The   control   unit   is   supplied   by   the   manufacturer   with   the 
possibility of selecting only the functions of the main menu.
To   enable   the   functions   of   the   extended   menu   follow   this 
procedure: press the SET key continuously for 5 seconds, the 
T. MOT. and T. PAUSA LED’s flash alternatively and the user 
has 30 seconds time to select the functions of the extended 
menu with the SEL and SET keys, after 30 seconds the control 
unit returns to the main menu.

---------------------- EXTENDED MENU -----------------

LED status

LED off

       

LED on

A) FUN. IN/OUT

remote PGM = OFF  

remote PGM = ON

B) CODE

  

Photoelectric cells test = ON Photoelectric   cells   test   = 

OFF
C) CODE PED.

   

Pressure Maint. = OFF

             

Pressure 

Maint. = ON
D) INB.CMD.AP

  

Electronic brake = OFF

             

Electronic 

brake = ON
E) LAMP/CORT/CO

 

Closure strike = OFF

       

Colpo chiusura = ON

F) THE ARIES EFFECT

        

Not used

G) T. MOT.

 Flashing beacon ON/OFF

H) T. PAUSA.

 

Flashing beacon ON/OFF

A)  FUNCTION IN/OUT 
(Remote programming of radio control) :

The control unit allows for programming the transmission code 
from remote, without using the SEL key.
To programme the transmission code from remote follow this 
procedure: send the radio control code continuously for more 
than 10 seconds, the control unit enters the programming mode 
as illustrated above for the CODE LED in the main menu.
The   control   unit   is   supplied   by   the   manufacturer   with   the 
remote programming of the transmission code not enabled; to 
enable   the   function   follow   this   procedure:   check   that   the 
extended menu is enabled (T. MOT. and T. PAUSA LED’s start 
flashing   alternatively),   with   the   SEL   key   go   to   FUNCTION 
IN/OUT   LED   when   flashing   and   press   the   SET   key:   the 
FUNCTION IN/OUT turns on and programming is completed. 
Repeat the operation to restore the previous configuration.

B)  CODE (Photoelectric Cells Test):

The   control   unit   is   supplied   by   the   manufacturer   with   the 
photoelectric   cells   test   is   enabled   (in   compliance   with   EN 
12453); to disable the function follow this procedure: check that 
the extended menu is enabled (T. MOT. and T. PAUSA LED’s 
start flashing alternatively), with the “SEL” key go to CODE LED 
when flashing and press the “SET” key: the CODE turns on and 
programming is completed. In this way the photoelectric cells 
test   is   not   performed;   also   if   they   are   not   connected   (if   not 
used, DS2 input must be bridged) the control unit is enabled for 
operation.   Repeat   the   operation   to   restore   the   previous 
configuration.

C) CODE PED: (Maintenance of Hydraulic Motor Pressure):

The   control   unit   is   supplied   by   the   manufacturer   with   the 
maintenance   of   hydraulic   motor   pressure   not   enabled.   To 
enable   the   function   follow   this   procedure:   check   that   the 
extended menu is enabled (T. MOT. and T. PAUSA LED’s start 
flashing alternatively), with the SEL key go to CODE PED LED 
when flashing and  press  the SET key: the CODE PED LED 
turns on and programming is completed. In this way the control 
unit will send a closing command to the motor every 2 hours for 
2   seconds.   Repeat   the   operation   to   restore   the   previous 
configuration. 

D)  INB. CMD. AP (Electronic Brake):

The   control   unit   is   supplied   by   the   manufacturer   with   the 
electronic brake function not enabled. To enable the function 
follow this procedure: check that the extended menu is enabled 
(T. MOT. and T. PAUSA LED’s start flashing alternatively), with 
the SEL key go to INB. CMD. AP. LED when flashing and press 
the SET key: the INB. CMD. AP. turns on and programming is 
completed. The control unit reduces the forward motion of the 
gate   due   to   inertia   in   the   presence   of   a   stop   or   inversion 
command.   Repeat   the   operation   to   restore   the   previous 
configuration. 

E)  LAMP/CORT/CO (Closure Strike) :

The control unit is supplied with the closure strike function not 
enabled. To enable the function follow this procedure: check 
that the extended menu is enabled (T. MOT. and T. PAUSA 
LED’s   start   flashing   alternatively),   with   the   SEL   key   go   to 
LAMP/CORT/CO LED when flashing and press the SET key: 
the   LAMP/CORT/CO   LED   turns   on   and   programming   is 
completed. If programmed with deceleration during closing, the 
control unit will add a 1-second time at maximum power (after 
completing the decelerated closing operation) to overcome the 
lock,   if   any.     Repeat   the   operation   to   restore   the   previous 
configuration. 

RESET :

To reset the default configuration, press the SEL and SET keys 
simultaneously, all 

RED 

LED’s will turn on and then off. 

DIAGNOSTICS: 

Photoelectric Cells Test:

The   control   unit   is   set   for   the   connection   of   safety   devices 
compliant with 5.1.1.6 section of EN 12453. The operation test 
of   connected   photoelectric   cells   is   performed   at   each 
manoeuvring   cycle.   In   case   of   no   connection   and/or   no 
operation, the control unit will not enable movement and will 
visually indicate the test failure with simultaneous flashing of all 
LED’s. Once the correct operation of the photoelectric cells has 
been   restored,   the   control   unit   is   ready   for   operation.   This 
guarantees   monitoring   against   failures   in   compliance   with 
Category 2 of EN 954-1.

Command input test:

The control unit is provided with a LED for each low voltage 
command input to monitor the status immediately. 
Operation   principle:  LED  on  =  input  closed,  LED off  =  input 
open.

Summary of Contents for LRX 2186

Page 1: ... The selection of this operation mode is described in the Pause Time programming mode Pedestrian Passage Using both the pedestrian radio control CODE PED LED on and the low voltage push button station PED to control the shutter the following operation is obtained the first impulse controls opening for 10 seconds then the control unit makes a 10 second pause and closes the shutter Safety device The...

Page 2: ... restore the previous configuration 5 LAMP CORT CO Selection of flashing beacon courtesy light or auxiliary contact The control unit is provided with a clean relay contact output to connect a flashing beacon courtesy light or auxiliary contact i e for garage light command The control unit is supplied by the manufacturer with the flashing beacon function enabled To enable the courtesy light follow ...

Page 3: ...manufacturer with the maintenance of hydraulic motor pressure not enabled To enable the function follow this procedure check that the extended menu is enabled T MOT and T PAUSA LED s start flashing alternatively with the SEL key go to CODE PED LED when flashing and press the SET key the CODE PED LED turns on and programming is completed In this way the control unit will send a closing command to t...

Page 4: ...453 The D S Power Supply output must be dedicated to photoelectric cell power supply It must not be used for other applications The control unit tests the operation of photoelectric cells at every manoeuvring cycle to guarantee protection against failures of anti compression devices of Category 2 in compliance with section 5 1 1 6 of EN 12453 Therefore it safety devices are not connected and or op...