background image

ENFORCER

  

 7-Day Timer

 

 

 

4

 

SECO-LARM 

U.S.A., Inc

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Set the current time in 12- or 24- hour clock format. 

 

Note: The backup battery will preserve clock time during power failure 

 

To set the time: 

Setting the Time: 
 

Entering Events: 
 

 

The 7-Day Timer can store up to 60 events. 

 

When an event is active, the event number will show on the LCD. 

 

In fixed mode, ON or OFF will show on the LCD. 

 

Fixed mode means the relay will activate with one event and deactivate with another event. 

 

In pulsed mode, ON and OFF will both show on the LCD. 

 

Pulsed mode means the relay will activate for a set period of time and then automatically  
turn off. 

NOTE:

 The timer only executes future events. For example, a Monday 8:00 AM event that is 

programmed at 10:00 AM on Monday will not execute and come into effect until the following 
Monday at 8:00 AM. 

 

Press

 SET

 

 

If the security code is enabled, enter 
the security code 

Press 

UP/DOWN 

 

Press until TIME setting mode  
is selected 

 

When selected, TIME will flash 

Press 

ENTER 

 

Enters the time setting mode 

 

TIME is solid 

 

Use the UP/DOWN keys to select 
the day of the week 

 

SU MO TU WE TH FR SA 

Press

 ENTER

 

 

Use the UP/DOWN keys to select 
the current hour 

Press

 ENTER

 

 

Use the UP/DOWN keys to select 
the current minute 

Press

 ENTER

 

 

AM or PM flashes (depending on 
current time) 

 

Use the UP/DOWN keys to select 
12- or 24-hour clock 

 

Default is 24-hour 

Press

 ENTER

 

 

Exits the time setting mode 

 

Returns to the main screen 

Operating Modes: 
 

 

The SA-027WQ has two operating modes, Automatic and Manual. 

 

In Automatic Mode the SA-027WQ follows programmed events and the ON or OFF icons are 
solid. This mode is used when programmed events are required. 

 

In Manual Mode the SA-027WQ does not follow programmed events and the ON or OFF 
icons are flashing. This mode is used to manually operate the relay. 

 

Holding the Mode button for 3 seconds switches between the operating modes. 

Summary of Contents for Enforcer SA-027WQ

Page 1: ...up to 99 days Easy to read backlit LCD Adjustable output time Programmable security code lock out 12 or 24 hr clock format 16 Schedules including daily weekly weekends etc Memory saved if power fails...

Page 2: ...rn relay OFF return to automatic mode see 3 above Hold 3 sec Reset to factory defaults SET See Programming section for details Enter settings mode Move to previous setting CODE Security code setting H...

Page 3: ...rference to prevent operation of the lock from damaging the timer A 1N4004 diode is not required for AC powered locks 4 Connect 12 24 VAC VDC to the power input terminals marked and 5 Ensure the conne...

Page 4: ...ecurity code is enabled enter the security code Press UP DOWN Press until TIME setting mode is selected When selected TIME will flash Press ENTER Enters the time setting mode TIME is solid Use the UP...

Page 5: ...program edit mode Use the UP DOWN keys to set the event day 16 different event day combinations see the chart below Press ENTER Press UP DOWN keys to select Fixed F or Pulsed P output Fixed Relay wil...

Page 6: ...l flash Press ENTER Enters the program setting mode PROG is solid Event number flashes in lower left Press UP DOWN Select event number to disable Press and hold to scan rapidly through events Press EN...

Page 7: ...egress input of the SA 027WQ This will activate the gate when the timer is not in use In this application the SA 027WQ is used to keep an entry door unlocked during normal business hours The door is...

Page 8: ...SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive r...

Reviews: