background image

SWITCHPLATE INSTALLATION DIAGRAM

Mounting 

Plate

Reader 

Housing

Mounting 

Surface

¿

¿

Use appropriate 

Fastener

¿

Use supplied 

screw

¿

3/4” diameter 

through hole 

for cables. 

¿

¿

¿

3.28

RADIO KEY

®

 Installation Instructions

INSTALLATION STEPS FOR RK-WM, RK-100M 
and RK65K:

1.

Drill holes as needed per
installation diagram shown to
the left.

2.

Feed cable through 3/4” hole.

3.

Attach reader to any fl at surface
with two #6 screws.

4.

Snap label insert into front of
reader to cover screws.

WIRING CONNECTIONS

RK100M, RK-65K & RK65KS

RK-WM & RK-WS

WIRE 

COLOR

STANDALONE WIRING 

CONNECTIONS

WIEGAND OUTPUT 

WIRING CONNECTIONS

WIRING CONNECTIONS

RED

5-14 VDC +

5-14 VDC +

5-14 VDC +

BLACK

GROUND --- 

GROUND --- 

GROUND --- 

YELLOW

LATCH RELAY

NOT NEEDED

BUZZER INPUT (1)

BLUE

LATCH RELAY

NOT NEEDED

HOLD

ORANGE

REMOTE OPEN (2)

GREEN LED INPUT (3, 1)

GREEN LED INPUT (1)

BROWN

REMOTE OPEN (2)

RED LED INPUT (3, 1)

RED LED INPUT (1)

GREEN

NOT NEEDED

DATA-0

WIEGAND DATA-0

WHITE

NOT NEEDED

DATA-1

WIEGAND DATA-1

( 1 )   C o n n e c t   t o   G R O U N D   t o   a c t i v a t e

( 2 )   I n p u t   P r o g r a m m e d   f o r   R e m o t e   O p e n

( 3 )   I n p u t   P r o g r a m m e d   f o r   L E D / B e e p e r   C o n t r o l

INSTALLATION STEPS FOR RK-WS, RK65KS:

1.

Drill holes as needed per installation
diagram shown to the left.

2.

Feed cable through 3/4” hole.

3.

Attach the mounting plate to
the mounting surface with the
appropriate fasteners.

4.

Attach the housing to the mounting
plate by inserting the two tabs inside
the top of the housing into the two
slots at the top of the mounting
plate.

5.

Secure by installing supplied screws
into the hole at the bottom of the reader.

6.

Connect cable per wiring diagram shown below.

3.50

1.60

Label Tabs 

Insert Here

LED

¿

¿

¿

¿

¿

¿

OUTPUT RELAY

REMOTE OPEN

Note:  Use separate power supplies for electric lock 

and for access control unit. 

TYPICAL INSTALLATIONS 

STANDALONE READERS 

(RK-65K/RK65KS/RK100M)

LOCK 

POWER

SUPPLY

12 

+

STRIKE OR 

MAG LOCK

NORMALLY OPEN SWITCH 

YELLOW

BROWN

ORANGE

BLUE

RED

BLACK

MOV

μ

POWER

SUPPLY

READER

MULLION INSTALLATION DIAGRAM

1.0”

l

l

l

l

1.3”

Use appropriate 
#6 Fastener

3/4” Diameter through 
hole for cable and 
buzzer. 

l

l

3321906   6356

¿

3.20

4.50

¿

¿

¿

Reviews: