ENFORCER Twin Photobeam Detectors 

4

 

SECO-LARM U.S.A., Inc. 

Run a cable from the alarm control panel to the photobeam sensor. If burying the cable is 

required, make sure to use electrical conduit. Shielded cable is strongly suggested. See Table 1 

for maximum cable length. 

The photoelectric beam lens can be adjusted horizontally ±90°, and vertically ±5° (see fig. 2). 
This allows much flexibility in terms of how the transmitter and receiver can be mounted.  
See fig. 3.  

Install at a distance of 32" to 39" (80 to 100 cm) above the ground for most situations. See fig. 3. 

Typical Installation:  

Table 1: Cable Length  

Model E-960-D90Q  E-960-D190Q E-960-D290Q E-964-D390Q 

Wire 

Size 

12V  24V  12V 24V 12V 24V 12V 24V 

AWG22 

0.33mm

0.0005in

2

 

320m 

1,050ft 

2,800m 

18,000ft 

280m 

920ft 

2,400m 

7,870ft 

200m 

660ft 

1,600m 

5,250ft 

110m 

390ft 

900m 

2,950ft 

AWG20 

0.52mm

0.0008in

2

 

550m 

1,800ft 

4,800m 

15,750ft 

450m 

1,480ft 

4,200m 

13,780ft 

350m 

1,150ft 

3,000m 

9,840ft 

170m 

560ft 

1,400m 

4,590ft 

AWG18 

0.83mm

0.0013in

2

 

800m 

2,600ft 

7,200m 

23,620ft 

700m 

2,300ft 

6,200m 

20,340ft 

500m 

1,640ft 

4,200m 

13,780ft 

250m 

820ft 

2,200m 

7,220ft 

AWG17 

1.03mm

0.0016in

2

 

980m 

3,190ft 

8,800m 

28,870ft 

850m 

2,790ft 

7,600m 

24,930ft 

590m 

1,940ft 

5,200m 

17,060ft 

310m 

1,020ft 

2,600m 

8,530ft 

 

Note (1):

 

Max. cable length when two or more sets are connected is the value shown in 

Table 1 divided by the number of sets. 

Note (2):

 

The power line can be wired to a distance of up to 3,300ft (1,000m) with AWG22 
(0.33mm

2

) telephone wire. 

Wiring the Transmitter – Wall Mount:  

3.

 

If the sensor wiring is run along the surface 
of the wall – There are two plastic 

knockouts on the back of the sensor unit, 

one on top and one on bottom. Break out 

the appropriate knockout, and pull the 
wiring through the knockout. Then run the 

wiring through the hole near the top of the 

sensor unit so it comes out the front. Using 

two of the included mounting screws, attach 
the mounting plate to the wall. Then 

reattach the sensor unit to the mounting 

plate, connect the wires, and snap on the 

cover. See fig. 6. 

1.

 

Remove the cover. Remove the screw under 
the lens unit in order to detach the mounting 

plate. See fig. 4. 

2.

 

If the sensor wiring comes from inside the 

wall – Break a hole in the mounting plate’s 
rubber grommet, and pull the cable through 

the grommet’s hole. Then run the cable 

through the hole near the top of the sensor 

unit so it comes out the front. Using two of the 
included mounting screws, attach the 

mounting plate to the wall. Then reattach the 

sensor unit to the mounting plate, connect the 

wires, and snap on the cover. See fig. 5.

 

Running the Cable: 

Summary of Contents for SLI Enforcer E-960-D190Q

Page 1: ...am Detectors Manual Model Outdoor Range Indoor Range E 964 D390Q 390 ft 120m 790 ft 240m E 960 D290Q 290 ft 90m 590 ft 180m E 960 D190Q 190 ft 60m 390 ft 120m E 960 D90Q 90 ft 30m 190 ft 60m Multi frequency version ...

Page 2: ...reliable perimeter security minimizing false alarms from falling leaves birds etc Lensed optics reinforce beam strength and provide excellent immunity to false alarms due to rain snow mist etc Weatherproof sunlight filtering case for indoor and outdoor use Non polarized power inputs Automatically adjusts beam strength to compensate for different weather conditions Automatic input power filtering w...

Page 3: ...nto the beams Therefore do not mount near trees bushes or other leafy vegetation Do not mount where the transmitter or receiver could be splashed by water or mud Do not mount where the unit could be suddenly exposed to a bright light such as a floodlight or a passing automobile s headlight Do not let sunlight or any direct beam of light enter the sensing spot of the transmitter If needed mount so ...

