INSTALLATION 

NOTE:  DO NOT INSTALL THE WATER HEATER ON ITS SIDE OR UPSIDE DOWN. 
 

1.

 

Locate water heater at engine level as close to engine as possible. 

 

2.

 

Secure mounting brackets to structure with eight #12 minimum screws or ¼-20 minimum 
cap screws and nuts. 

 

3.

 

Connect cold water supply and hot water outlet to heater as marked, ½” NPT fittings 

 

4.

 

Connect heat exchanger system described in figure above.  Make sure coolant system is 
completely purged of air and full of coolant before operating. 

 

5.

 

The pressure temperature relief valve is factory installed.  The pressure relief valve shall 
limit the pressure to 127.5 PSI (879.3 KPA) minimum, 150 PSI (1034.2 KPA) maximum. 

 

The valve must be oriented, provided with tubing, or otherwise installed so that the 
discharge can exit no more that 6 inches above, or at any distance below the structural 
floor and cannot contact any live electrical part. 
 
Install replacement temperature and pressure protective equipment required by local 
codes, but not less than a combination temperature and pressure relief valve certified as 
meeting the requirements for relief valves and automatic gas shutoff devices for hot water 
supply systems, ANSI Z21.22 by a nationally recognized testing laboratory that 
maintains periodic inspection of production of listed equipment or materials. 
 

6.

 

Connect the electrical supply by a qualified electrician.  The electrical supply shall be 
permanent wiring, armored cable or conduit, per national electrical code NFPA 70, with a 
minimum capacity of 1500 watts.  On 120 volt circuits, use a UL approved 15 amp circuit 
breaker.  On 240 volt circuits, use a 10 amp approved circuit breaker per leg. 

 

7.

 

GROUNDING INSTRUCTIONS:  The supply ground shall be connected to the green 
wire located in the water heater wiring compartment.  Do not place the switch in the 
ground circuit. 

 

 

Summary of Contents for S1800

Page 1: ...Seaward Products WATER HEATERS OWNER S MANUAL FOR ELECTRIC HEAT EXCHANGER WATER HEATERS 20 GALLON VERTICAL MODELS S1800 S1850 S1900 S1950 ...

Page 2: ...eater may result in excessively hot water This water heater tank and heat exchanger is made of aluminum Some engine manufacturers recommend that the cooling system be flushed periodically Caustic chemicals are commonly used DO NOT flush caustic chemicals such as Nalcool through your system with the heat exchanger hooked up or damage WILL occur to the heater If flushing is required by your engine m...

Page 3: ...water system 4 The temperature pressure valve may weep during initial installation operation This is normal The valve will seat itself with use NOTE Do not operate water heater without element be submerged in water MAINTENANCE 1 Check heat exchanger lines for leaks at regular intervals A leak in the system will cause coolant loss and may damage engine 2 Flush tank periodically to help prevent buil...

Page 4: ... below the structural floor and cannot contact any live electrical part Install replacement temperature and pressure protective equipment required by local codes but not less than a combination temperature and pressure relief valve certified as meeting the requirements for relief valves and automatic gas shutoff devices for hot water supply systems ANSI Z21 22 by a nationally recognized testing la...

Page 5: ...the limit switch activates proceed as follows Turn power off at main power panel or remote switch Remove wiring access cover Depress red button on high temperature limit switch Replace cover and turn power on If temperature limit switch reactivates contact a Seaward Products authorized service center ...

Reviews: