I  Introduction 

 

After removing the unit from its packaging and ensuring that it has suffered no damage in shipment, it 
is important to read this manual and follow its instructions to ensure proper connection and mounting.  
 
711HS Series models are fully isolated dc-dc converters capable of delivering up to 720 Watts in 
extreme ambient temperatures and adverse operating conditions. See specification sheets at the end 
of this manual for the ratings of a particular model.   

 

II  Installation 

 

2.1 Mounting 

 
The converters are designed to be mounted to flat metal surfaces offering optimum heat transfer from 
the converter base in environments where air flow may be restricted. For best results, thermal 
transfer compound is a recommended interface between the converter and mounting surface. The [4] 
mounting slots in the flanges will accommodate mounting hardware up to ¼ inch diameter. (See 
figure #2 for mounting centers)  
 

2.2 Connections 

The Input/Output connectors on the converter is shown in Figure 1/1A  with designated pin functions. 

A - Positive Sense

B - Negative 

C - Negative Sense

D - Positive 

E - Housing Ground 

A - Input Negative

B - NC 

C - Remote Enable

D - Input Positive 

F - NC 

A

B

C

D

E

F

Input 

A

B

C

D

Output

ON

OFF

 

ON-OFF switch feature on BK Model 

                               

                                    

 

 
 

Figure 1 

 

 

 

 

 

        Figure 1A 

 
 
 
 
An option for users who wish to purchase a manufactured cable assembly is P/N 68-0711-8 which is 
of 8 feet length and is a standard SEC part. 

 

 

Page 1 

Input side mating connector 

Canon P/N 3106E20-8SB 

 
 

 

Output side mating connector 

Canon P/N 3106E20-24PB 

PIN            Max. Wire Gauge 

A, D                 #8 
C, E 

 

#12 

PIN            Max. Wire Gauge 

B, D                 #8 
A, C 

 

#12 

Summary of Contents for 711HS Series

Page 1: ...SEC SEC America Corp www secamerica com USER MANUAL 711HS Series DC DC Converters Applies to Models 711HS 711HSBK Aug 15 2018...

Page 2: ...F CONTENTS page I Introduction 1 II Installation 1 2 1 Mounting 1 2 2 Connections 1 2 3 Mechanical Drawing 2 III Remote Sense Regulation 2 IV User Adjustments 3 IV Warranty 4 V Electrical Specificatio...

Page 3: ...ts thermal transfer compound is a recommended interface between the converter and mounting surface The 4 mounting slots in the flanges will accommodate mounting hardware up to inch diameter See figure...

Page 4: ...ngth the voltage at the end of the cable may be noticeably lower than at the terminals The converter can compensate up to 0 75V of voltage drop through remote sense terminals To ensure accurate regula...

Page 5: ...nting surface upwards until the view in Figure 5 can be attained With P N ATC 30 Replace Fuses ATC 30 1 2 3 jumper 2 3 Unit ON jumper 1 2 ON by Remote Pin Output Voltage Adjustment jumper P1 CON1 F1 2...

Page 6: ...hould take every precaution to ensure that a reversed polarity input is avoided Any polarity reversals may result in permanent damage 3 Restore the front plate to its orginal position by replacing the...

Page 7: ...be thus defective LIMITED WARRANTY The above limited warranties take the place of all other warranties expressed or implied and correction of such defects by replacement or repair shall constitute a...

Page 8: ...Page 6...

Page 9: ...Page 7...

Page 10: ...SEC SEC America Corp P O Box 2266 South Burlington 78 Ethan Allen Drive VT 05403 www secamerica com Tel 802 865 8388 Fax 802 865 8389 cage code 07KU1...

Reviews: