Operating Instructions
30
PAC3760 DL
6 Specifi cation
Earth Continuity
Display Range
0.01ohms to 19.99ohms
Measuring Range
0.05ohms to 19.99ohms
Accuracy
± (5% + 2 digits)
Test current
200mA minimum
Test voltage
6V nominal
Insulation resistance
Display Range
0.01Mohms to 19.99Mohms
Measuring Range
0.10Mohms to 19.99Mohms
Accuracy
± (5% + 2 digits)
Test voltage
500V +20% -10% at 1M
Ω
Test current
<2mA into 2k
Class I Leakage Current
Display Range
0.15mA to 9.99mA
Measuring Range
0.25mA to 9.99mA
Accuracy
± (5% + 2 digits)
Test voltage
mains voltage, 50Hz AC
Class II Leakage Current
Display Range
0.10mA to 5.00mA
Measuring Range
0.10mA to 5.00mA
Accuracy
± (5% + 2 digits)
Test voltage
mains voltage, 50Hz AC
3-Phase Leakage Current
Display Range
0.10mA to 9.99mA
Measuring Range
0.25mA to 9.99mA
Accuracy
± (5% + 2 digits)
Test voltage
mains voltage, 50Hz AC
Cord Test
Earth continuity, insulation resistance as above.
Check for Live and Neutral open circuit, short circuit
or reversed polarity.
RCD Test
Display Range
0ms to 500ms
Test Current
±5%
Current Accuracy
±2ms