background image

SECO-LARM Electric Door Strike with Vertical Adjustment 

 

 

 

                                                        

 

SECO-LARM U.S.A., Inc.

 

               

5

              

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Latchbolt Installation 

For installation of SD-996SS-11L1Q, SD-996SS-11L2Q, and SD-996SS-11L3Q faceplates with 
the mounting tabs shown in "Mounting the Strike Using Mounting Tabs," page 4:                         

Sample Installations: 

Dead-bolt Latch Installation 

For installation of SD-996SS-11D1Q and SD-996SS-11D2Q faceplates with the mounting tabs 
shown in "Mounting the Strike Using Mounting Tabs," page 4: 

SD-996SS-11L1Q 

Note:

 If it is necessary to cut a hole in the frame, mounting tabs 

may be required to strengthen the installation. See pg. 4. 

SD-996SS-11D1Q 

SD-996SS-11D2Q 

SD-996SS-11L3Q 

SD-996SS-11L2Q 

1

1

/

4

"  

(32mm) 

4

7

/

8

" (124mm) 

2

1

/

4

" (58mm) 

1

1

/

18

" (28mm) 

1

1

/

2

(38mm) 

1

9

/

16

" (40mm) 

1

9

/

16

" (40mm) 

1

3

/

4

(44mm) 

1

1

/

4

"  

(32mm) 

4

7

/

8

" (124mm) 

1

1

/

4

"  

(32mm) 

1

1

/

16

(27mm)

 

11

/

16

(18mm) 

3

1

/

8

(80mm)

 

4

7

/

8

" (124mm) 

1

1

/

4

"  

(32mm) 

1

1

/

8

" (29mm)

 

7

/

8

" (22mm) 

2

15

/

16

" (74mm) 

4

7

/

8

" (124mm) 

11

/

16

" (18mm) 

2

13

/

16

" (72mm)

 

1

1

/

4

"  

(32mm) 

4

7

/

8

" (124mm) 

1

5

/

16

(34mm)

Summary of Contents for SD-996C-NUVQ

Page 1: ...ic hardware mounted on the door 12 24 VDC Operation Vertical adjustable deadbolt opening sliding shim keeper and deadlatch ramp accommodates a wide range of lock types Accommodates deadbolts up to 1 F...

Page 2: ...cycles UL Tested Level IV Destructive attack Level I Line security Level I Standby power Level I Latch throw 1 25mm max with 1 8 3mm door gap Dimensions 113 16 x15 8 x35 16 47x42x84 mm Note Not all p...

Page 3: ...distance X from the side of the door frame and distance Y from the top of the door frame Use a pencil to mark the exact spot where the two lines intersect 2 Carefully peel off the short thin tab in t...

Page 4: ...Tabs Mounting Tabs Using the stick on template as a guide 1 Drill holes for mounting the strike and cut a hole for the face plate size being used It is recommended to cut the hole slightly smaller th...

Page 5: ...11D2Q faceplates with the mounting tabs shown in Mounting the Strike Using Mounting Tabs page 4 SD 996SS 11L1Q Note If it is necessary to cut a hole in the frame mounting tabs may be required to stre...

Page 6: ...y Polarity of wires is not important Crimp connectors are provided to make wiring connections easier and more reliable To install the connectors 1 Insert the wires into the connector see 12 24 VDC Wir...

Page 7: ...d adjust the deadbolt keeper up and down to align with the marked lines Adjusting Deadbolt Keeper 1 Move the door close to the strike and mark the deadlatch limit lines on the strike keeper when they...

Page 8: ...and workmanship while used in normal service for three 3 years from the date of sale to the original customer SECO LARM s obligation is limited to the repair or replacement of any defective part if th...

Reviews: