E)   REPLACING THE BATTERIES

As soon as the symbol depicting the battery condi-
tion indicates „almost empty“, the operator is also
warned 

Please replace batteries!

 each time the lock

is operated. We recommend you heed the advice
and change the batteries! The lock can only be
unblocked a further, approximately, 50 times. Please
note that none of the number codes can be changed
until a set of fresh batteries has been fitted. To
change the batteries, lift off the cover of the battery
compartment with the tip of a screwdriver. Fit three
leak-proof, type Mignon LR6, AA, alkaline batter-

ies, paying attention to the correct polarity. Dispose of the old batteries in accordance with anti-pollution legislation!

G)  ADDITIONAL LOCK SETTINGS

For detailed information about the additional lock functions, please check the CD-ROM supplied with the lock. These

functions cover:

- Time functions----------------- Set time

- Set date

- Administrator functions

- Define number of digits of secret codes
- Reorganize
- Assignment and administration of user codes

- Read out list of operations

- Display lock information

F)  BACKUP MODE

The advantage of the fully redundant design is that the lock can be switched over from standard to backup mode in case
of a failure of the standard lock system. To open the lock after switching to backup mode, enter the code previously
assigned in the backup mode. However, until the system administrator has changed the factory-set administrator code for
the backup mode, i.e. 1 2 3 4 5 6 7, to the secret code of his choice, the lock will send out the warning 

Backup cde still

factory setting 

whenever it is switched on

.

IMPORTANT SAFETY ISSUE !

When preparing the lock for operation for the first time, change the factory-set administrator code 1 2 3 4 5 6 7
of the backup system to the secret code of your choice. Failing this, the lock can be opened by anybody knowing
the factory setting whenever it is in backup mode.

Opening the lock backup mode

1. Press 

On/Enter

. Next, press 

Function 

key to enter the menu of the setting mode. Above the 

“1” 

and 

“2” keys

 you

will see the symbols for navigating through the menu (up or down). The first item to appear is the menu for 

Code

change.

2. Using keys 

“1” 

and 

“2”

, go to 

Mode select

. To select, press 

On/Enter

.

3. Using keys 

“1” a

nd 

“2”

, go to sub-item 

Reserve mode

. To select, press 

On/Enter

. Using the 

Function 

key, return

to the point where you are requested to enter a code. After keying in any code entered in the backup mode, the lock
is now ready for opening (the next time the lock is started up normally will automatically be in the standard mode).

Selecting a different language

1.

Having entered the setting mode, use keys 

“1” 

and 

“2” 

to go to the field 

Language/Sprache 

in the menue (factory

setting when the lock is installed the first time is 

German (deutsch)

.

 

Select by pressing the 

On/Enter 

key.

2.

Use keys 

“1” 

and 

“2” 

to go to the language of your choice. Select the new language by pressing the 

On/Enter 

key.

From now on, all messages will appear in the language of your choice. To leave the present menue field in the setting
mode, press the 

Function 

key whenever you see the symbol 

“<“ 

above the key. After leaving the setting mode, the

lock is again ready for clearing. The operator is prompted to enter a valid secret code in the language of their choice.

Summary of Contents for SELO-C

Page 1: ...lock automatically switches itself off for safety reasons The opening procedure has to be started over Once data have been stored numerical codes time frame and user entries not even a power failure will delete them Thelockisoffullyredundantdesign Thismeansthatallelectricalcomponentswhicharecrucialtotheproperfunctioning of the lock come in pairs In the unlikely event of the primary system breaking...

Page 2: ...ode entering key 5 once to complete select ing the figure 2 as one of the figures of the secret code Clearing the lock 1 Press On Enter When the lock is ready for operation you will be asked to enter the code eight seconds after the status of the opening counter is displayed You can abort the opening counter indication by pressing any number key 2 Now enter the 7 or 8 digit numerical code factory ...

Page 3: ...er you see the symbol above the key After leaving the setting mode the lock is again ready for clearing The operator is prompted to enter a valid secret code Changing an existing user code 1 Assoonasyouenterthesettingmode thecursorwillautomaticallygotoCodechange Toselect presstheOn Enter key 2 Next the administrator and the various users are depicted on the display with the administrator in first ...

Page 4: ...he warning Backup cde still factory setting whenever it is switched on IMPORTANT SAFETY ISSUE When preparing the lock for operation for the first time change the factory set administrator code 1 2 3 4 5 6 7 of the backup system to the secret code of your choice Failing this the lock can be opened by anybody knowing the factory setting whenever it is in backup mode Opening the lock backup mode 1 Pr...

Reviews: