Zone bypass
],
, ... or , and ,
B
!
BY
B
!
BY
B
!
BY
B
!
BY
PIN:
PIN:
PIN:
PIN:
0
0
0
0
9
WXYZ
9
WXYZ
9
WXYZ
9
WXYZ
####
ENT
ENT
ENT
ENT
Arming and disarming of security barrier, “Pre-Alarm” mode
Partial arming
, [Pre-Alarm], ... ,
1
1
1
1
4
GHI
!
4
GHI
!
4
GHI
!
4
GHI
!
ENT
ENT
ENT
ENT
PIN:
PIN:
PIN:
PIN:
Bypassing zone
Abort arming
For selection aborting, also arm procedure aborting the system SECOLink has the key. If the exit delay is
in process and you want to abort arming, press the key and enter PIN code.
CLR
CLR
CLR
CLR
CLR
CLR
CLR
CLR
Arming system with troubles
01:44
1
0-26
+25°C
2
Short user manual
Intruder alarm system
KM2
4, KM24A
keypad
KM2
4, KM24A
keypad
This is universal way of arming, which enables to arm selected partition in desired arming mode.
Example: Only the first partition is armed. This kind of arming is available in
2-storied house
, when at night
the ground
floor isn’t used
, all sensors of this partition are armed. When somebody opens doors will be an
entry delay.
armed
armed
wi ll be
wi ll be
System
System
Press
key
to select arming
mode
.
For partial arming press
... keys
.
1
1
1
1
4
GHI
!
4
GHI
!
4
GHI
!
4
GHI
!
System will be armed.
Press
key.
Away
Away
Press [ENT] to arm
Press[ ] to select mode
Press [1]..[4] to select
part.
Arming
Arming
READY TO ARM
READY TO ARM
01:44
1st Floor
2nd Floor
1
0-26
+25°C
2 nd Floor
2
1
1st Floor
Sritys
Using ... keys check all
partitions which have to be armed.
Press key to confirm the
decision.
1
1
1
1
4
GHI
!
4
GHI
!
4
GHI
!
4
GHI
!
ENT
ENT
ENT
ENT
Zon
es
Zon
es
Zon
e
s
Zon
e
s
Hallway
Hallway
Hallway
Hallway
Kitchen
Kitchen
Kitchen
Kitchen
Bedroom
Bedroom
Bedroom
Bedroom
Smoke detector
Smoke detector
Smoke detector
Smoke detector
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
Door
Door
Door
Door
Zone isn’t violated
Zone is violated
Zone is bypassed temporary
Zone is bypassed
permanently
Microwave or infrared rays based security barriers, also outdoor PIR detectors, which are connected to the
system, can be armed by “Pre-Alarm” mode. The system will sound an alarm (without sending alarm
message to Central Monitoring Station), when someone traverses this electrical barrier. The “Pre-Alarm”
mode can be turned on and turned off by marking/unmarking partitions with ... keys or by selecting
partitions with , keys and marking/unmarking with , keys.
1
1
1
1
4
GHI
!
4
GHI
!
4
GHI
!
4
GHI
!
####
Bypassing a zone allows you to leave a door or window open while still arming the rest of your security
system. Bypass procedure can be made:
There are two different bypass types: temporal or permanent. First is used for one arming and disarming cycle, second – until
the user unbypass the zone. Enter the zone number you would like to bypass. THIS MUST BE A TWO DIGIT NUMBER
(for the first zone – 01, for second – 02 and so on). The zone will be marked by "x". The last number should be pressed and
held for 2 sec to bypass the zone for a long time (permanently). The zone will be marked by capital "X". When all zones are
marked press the key. The same actions can be performed by selecting the zones with the keys or and by
marking/unmarking with the key (short press – temporal zone bypass, long – permanent zone bypass).
ENT
ENT
ENT
ENT
####
EU standards unexpect
using of the system, which has troubles. When key is backlighted with green
color, the arming is impossible in the ways, which were described earlier. It is necessary immediately
eliminate troubles, also inform CMS and company, which had installed the system.
The system detects troubles in own modules, also it detects and other common troubles, like
230V
disappearance in AC line, disconnected phone line because of repair
, battery discharge. In exceptional
cases is possible to bypass the troubles for a short time and arm system as usual.
It can be done this way:
CLR
CLR
CLR
CLR
Press the key once – message about the trouble will be shown on the display. Press the key again –
the key backlight starts to blink fast. The blinking duration is
30
seconds. During this time
is possible to make
usual arming procedure.
CLR
CLR
CLR
CLR
CLR
CLR
CLR
CLR
Sys. Trouble
Sys. Trouble
AC Loss