Overview:
Installation:
1.
Make sure the maximum distance between the video
source and display does not exceed the maximum range of
the video baluns.
2.
Run the UTP cable from the video source to where it will
be connected to the display destination.
3.
Connect UTP cable to the two video baluns.
For standard baluns slide the cover off of the video balun
and connect two wires to the terminal block located inside
the balun. See figure 1.
4.
For the correct length of bare wire, see figure 3 on page 3.
For snap-in baluns connect the RJ 45 plug according to
T568B wiring standards. Plug the video baluns into the RCA
connectors on the source and destination.
NOTE: The baluns are polarity-sensitive. Observe
correct polarity.
Wire Exit Holes
NOTE: Composite baluns are connected in pairs. One connects to the video source RCA
output connector, and the other connects to the video destination RCA input connector.
Center-pin
(positive)
Shielding
(ground)
Figure 1 – Video balun with
cover removed
Shielding
(ground)
Pin 7 (-)
Pin 8 (+)
Modular Balun:
Snap-in Balun:
Please use T568B wiring standard for RJ45 connectors.
Figure 2 – Connecting
Cat5e/6 Cable
ENFORCER Composite Video Balun
SECO-LARM U.S.A., Inc 3
Sample Application #1: Standard Composite Video Baluns
Composite Video
Source, VCR,
Gaming System
Display
Up to 2,230’ (680m)
5.
Test the connection by powering up the video
source and destination.
6.
If using standard baluns, replace the covers on the
video baluns and make sure the wires exit through
the two small holes on the back of the units.
NOTE: Bare wires must not be exposed
outside the video baluns.
Sample Application #2: Modular Snap-in Composite Video Baluns
MVE-PB010Q
MVE-PB010Q
(wall plates not included)
Up to 2,230’ (680m)
MVE-PB020Q
MVE-PB020Q
Figure 3 – Video balun with
cover removed
Cat5e/6
ENFORCER
Composite Video Balun
SECO-LARM
Ideal Copper Length
Expose ¼” copper wire of the UTP for
connection to the balun. Use the “ideal
copper length” guide on the balun.
SECO-LARM has a complete line of audio/video products.
Please visit www.seco-larm.com for more information.
Display
ENFORCER
ENFORCER
Composite Video
Source, VCR,
Gaming System
Component Video
Source
Display
MVE-PB010Q
MVE-PB010Q
Sample Application #3: Component Video
ENFORCER
ENFORCER
ENFORCER
ENFORCER
ENFORCER
ENFORCER
Y
Y
Pb
Pb
Pr
Pr
Up to 2,230’ (680m)