7.

 Put a rubber washer between the two metal washers 

and place them over the armature screw between 
the armature plate and the door. This allows the 
plate to pivot around the screw to compensate for 
door misalignment. 

 

9

.

 Screw the two short self-tapping screws through the mounting plate’s slotted holes, but do not over-tighten them. 

Keeping them loose will allow for adjustment of the plate left or right so that the mounting plate and the armature 
plate form a 90-degree angle. See the diagram below. 

8.

 Tighten the armature screw enough so that the 

armature plate can withstand a break-in attempt, but 
loose enough so that the armature plate can pivot 
slightly. Make sure the anti-spin guide pins are in the 
two guide pin holes. 

 

 

Mounting Plate 

Armature Plate 

90° 

 

The rubber washer will be 

sandwiched between the 

two metal washers. 

Armature 

screw 

Guide pins 

 

6.

  Depending on the type of door being protected, drill holes according to the diagrams below: 

 

 

 

Hollow Metal Door 

Solid Core Door 

Reinforced Door 

1/4" (6.8mm) for M8x1.25 thread 

Drill a 5/16" (8mm) dia. hole through the 
armature-plate side of the door for the 
armature screw. Then drill a 1/2" 
(12.7mm) dia. hole for sexnut screw on 
the opposite side of the door. 

Drill an 5/16" (8mm) dia. hole on the 
door for the armature screw and drill a 
1/2" (12.7mm) dia. and 1" (25mm) deep 
hole for the sexnut screw. 

Drill a 1/4" (6.8mm) 
dia. and 1" (25mm) 
deep hole, tap for 
M8x1.25 thread. 

  Tip: 

Use a thread-locking compound 

 

on the armature screw to ensure 

 

a long-lasting installation.

 

Metal 

washers 

1/2" (12.7mm) 

5/16" (8mm) 

1/2" (12 .7mm) 

5/16" (8mm) 

E-941Sx-600 mounting plate 

 

E-941Sx-1200 mounting plate 

Summary of Contents for E-941S 600 Series

Page 1: ...face is needed to securely mount screws for magnet may need filler plates or angle bracket to mount magnet correctly WARNING Warnings indicate potentially hazardous conditions which if not avoided or...

Page 2: ...ting plate 913 16 x1 x3 16 250x25x5 mm 101 2 x19 16 x1 4 267x40x5 5 mm Armature plate 71 4 x5 8 x15 8 185x16x42 mm 71 4 x5 8 x23 8 185x16x61 mm Operating humidity 0 85 non condensing Operating tempera...

Page 3: ...self tapping screws Armature plate Guide pins Rubber washer Steel washers Hex head mounting screws NOTE When mounting the electromagnet it may be necessary to use a Z bracket 1 or 2 L brackets dependi...

Page 4: ...lock as this may cause a delay when releasing the door as well as cause residual magnetism 6 The best location to install the electromagnetic lock is on the inside of the door that is being secured w...

Page 5: ...nti spin guide pins are in the two guide pin holes Mounting Plate Armature Plate 90 The rubber washer will be sandwiched between the two metal washers Armature screw Guide pins 6 Depending on the type...