Quantity
1
1
2
1
1
4/2
1. Packing List
Name
Standalone Proximity Reader
Infrared remote control
Manager card
Short Pin
User manual
Self Tapping Screws
Specification
W2
One for add, one for delete
Used for factory default setting
W2
3.5*27mm
The W2 is fully waterproof standalone Proximity access Reader, which uses advanced
microprocessor, equipped with large capacity Flash memory, supports up to 10,000
cards. It is so easy to add or delete card users by using the master card, besides, with
Infrared remote control programmer, the user can set the features by themselves,
including Alarm, Self-protection, interlock and Anti-submarine back Function. In
additional, with infrared remote control programmer, you can add or delete cards
directly by inputting card number.
The W2 not only has the features of low power consumption,
automatic selection of lock
,anti vandal alarm and exit button, but also has the protective functions against input over
voltage and outputs short-circuit. These features make the W2 safe , reliable and easy in
operation. It is an ideal choice for door access.
2. Description
Standalone Card Reader
User capacity: 10,000
Card interface: 125KHZ EM card
Remote control for programming
With Manager cards for fast add
and delete users
Wiegand26 input/output
3. Features
Can be used as salve reader
2 pcsW2 can be interconnected/ interlocked
Can be used as controller by connecting
slave reader
Anti-submarine back Function
Alarm signal output, Door open detection
Full of 10,000 users, recognizing speed <15ms.
4. Specifications
-20
60
20%
98%
Max20A
Max20A
Two
103 x 48 x 23mm
Temperature
Humidity
Lock output load
Alarm output load
Manager card
Dimensions
Supply Voltage
Sleeping Current
Card type
Card Reading Distance
Wiegand interface
User capacity
DC12V
10%
<15mA
125KHZ EM card
5
10cm
Wiegand 26
10,000
Drill holes on the wall or prepare the cassette.
Wire through the hole, and blanket the unused cable in case of short circuit.
Fix the back cover firmly on the cassette or the wall.
Attach the reader to the back cover.
5. Installation
Shielded
cables
C
D
6
1
m
m
9
5
.5
m
m
40mm
A
B
6. Wiring
No
1
2
3
4
5
6
7
8
9
10
Color
Yellow
Blue
Brown
Purple
Grey
Red
Black
White
Green
Orange
Function
D0
D1
ALARM+
OPEN
D_IN
12V
GND
VSS
L-
L+/Alarm+
Description
Wiegand output, input signal wire D0
Wiegand output, input signal wire D1
connecting to the negative pole of the alarm equipment
To connect to one part of Exit Button
Door Contact input
(+) 12Vdc Positive Regulated Power Input
(-) Negative Regulated Power Input
the negative pole of the controller, connect to the other
part of Exit button and door contact
Connect to the negative pole of the Lock
Connect to the positive pole of the lock and alarm equipment
Connection Diagram
DC12V/3A
+
-
-
+
Lock
-
+
Exit button
Alarm
door detecting switch
Common Power Supply
W 2
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
J1
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
DC12V/3A
+ -
COM
NC
NO
PUSH
Exit button
Alarm
door detecting switch
F
a
il-
s
e
c
u
re
lo
c
k
F
a
il
-s
a
fe
lo
c
k
Special Power Supply
D0
ALARM-
J1
D1
Green
White
Grey
OPEN
D_IN
+12V
GND
VSS
L+
ALARM+
L-
Yellow
Brown
Red
Black
Blue
Purple
Orange
To add a card user(Method 2)
To delete a card user
2 Read Card # or
2 Card number (8 digit) #
To delete ALL users.
(
Note:
This option will delete all users but
Manager Cards. Be careful with use)
2 0000 #
1 Input Card number (8 digit) #
The card number is the last 8 digits of the
number printing on the card.
Door open detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic
contact or built-in magnetic contact of the lock, if the door is opened normally, but
not closed after 1 minute, the inside buzzer will beep automatically to remind
people to close the door and continue for 1 minute before switching off
automatically.
