Seav RES 2175 Wiring Instructions Download Page 2

that it has been coded successfully. This process can then be repeated for additional transmitters

WIRING DIRECTIONS – all Terminals are to be read left to right

ALWAYS ENSURE THE 24 Volt TERMINAL IS IDENTIFIED AND CONNECTED FIRST

– ENSURE ALL POWER IS ISOLATED AND TURNED OFF 

Electric operator

Operator Terminals

Seav Receiver Terminals

SLAVE DOR

T.1

24 Volt +

T.1

24 Volt +

T.2

0 Volt (Common)

T.2

0 Volt (Common)

T.3

Start Contact (n.o)

T.3

Start Contact

T.2

0 Volt (Common)

T.4

0 Volt (Common)

GB1 Liftboy

T.1

24 Volt +

T.1

24 Volt +

T.2

0 Volt (Common)

T.2

0 Volt (Common)

T.3

Start Contact (n.o)

T.3

Start Contact

T.2

0 Volt (Common)

T.4

0 Volt (Common)

CHAMBERLAIN 

T.1

Start Contact (n.o)

T.3

Start Contact

LIFTMASTER

T.2

0 Volt (Common)

T.2

0 Volt (Common)

(and old type Wickes unit)

T.3

24 Volt +

T.1

24 Volt +

T.2

0 Volt (Common)

T.4

0 Volt (Common)

CHALLENGER

T.1 (COM)

0 Volt (Common)

T.2

0 Volt (Common)

(Terminals - left to right)

T.2 (PB)

Start Contact (n.o)

T.3

Start Contact

T.3 (OBS)

24 Volt +

T.1

24 Volt +

T.1 (COM)

0 Volt (Common)

T.4

0 Volt (Common)

BERNAL RALLYE

T.1

0 Volt (Common)

T.2

0 Volt (Common)

T.3

24 Volt +

T.1

24 Volt +

T.14

Start Contact (n.o)

T.3

Start Contact

T.15

0 Volt (Common)

T.4

0 Volt (Common)

HENDERSON 880

T.6

Start Contact (n.o)

T.3

Start Contact

with 6 Terminals

T.2

0 Volt (Common)

T.2

0 Volt (Common)

T.5

24 Volt +

T.1

24 Volt +

T.2

0 Volt (Common)

T.4

0 Volt (Common)

HENDERSON

T.2

Start Contact (n.o)

T.3

Start Contact

With 5 Terminals

T.1

0 Volt (Common)

T.2

0 Volt (Common)

T.3

24 Volt +

T.1

24 Volt +

T.1

0 Volt (Common)

T.4

0 Volt (Common)

MARANTEC

T.1

0 Volt (Common)

T.2

0 Volt (Common)

With 3 Terminals

T.2

Start Contact

T.3

Start Contact

Comfort 130 - 252

T.3

24 Volt +

T.1

24 Volt +

T.1

0 Volt (Common)

T.4

0 Volt (Common)

MARANTEC

T.1

24 Volt +

T.1

24 Volt +

With 5 Terminals on

T.2

0 Volt (Common)

T.2

0 Volt (Common)

Green block

T.3

Start Contact

T.3

Start Contact

Ignore T.4 & T.5

T.2

0 Volt (Common)

T.4

0 Volt (Common)

HORMANN

T.1

0 Volt (Common)

T.2

0 Volt (Common)

Registered in England No 233 5784                         V A T No 527 3897 10