Page 4: ...90m 1 940ft 5 200m 17 060ft 310m 1 020ft 2 600m 8 530ft Note 1 Max cable length when two or more sets are connected is the value shown in Table 1 divided by the number of sets Note 2 The power line can be wired to a distance of up to 3 300ft 1 000m with AWG22 0 33mm2 telephone wire Wiring the Transmitter Wall Mount 3 If the sensor wiring is run along the surface of the wall There are two plastic k...

Page 5: ... mounting plate See fig 4 2 Break a hole in the mounting plate s rubber grommet and pull the cable through the grommet s hole Then run the cable through the hole near the top of the sensor unit so it comes out the front Use the included mounting bracket to mount to the pole Then reattach the sensor unit to the mounting plate connect the wires and snap on the cover See fig 7 Wiring fig 8 1 Screw th...

Page 6: ...Power Alarm ch 1 Alarm ch 2 Control panel 12VDC Example connection 2 Dual Sensors Separate Channels Receiver 1 2 3 4 Transmitter 1 2 Receiver 1 2 3 4 Transmitter 1 2 Power Alarm signal Control panel 12VDC Example connection 3 In line Single Channel Receiver 1 2 3 4 Transmitter 1 2 Receiver 1 2 3 4 Transmitter 1 2 Tx Rx 1 2 1 2 3 4 Power Alarm signal Control panel 12VDC Example connection 4 Two sta...

Page 7: ...h position Important The transmitter and receiver sensor pair must be set with the same frequency Multiple Sensor Sample Application For E 964 D390Q model only Selectable 4 Channel Beam Frequency For E 964 D390Q Model Only Frequency channel CH1 CH2 CH3 CH4 Switch position Table 2 Beam Frequency Selection Chart For E 964 D390Q model only 1 2 ON 1 2 ON 1 2 ON 1 2 ON 1 Single pair multiple layer appl...

Page 8: ...ensor 5 Sensor 6 Tx Ch3 Rx Ch3 Rx Ch3 Tx Ch3 Tx Ch4 Rx Ch4 5 Two layer double stacked perimeter security application Ch1 Tx Ch3 Rx Ch2 Ch4 Tx Ch4 Ch2 Rx Ch4 Ch2 Ch3 Rx Ch1 Rx Ch3 Ch1 Tx Ch2 Ch4 Tx Ch1 Ch3 Tx Ch1 Rx Ch1 Rx Ch1 Tx Ch1 Tx Ch2 Rx Ch2 4 Perimeter security application Rx Ch2 Tx Ch3 Rx Ch4 Tx Ch2 Rx Ch1 Tx Ch1 Rx Ch3 Tx Ch4 ...

Page 9: ...t ohm meter VOM to 1 4 VDC b Insert the red probe into the terminal and the black probe into the terminal c Measure the voltage see table 4 d Adjust the horizontal angle by hand until the VOM indicates the highest voltage e Adjust the vertical angle by turning the vertical adjustment screw until the VOM indicates the highest voltage NOTE If you cannot see the opposite unit in the viewfinder put a ...

Page 10: ...to ensure the alignment and delay time settings are suitable for the site Table 5 Specifications Model E 960 D90Q E 960 D190Q E 960 D290Q E 964 D390Q Max range outdoor 90 30m 190 60m 290 90m 390 120m Max range indoor 190 60m 390 120m 590 180m 790 240m Max current Tx Rx 64mA 70mA 74mA 88mA No of beam channel N A N A N A 4 Voltage output 10 1 4 V Power 10 30 VAC VDC non polarized Detection method Si...

Page 11: ... interrupted and LED lights but no alarm trigger Alarm trigger cable may be cut or the relay contact stuck due to overloading Check the continuity of the wiring between the sensor and the alarm Alarm LED continuously lit a Lenses out of alignment b Beams are blocked c Cover is foggy or dirty a Realign the lenses b Remove any obstacles c Clean the cover Alarm trigger becomes erratic in bad weather ...

Page 12: ...lopment and improvement For that reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints All trademarks are the property of SECO LARM U S A Inc or their respective owners Copyright 2019 SECO LARM U S A Inc All rights reserved WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in nor...

Reviews: