ENFORCER Multi-Function Timer/Counter 

6

 

SECO-LARM U.S.A., Inc. 

Sample Applications (Continued): 

5.

 

Use the "Up" or "Down" buttons while viewing the display to set the relay output delay duration 
00:00 to 99:99 (for 0~9,999 seconds) after the trigger input and press "Enter" to confirm.   

6.

 

The buzzer will sound 3 times and the display will flash through the settings in order (00:04 for 
Mode 4, relay output type, time unit, relay output duration, delay duration) and automatically 
exit the programming mode returning to display the mode chosen (00:04). 

Mode 5: Timed Pulse Relay Output  

Mode 5 is similar to "Mode 4" except that the trigger input will produce a timed pulse relay output 
(alternating "ON" for 0.5 seconds and "OFF" for 0.5 seconds repeatedly) and there is no delay. 
This mode can be set to trigger the relay for a set duration starting from when the input trigger 
signal is received or when the trigger input is released, or to toggle a relay on or off. The process 
can also be interrupted using a manual reset button (see Fig. 4, pg. 5 for sample wiring diagram). 

 

1.

 

After entering programming mode, use the "Up" or "Down" buttons to set the display to 00:05 
to choose "Mode 5" and press "Enter" to confirm.  

2.

 

For the remaining programming, continue with steps 2 through 4 of the 

Mode 4: Timed Relay 

Output

 above.  

3.

 

After completing step 4, the buzzer will sound 3 times and the display will flash through the 
settings in order (00:05 for Mode 5, relay output type, time unit, relay output duration) and 
automatically exit the programming mode returning to display the mode chosen (00:05). 

Mode 6: Counter (Count up / Countdown) 

The counter mode tracks the number of input 
triggers. It can count up from 0 (to a maximum of 
9,999 times), showing the current progress on 
the display (Note that there is no relay output or 
LED/buzzer notification for count up). Or, it can 
trigger the output relay/notification LED and/or 
buzzer for one second (or an external 
notification device) after a set number of trigger 
inputs, showing the countdown on the display. 
After either count is complete, counting will stop 
until manually reset using an external reset 
button. A manual reset button can also be used 
to reset the count at any time (see Fig. 5 for 
sample wiring diagram).  

1.

 

After entering programming mode, use the 
"Up" or "Down" buttons to set the display 
to 00:06 to choose "Mode 6" and press 
"Enter" to confirm. 

Fig. 5 – Modes 6 and 7 

N.C. 

Relay output     COM       

N.O. 

Reset input (N.O.

)


+

Trigger input 

(N.O.+ or N.C.–)

Power input

 

 – 

 + 
 
 – 

Reset 

button 

(optional, 

N.O.–) 

12~24VDC 

Power 

Supply 

Trigger to 

be timed or 

counted 

(N.O.+) 

*Notification (internal LED/Buzzer or external) only 

for countdown counter/timer. 

 

External 

notification 

(optional)*

 

Summary of Contents for SLI ENFORCER SA-025MQ

Page 1: ...y output timed pulse relay output input counter input timer Mode and last programmed settings remain after power loss Timer can be set from 1sec 11h 59min Can be set to trigger notification red LED an...

Page 2: ...perature 40 158 F 40 70 C Dimensions 211 16 x11 8 x31 4 68x28x83 mm Weight 2 8 oz 79 2g Specifications Introduction Parts List Overview Cover Removed Operation Notes 31 4 83 mm LED Display 211 16 68mm...

Page 3: ...y see Fig 2 for sample wiring diagram Warning Users and installers of this product are responsible for ensuring this product complies with all national state and local laws and statutes Sensors to det...

Page 4: ...lay to set the time you want to set as the maximum time between guard visits from 00 01 to 59 59 minutes seconds Press Enter to confirm 3 The buzzer will sound 3 times and the display will flash throu...

Page 5: ...y duration and the relay output duration The process can also be interrupted using a manual reset button see Fig 4 for a sample wiring diagram 1 After entering programming mode use the Up or Down butt...

Page 6: ...e with steps 2 through 4 of the Mode 4 Timed Relay Output above 3 After completing step 4 the buzzer will sound 3 times and the display will flash through the settings in order 00 05 for Mode 5 relay...

Page 7: ...r notification for the count up timer The countdown timer shows the time remaining on the display and triggers the output relay notification LED and buzzer or an external notification device for one s...

Page 8: ...ght 2018 SECO LARM U S A Inc All rights reserved WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for one 1 year from the date of s...

Reviews: