter should be stored and operated in a...

Page 20: ...eter data unless the update involves changing the parameters of such data Information related to load survey transactions events and storage or contents in billing registers are not affected during th...

Page 21: ...al communication module conforms to the following standards Table 4 Standards Electrical requirements AS62052 11 AS62053 22 AS62053 23 NMI M6 1 Environmental EN 60068 2 6 EN 60068 2 75 EN 60068 2 27 E...

Page 22: ...r does not perform any scheduled billing 02 In the Default mode relay always remains in connected state 03 In the default mode the meter logs the load profile data for Total Import Active energy kWh w...

Page 23: ...in meter reading snapshots On meter s display energy is shown in 1 kWh kVArh resolution In load profile data cumulative energy values are displayed in 1K or 0 1K resolution 4 2 2 Rate registers The f...

Page 24: ...Data reliability The consumption of load survey data of a particular load profile is recorded at end of the interval period The meter maintains the configured parameters with a resolution of 10 Wh VA...

Page 25: ...napshot available only on request and not stored in the meter The snapshot data consists of the following information as per its configuration Basic information consisting of the snapshot time last bi...

Page 26: ...ff comprises the following Change of tariff scheme Tariff type TOU seasonal calendar b Price change the meter takes a billing snapshot whenever the prices are revised or changed c Scheduled billing da...

Page 27: ...splayed date and time use local time i e standard time DST offset The tariff rate register switching operation can be configured to use standard or local time Scheduled billing dates always use standa...

Page 28: ...ime set more than 5 SIP including the current SIP In this case the meter invalidates all the upcoming SIP data and logs new values as normal processing Here time set flag will be shown in the 1st SIP...

Page 29: ...configuration related activities locally for a specified time 4 6 Meter mode switching Default operation mode Premier 211 can be switched to the default operation mode via the engineering service UTR...

Page 30: ...se future dated commands can be cancelled or overwritten by a new command 4 7 1 Tariff configuration Premier 211 can be configured with tariff regimes for the following three 3 energy types 1 Import 2...

Page 31: ...direction then no reverse run event is logged 4 7 2 Resetting counters The following counters can be reset via authenticated commands Time set Power On Terminal cover open Main cover open Load limit e...

Page 32: ...rofile data from the SIP of effective day of COT available In the case of change of tenancy the following three situations may occur 1 The tenant has left the premise without notification 2 The tenant...

Page 33: ...command is issued Table 5 Relay action Command received Relay current state Relay action sequence Relay disconnection ARMED Disconnected immediately Relay disconnection ON Disconnected immediately Rel...

Page 34: ...meter cover Removal or restoration of the terminal cover Occurrence and restoration of magnetic tamper Occurrence and restoration of over current UTRN attack relay operation is not allowed If the rel...

Page 35: ...utputs 1 Pulse output 1 is configured on Active import energy with 50 impulse per kWh 2 Pulse output 2 is configured on Reactive import energy with 50 impulse per kVArh 4 12 Detecting and logging even...

Page 36: ...me Sec Restoration Threshold Default Configurable up to Default Configurable up to Reverse Run 60 8 Imax 100 Imax 60 5 Imax 99 Imax Over Voltage 60 106 Vnom 150 Vnom 60 103 Vnom 149 Vnom Under Voltage...

Page 37: ...recorded in the supply log along with the date and time of the occurrence For relay arming the meter records the ARMED to connect reason code too If configured the meter can send alerts for such event...

Page 38: ...upports a maximum data rate of up to 38400 baud It can be used to read consumption data and other information locally This port can be enabled or disabled using a service UTRN 4G 3G WAN module for com...

Page 39: ...Clear event logs Clears the events from selected event logs Security log in not cleared Clear Site ID Clears the site ID vulnerable consumer setting and delayed tariff if any Clear load profile data...

Page 40: ...he meter has to be installed in a location with poor signal strength 5 1 1 Functions of Skyline i 033 Skyline i 543 The communication module has the following interfaces Zigbee Module a Zigbee 2 4 GHz...

Page 41: ...n module cover Skyline i 543 033 Figure 7 Skyline i 033 front cover printings Figure 8 Skyline i 543 front cover printings Barcode for the module serial number Module serial number Module category cod...

Page 42: ...Isolated ground for the communication module 4 GND Isolated ground for the communication module 5 PDD Power Down Signal to the communication module Digital or 100 Hz of mains zero crossing signal 6 Se...

Page 43: ...Active Import YES YES YES 4 Net Active Export YES YES YES 5 Net Reactive Import YES YES YES 6 Net Reactive Export YES YES YES 7 Active Import E1 TOU1 YES YES YES 8 Active Import E1 TOU2 YES YES NO 9...

Page 44: ...Memory failure YES YES YES Meter status Clock invalid YES YES YES Meter status Low battery YES YES YES Meter status Battery failure YES YES YES all status flags are set YES YES YES 18 Tariff Name 8 c...

Page 45: ...Active Import NA YES YES YES 9 Element 1 Active Export NA YES YES YES 10 Element 1 Reactive Import NA YES YES YES 11 Element 1 Reactive Export NA YES YES YES 12 Element 2 Active Import NA YES YES YES...

Page 46: ...High Resolution YES YES YES 23 Net Reactive Export High Resolution YES YES YES 24 Gross Active Import NA 25 Gross Active Export NA 26 Net Element 1 Active Import Accessed from grid NA 27 Net Element...

Page 47: ...Good YES YES YES Meter status NVM Memory failure YES YES YES Meter status Clock invalid YES YES YES Meter status Low battery YES YES YES Meter status Battery failure YES YES YES all status flags are s...

Page 48: ...S YES YES Permit joining ON YES YES YES No communication with HUB YES YES YES 9 IDLE YES YES YES Attempt going on YES YES YES Connected YES YES YES No Power YES YES YES No communication with HUB YES Y...

Page 49: ...kyline i 543 YES YES YES 15 WAN antenna type YES YES YES Page 3 Instantaneous Parameters 1 Page number of the current displayed page YES YES YES 2 Frequency YES YES YES 3 Scaling of the metrological L...

Page 50: ...S 11 Line Current Phase 1 YES YES YES 12 Line Current Phase 2 YES YES YES 13 Line Current Phase 3 YES YES YES 14 Active Power Phase 1 YES YES YES 15 Active Power Phase 2 YES YES YES 16 Active Power Ph...

Page 51: ...fier shows IP for Import 1 represents element YES YES NO 5 Active Export Rate register Price 03 represents Act Rate Register 09 00 represents Act Rate price Identifier EP shows export YES YES NO 6 E2...

Page 52: ...erating mode of the meter Followed by NO YES NO NO NO YES Displays customer s Current Consumption 3 Using Now This is consumption since last billing Header YES YES NO This is for consumption since las...

Page 53: ...button for connecting the main supply Further press left button to connect NA 2 Press right button to confirm YES YES YES Load Limit Display 1 High Load 90 of over load threshold YES YES YES 2 Over Lo...

Page 54: ...Page 54 of 56 Premier 211 User Manual BGX701 075 R03 Notes...

Page 55: ...BGX701 075 R03 Premier 211 User Manual Page 55 of 56 Notes...

Page 56: ...962 840048 f 44 1962 841046 Secure Meters Australia Pty Ltd 258 Darebin Road Fairfield VIC 3078 Australia p 61 3 9485 6000 f 61 3 9485 6099 Advanced Energy Monitoring Systems Ltd South Bristol Busines...

Reviews: