background image

Page 6

Starting The Machine -

Figures 1 & 2

A.

Before turning on your vacuum cleaner, make sure that the

vacuum handle is in its upright locked position and that you have a firm
hold on the handle grip to keep the machine from moving forward.

1.

Turn the quick release cable hook (14) to the up position
by moving it to the left or right (figure 1).

2.

Release the power cord plug from the power cord
and lift the cord off of the upper cord hook (27 - figure 2).

3.

With the switch (2) in the “O” (OFF) position (figure 2), plug the
polarized power cord into a 120 volt outlet located
near the floor.

Switch Position

O = OFF
I

= ON

Operating Positions -

Figure 3

B.

When the machine is switched on with the handle in the upright locked

position (see

A

above), the power head and brush automatically rise from

the carpet. To release the machine from the upright locked position, press
down on the foot pedal (19) and lower the handle into the normal operat-
ing position. The brush will automatically lower.

The handle can be lowered to an intermediate stop position in order to lift
up the brush head for maneuvering over rugs, etc. To lower the handle to
a horizontal position useful for vacuuming under beds, the foot pedal must
be pressed a second time. The intermediate stop position can be closed
off by the orange-colored slider (28) on the back of the swivel neck (20),
so that the handle will go from vertical to horizontal in one movement.

WARNING!

The quality, condition, coating, texture, age and manufacturing technique of all floor surfaces vary.

Therefore, upright vacuums with rotating brushes, including your SEBO, may damage some floor coverings or surfaces.
Some types of high-gloss hardwood floors, cushion vinyl, berber carpets, long shag, and delicate or hand-woven carpets are
particularly vulnerable to damage by rotating brushes. When possible, consult the materials supplied by your floor’s manu-
facturer for information on proper upkeep and cleaning.

To ensure that your new SEBO vacuum cleaner is compati-

ble with your floor, please test the vacuum cleaner on each type of flooring surface in a small inconspicuous
area to determine if any damage occurs. If damage occurs, stop using the vacuum cleaner immediately!

Care must be taken to ensure that the bottom of the machine does not contact the floor.

If this happens, damage

to the floor could occur.

If damage occurs, stop using the vacuum cleaner immediately!

14

2

27

!

28

Operating Instructions

19

Figure 1

Figure 2

Figure 3

Summary of Contents for essential G1

Page 1: ...SEBO essential G Series For Household Use Only Copyright SEBO America LLC All rights reserved ENGLISH ...

Page 2: ...ning 4 Stationary Use Warning 4 Bag Full or Clog Warning Auto Shut Off 4 Identification of Parts 5 Assembly 5 Optional Attachments 5 Standard Attachments 5 Operating Instructions 6 Starting the Machine 6 Operating Positions 6 Using the Attachment Tube Hose Attachments 7 The Display Panel 7 The Adjustment Wheel 7 Maintenance 8 Changing the Dust Bag 8 Changing the Micro Hygiene Filter 8 Changing the...

Page 3: ...he other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way Connect only to the outlet type specified on the serial number plate underneath the machine SAVE THESE INSTRUCTIONS WARNING To reduce the risk of fire elec...

Page 4: ... light is illuminated continuously while the head is in position 1 after a 10 second delay it is signalling the user that the brush roller is too worn and therefore should be replaced The light will remain illuminated until the worn brush roller is replaced but the machine will continue to operate in the meantime 4 Stationary Use Warning When the machine has its handle in the upright locked positi...

Page 5: ...22 slide the handle in making sure that the handle is all the way in and cannot go any further Push the catch 22 down to lock handle in place If the han dle is not pushed fully down the vacuum will not work Push the black end of the attachment hose 12 into the connecting tube 24 so that it clicks into place Insert the attachment tube 15 into the swivel neck and push the han dle 11 over the project...

Page 6: ...orizontal position useful for vacuuming under beds the foot pedal must be pressed a second time The intermediate stop position can be closed off by the orange colored slider 28 on the back of the swivel neck 20 so that the handle will go from vertical to horizontal in one movement WARNING The quality condition coating texture age and manufacturing technique of all floor surfaces vary Therefore upr...

Page 7: ...ide of the bag housing 6 and the power head is locked in a perpen dicular position to the floor To vacuum walls under beds or higher reach areas etc the SEBO essential G can be fitted with an additional straight tube 45 and the wall and floor brush 41 The machine will then perform as a canister vacuum as shown in figure 3 The pile adjustment wheel 18 has 4 brush height settings Setting 1 is the lo...

Page 8: ...AM Exhaust Filter Part 2846 Brush Roller G1 Part 5010AM Brush Roller G2 Part 2838AM Changing the Exhaust Filter Figure 11 After 20 bags have been used change the exhaust filter 33 Remove the dust bag housing 6 from the power head by pressing the housing release button 8 To remove the exhaust filter push the catch 34 and remove the filter cover 35 and exhaust filter Insert the new filter replace th...

Page 9: ...of the machine s original assembly see assembly page 5 Figure 17 Figure 14 Figure 13 Clogs in the Attachment Tube Active Wand Figure 15 Remove attachment hose 12 from the attachment tube 15 by pressing the hose release button 27 Then grip attachment tube handle 11 and remove tube from the machine A straight wire can be inserted into the tube to push out the clog Always unplug vacuum from outlet be...

Page 10: ... not inserted properly 3 Microfilter not properly inserted 1 Attachment tube not properly inserted SOLUTION 1 Release handle catch push handle down close handle catch 2 Use another outlet 3 Replace cable 4 Housing release button 8 should be snapped outward to its locked position 1 Replace bag See 5 on page 4 2 See Clog Removal on page 9 Also see 5 on page 4 3 Replace microfilter 1 Replace brush Se...

Page 11: ...al cover complete incl pos 43 44 Cable clamp Filter safety catch Return spring Clamp Handle lock plate Lock catch Lock pin 4 x 33 5 Carrying handle Stop spring Cable hook Retaining ring Dust bag housing Attachment clip Spring for locking rod Internal cable Cable clamp Seal Seal Seal Dust bag housing bumper base Dust bag housing locking catch teal Locking rod Dust bag housing light gray teal Uphols...

Page 12: ...edal orange Axle spring Wheel complete Axle clamp Brush roller Bearing block r h teal light gray Rubbing plate Access door incl pos 127 128 Access door axle Access door spring Pile adjustment axle Pile adjustment wheel Axle clamp Screw AM4 x 16 Cover Thrust member Pile adjustment knob Thrust member Clamp Spring Chassis complete Front bottom plate complete Rear bottom plate complete incl pos 142 Sc...

Page 13: ...el neck support l h Swivel neck bearing l h PCB Power supply Internal Cable Brush roller release teal Spring Axle assembly Axle Foot pedal orange Axle spring Wheel complete Axle clamp Brush roller Bearing block r h teal light gray Rubbing plate Access door incl pos 127 128 Access door axle Access door spring Pile adjustment axle Pile adjustment wheel Axle clamp Screw AM4 x 16 Cover Thrust member P...

Page 14: ...t of proof of purchase and determines the validity of warranty To be certain that your warranty claim can be processed as quickly and efficiently as possible please retain your original purchase receipt and mail in the warranty card provided with your new SEBO vacuum cleaner You may also reg ister on our website at www sebo us 10 This warranty gives you specific legal rights You may also have othe...