NUMBER LOCK  WITH 1 MILLION GENUINE

SETTING CONFIGURATIONS

Operating Instructions for Electronic Lock

E2000 with Opening Delay (Version 5.3)

Electronic lock E2000 with opening delay allows you to either set the lock for immediate access after entering the correct

numerical code, or for delayed access after a pre-set waiting period.

OPENING THE SAFE OR STRONGROOM

1. Press EIN/ON key.

2. After a short, high-pitched signal tone, key-in the numerical code (factory setting: 1 2 3 4 5 6).

3. Press ENTER key - you will hear the short, high-pitched signal tone again. A short, low-pitched signal tone indicates

that you entered the wrong code. If the opening delay is set to 0 (zero) minutes (factory setting), please proceed with

step 6.

4. Wait for the set opening delay to lapse. During the waiting time, the safe cannot be opened. The end of the opening

delay is indicated by short, high-pitched signal tones (lasting 30 seconds).

5. Press ENTER key before the sounding of the signal tones ceases and re-enter the valid numerical code. Complete

by pressing the ENTER key.

6. Open the lock by the lock handle by turning it a half turn.  The electronics will switch itself off automatically after

5 seconds.

7. Now open the door by turning the door handle.

SECURING THE SAFE OR STRONGROOM

If it should only be possible to open the safe or strongroom by entering the numerical code, the door and lock handles

have to be turned back in their original position (first lock the door, then the lock).

LOCKING THE SAFE OR STRONGROOM

The safe or strongroom is locked by turning the door handle.  It can then be opened without re-entering of the numerical

code.

            REMARKS

         -  After keying-in a wrong number, the number combination can be deleted by pressing the EIN/ON key.  After that

the opening procedure can be repeated.

         -  After keying-in the wrong number combination three times in a row, the electronic system blocks the safe for five

minutes. Following that the electronic system blocks the safe for a further twenty minutes, if the entered number

is wrong again (manipulation security). During this waiting time the safe cannot be opened, even if the correct

combination is keyed-in. The end of the blocking time is indicated by two short, high-pitched signal tones.

         -  If more than 30 seconds lapse between keying-in two numbers, the electronic system will switch itself off for

security reasons. The opening or number coding process will then have to repeated from the beginning.

         -  The stored data are not lost in the event of a power failure.