background image

 

Rev. 1.2    21/05/07

 

P

ROGRAMMING WITH OTHER 

R

ADIO 

C

ONTROLS  

The  above  programming  operations  can  be  repeated  to  enter  further 
radio  control  codes  -  up  to  a  maximum  of  75  -  in  the  control  unit 
memory. 

 

If the memory already contains 75 stored codes when you attempt the 
programming  procedure,  the  control  unit  will  beep  six  times  to  inform 
you that the memory is full. 

I

NVERSION OF THE ROTATION MOTOR

 

If you notice that when pressing the ( Up ) key on the radio-control the 
control  unit  causes  the  shutter  to  move  downwards  instead  of 
upwards,  simply  repeat  the  programming  procedure  pressing  the  ( 
Down ) key instead of the ( Up ) key, or invert the Upward movement 
wire and the Downward movement wire of the motor. 

P

ROGRAMMING 

V

ENETIAN 

B

LIND 

O

PERATION 

To  activate  this  operating  mode,  move  the  jumper  J1  (located  on  the 
board,  inside  the  plastic  container)  from  position  2-3  to  position  1-2. 
Perform this procedure with the control unit disconnected from the 230 
V electricity supply. 

P

ROGRAMMING 

“U

SER 

P

RESENT

 

B

LIND 

O

PERATION 

To activate this operating mode, remove the jumper J1 (located on the 
board,  inside  the  plastic  container).  Perform  this  procedure  with  the 
control unit disconnected from the 230 V electricity supply. 

P

ROGRAMMING 

I

NDEFINITE 

M

OTOR 

T

IME

 

To  set  unlimited  motor  time  proceed  as  follows:  press  and  hold  the 
SEL button while the control unit is connected to the electricity supply, 
until  the  control  unit  emits  seven  confirmation  beeps.  To  restore  the 
three-minute motor running time, repeat the operation described above 
or perform the Reset procedure. 

R

ESET WITH THE 

“SEL”

 BUTTON

 

To  restore  the  control  unit  to  its  default  configuration,  proceed  as 
follows. press and hold the SEL button for 5 seconds, until the control 
unit beeps five times to confirm that the operation is complete. 

B

EEP 

S

IGNALS

 

1 BEEP  = First radio control code stored. 
2 BEEPS  = Second radio control code stored. 
3 BEEPS  = Start of programming phase. 
4 BEEPS  = End of programming phase. 
5 BEEPS  = Restoration of default configuration. 
6 BEEPS  = No more memory available for new codes. 
7 BEEPS  = Motor running time programming. 
 
 
 

F

OR THE 

U

SER 

-

 

I

MPORTANT

 

 
-  The  device  should  not  be  used  by  children  or  by  individuals  with 
reduced  physical  or  psychological  abilities  unless  supervision  is 
provided or instruction given on how to operate it. 
-  Do  not  let  children  play  with  the  device;  keep  radio  controls  out  of 
their reach. 
-  CAUTION:  Keep  this  instruction  manual  in  a  safe  place  and  adhere 
to the important safety instructions contained within it. Non-adherence 
to  these  instructions  may  lead  to  property  damage  and  serious 
accidents.
 
- Examine the system frequently to check for any signs of damage. Do 
not use the device if it needs to be repaired. 
 
- If the wires have to be replaced (for the power supply or for the motor 
output), contact a qualified technician only.
 
 
 

F

OR THE 

I

NSTALLER 

-

 

I

MPORTANT

 

 

The control unit was designed to enable the installer to automate 
closure while adhering to the provisions set out by current legislation. 
Compliance with these obligations and the implementation of the 
minimum safety requirements is the responsibility of the installer. Once 
installation has been completed in full compliance with EN 60335-2-97 
(“Household and similar electrical appliances - Safety”, part 2 
“Particular requirements for drives for rolling shutters, awnings, blinds 
and similar equipment”), make sure that:

 

 

There are no accidental movements. 

 

There are no movements which were not requested caused 
by variations in the voltage and electricity supply. 

 

The force of impact at the main closure edge does not 
exceed: 

         - 25 N for more than 5 s 

- 150 N for more than 0.5 s. 

 If the latter provision is not satisfied, the “User Present” 
function can be used as an alternative, to obtain non self-
holding release command operation. In this case the radio 
control must only be used while  
the user is in full view of the rolling device (perhaps  
fixing it to the wall would ensure this).     

 

 
We also advise that you take note of the following recommendations:
       

 

-   For the radio receiver to operate correctly when two or more control 

units are used, we recommend that you install the devices at least 3 
metres away from each other. 

 

The  control  unit  is  not  equipped  with  a  sectioning  device.  The 

installer  is  therefore  responsible  for  the  installation  of  a  sectioning 
device in the system.

 

 

 

SEAV s.r.l. hereby declares that the product below: 

LRS 2200 / M - LRS 2200 / M SET  

Electronic Control Unit 

 

Comply  with  the  requirements  of  Directives  R&TTE  99/5/EC,       
EMC 2004/108/EC,  LVD 2006/95/EC. 
 

 

 