Sebury BC2019 Instruction Manual Download Page 8

5

0#

Set to normal mode

0

(1-3)#

Set the alarm time to 1-3 minutes

6

0#

To disable door open detection

0

1#

To enable door open detection

7

0#

To set normal mode

0

1#

To set lock mode

2#

TO set alarm output

Enter Master Operation Mode: *(6 digits administrator code)#

Menu

Parameters or operation steps

Function

Default

0

( new administrator password ) #,( new

administrator password again)#

Modify administrator password

888888

1

* read card,…,*

Quickly add user card

(ID No.)#,read card,…,*

Add user card with ID No.

(ID No.)#(user pin)#,…,*

Add user pin with ID No.

2

Read card,…,*

Quick delete card

(ID No.)#,…,*

Delete card or pin with ID No.

0000#,*

Delete all the users

3

0#

Entry by card

2

1#

Entry by card with pin together

2#

Entry by card or pin

3#

Entry by only pin

4

0#

to set door relay time 50ms

To set door relay time 50ms

0

(1-98)#

To set door relay time 1-98s

99#

To set the switch mode

Fault
phenomenon

Fault Cause

Reason & Solution

Unusual
Indicator light

Power voltage too low or too much interference

Change to qualified power supply,
cable or restoring power

No response

Continuously swipe in lock mode or input the pin
code more than 10 times

Restoring power or wait for 10 min.

Abnormal
unlocking

Wrong electric lock mode

Set the different modes follow the
way of different electric locks

Wrong wiring

Follow the right way of wiring

Can’t enter

administrator

mode

Make sure the red indicator light normally on

before press *

Follow the right operation way

Forget the master password

Factory reset

Can’t enter
by card

Set the mode of entry by pin

Set the right open mode

Too much interference of power or power voltage
too low

Change to good power supply or
cable

Can’t enter
by pin

1. Need to set the pin first, master setting or users
change the 1234 to new 6 digits pin by themselves

Set or change the user pin
password

3.

Input the wrong pin password

Input the right pin password

Digits key
invalid

To set the entry by card or card & pin

Set the right entry mode

5. Simple Troubleshooting

Summary of Contents for BC2019

Page 1: ...and the user can modify password by himself Opening door modes card card password card or password password Opening time 50mS 1 98 seconds for normal mode 99 seconds for switch mode It can connect wi...

Page 2: ...tamper screw on the bottom of the product with the special anti tamper screwdriver remove the back case of the product then according to the opening position of the back case use the impact drill to o...

Page 3: ...screws and fix them As shown below The correspondence between the color of wire and their function Door Strike Relay NC Door Strike Relay NO Door Strike Relay Com Alarm Switched negative when active T...

Page 4: ...orange Under administrator mode it will automatically exit to standby state if there is no operation within 30 seconds Under non administrator mode it will automatically exit to standby state if there...

Page 5: ...rd For example consecutively set 3 passwords with ID numbers 4 5 and 6 14 444444 5 555555 6 666666 3 4 Deleting users There are three ways to delete a user where the ID number ranges from 0 to 999 eve...