Door Forced Open warning. When used with an optional magnetic contact or built in
magnetic contact of the lock, if the door is forced open, or if the door is opened after
120 seconds of the electro-mechanical lock not closed properly, the inside buzzer
and alarm output will both operate.
To disable door open detection.
(Factory default)
Security Mode Setting
Reader Lockout & Alarm Output options.
If there are 10 invalid cards within 1 0 mi nut es,
the Reader will lockout for 10 minutes or the alarm will operate for 10 minutes,
depending on the option selected below.
Normal status (No lockout or alarm)
7 0 # (Factory default setting)
Anti-submarine Disabled
Anti-submarine Master Mode
Antisubmarine Auxiliary Mode
(
Note:
the detailed wiring diagram and illustration, please refer to the
Advanced application
) .
(Factory default)
3 0 #
3 1 #
3 2 #
To enable door open detection
6 0 #
6 1 #
Reader Lockout
7 1 #
Alarm Output
7 2 #
Door Interlock.
Door interlock disabled
Door interlock enabled
8 0 #
8 1 #
Alarm output time
To set the alarm output time (0-3
minutes) Factory default is 1 minute
9 0~3 #
I/O
ALARM-
R8
R20
Q6
Lock Interface Principle:
By programme setting, I/O
switch between low level and
high level.
4-low level
5-high level
I/O
L-
L+
+12V
R7
R19
Q2
D6
Alarm Interface Principle:
when alarm, the I/O outputs high level.
7. Interface Circuits
Figure 1
8. To Reset to Factory Default and Manager Card setting
Power off, use the supplied Contact Pin to short out the 2P socket on the mainboard,
then power on, if successful, the beeper will beep twice, the LED shines in orange,
remove the Short Pin, then read any two EM cards, after that the LED turns in red,
means reset to factory default setting successfully. of the two EM cards read, the first
one is Manager add card, the second one is Manager delete card.
Remarks: Reset to factory default setting, the users' information enrolled is still retained.
When reset to Factory default setting, the two Manager cards must be re-enrolled.
9. Sound and Light indication
Operation status
Reset to factory default setting
Sleeping mode
Operation successful
Enter into programming mode
Enter into setting
Exist from programming mode
Operation failed
Open the door
Alarm
LED
Orange
Red shines slow
Red shines
Orange shines
Red shines slow
Green shines
Red shines fast
Buzzer
Two short ring
Short ring
Short ring
Short ring
Short ring
Three short ring
Short ring
Alarm
10. W2 Detailed Programming Guide
10.1 User settings
There are 2 ways to add and delete users:
A - By manager card; B - By remote control
A - By Manager card(The most convenient way)
To Delete User by Manager Card
B- By Remote control
Manager add card Read user card Manager
add card Cards can be added continuously.
Manager delete card Read user card Manager
Delete ca rd Cards can be deleted continuously.
To Add user by Manager Card
To add a card user (Method 1)
1 Read Card #
Card can be added continuously without
exiting programming mode.
To Enter the programming mode
Remarks:
All the steps below must be done after entering into programming mode
To change the master code
0 New Password # Repeat New Password #
The master code must be 6 8 digit number.
* Manager Password #
888888 is the default factory master code
10.2 Door setting
Fail secure (Unlocked when power on)
Fail safe (unlocked when power is off)
4 0
99 #
0-99 is to set the door relay time 0-99 seconds.
5 0 99 #
0-99 is to set the door relay time 0-99 seconds.
Lock Power Setting
Anti
-
submarine Settings
This is the factory default, 3 seconds:
To Unlock the door
To remove the alarm
To remove the door forced open warning
Read valid card or Master Code #
To remove the door open too long
warning
Close the door or Read valid card
or Master Code #
Read user card
Note:
that Manager Card can't be used to unlock the door.
To Unlock the door
Please ensure that all the above contents are correct. If any are missing, please notify the supplier of the W2.
Do not power on until all wiring has been completed
Note:
The above diagrams show the output interface circuits. Unlike most lock and
alarm outputs which use a relay that can be shocked or magnetized, the W2 uses MOS
outputs for both the Lock Output on the left and the Alarm Output on the right.
.2.
.3.
.4.
.5.
.1.
.6.