ENFORCER IR Illuminator Manual
ENFORCER IR Illuminator Manual
Dimensions:
Typical
Installation:
A. 1 EV-1323C12DW (or most other IR Cameras) (sold separately)
B. 2 VI-B1003-SBQ IR Illuminator (additional unit sold separately)
C. 1 VB-CF1Q Bracket (sold separately)
D. 1 CA-1536-1FQ (1 DC Jack to 3 DC Plugs.) (sold separately)
• Check that the correct power supply is in use.
• Check that the correct power supply is in use.
The illuminator case is hot
IR LEDs do not turn on
TROUBLE SHOOTING
Parts List
BEFORE STARTING
1. Please read this manual carefully and keep it for future reference.
2. Use the illuminator within given temperature and electricity limits.
3. Do not aim the LED light directly at the eyes when the LEDs are on.
4. Do not mount the illuminator in areas exposed to radiation, strong
magnetic fields, or strong electrical signals.*
INSTALLATION
1. Run a 12VDC power supply wire through the wall to where
the illuminator is to be mounted (if necessary).
2. Assemble the mounting bracket; then screw it into the back of
the illuminator.
3. Hold the illuminator bracket against the wall by hand where it
is to be mounted. Use a pencil to mark the location of the
three screw holes in the bracket.
4. Mount the bracket to the wall using the three included
mounting screws. If the wall is made of dry wall, brick, or
similar material, it may be necessary to use the three
included screw anchors.
5. Do not open or disassemble the illuminator. There are no user-
serviceable parts inside.
6. Do not drop the illuminator or subject it to strong vibrations.
* Note: Many video monitors produce strong electromagnetic
fields close to the CRT, especially when the monitor is turned on
or during de-Gaussing, which occurs automatically with many
monitors when the monitor is turned on.
5. Connect the 12VDC power supply.
6. Adjust the illuminator angle. Loosen and tighten the bracket’s
thumb screw to turn the illuminator and change its angle
relative to the bracket. This ensures the illuminator is pointing
in the right direction.
7. Tighten the bracket’s thumb screw so that the illuminator
does not move, but not so tight that it cracks the case or
bracket.
8. Do a final test of the illuminator.
Type
Enclosure
# of infrared LEDs
Max. LED range
Illumination angle
Power source
Power consumption
Operating temperature
Dimensions
Weight
VI-B1003-SBQ
IR Illuminator
IP67 weatherproof
24
Up to 80 ft.
35°
12VDC±10%
0.05mA (IR off), 210mA (IR on)
14°~131° F (-10°~55° C)
3
1
/
16
”(L) x 2
1
/
4
”(D) (78 x 57 mm) (without sunshield)
16 oz. (454g)
Specifications
2
1
/
4
” (57mm)
2
11
/
16
” (68mm)
1
13
/
16
” (46mm)
9
/
16
” (14.5mm)
3
1
/
16
” (78mm)
2
9
/
16
” (65mm)
A. 1 x IR Illuminator
B. 1 x Adjustable Sunshield
C. 1 x Mounting bracket
D. 36” cord
E. DC jack
F. Adjustment nut
®
Infrared
Day/Night
ENFORCER
ENFOR
CER
®
Infrared
Day/Night
C
A
B
E
Gx3
Important:
Do not cut DC jack.
Use SECO-LARM’s
EVA-F5521-3 Pigtail
Connector for easy
installation and
serviceability.
D
H
F
G. Mounting holes
H. 1 x DC pigtail connector
3 x Mounting screws
3 x Screw anchors
1 x Manual
D
B
B
A
C