2
Rev. 1.2 21/05/07
P
ROGRAMMING WITH OTHER
R
ADIO
C
ONTROLS
The above programming operations can be repeated to enter further
radio control codes - up to a maximum of 75 - in the control unit
memory.
If the memory already contains 75 stored codes when you attempt the
programming procedure, the control unit will beep six times to inform
you that the memory is full.
I
NVERSION OF THE ROTATION MOTOR
If you notice that when pressing the ( Up ) key on the radio-control the
control unit causes the shutter to move downwards instead of
upwards, simply repeat the programming procedure pressing the (
Down ) key instead of the ( Up ) key, or invert the Upward movement
wire and the Downward movement wire of the motor.
P
ROGRAMMING
V
ENETIAN
B
LIND
O
PERATION
To activate this operating mode, move the jumper J1 (located on the
board, inside the plastic container) from position 2-3 to position 1-2.
Perform this procedure with the control unit disconnected from the 230
V electricity supply.
P
ROGRAMMING
“U
SER
P
RESENT
”
B
LIND
O
PERATION
To activate this operating mode, remove the jumper J1 (located on the
board, inside the plastic container). Perform this procedure with the
control unit disconnected from the 230 V electricity supply.
P
ROGRAMMING
I
NDEFINITE
M
OTOR
T
IME
To set unlimited motor time proceed as follows: press and hold the
SEL button while the control unit is connected to the electricity supply,
until the control unit emits seven confirmation beeps. To restore the
three-minute motor running time, repeat the operation described above
or perform the Reset procedure.
R
ESET WITH THE
“SEL”
BUTTON
To restore the control unit to its default configuration, proceed as
follows. press and hold the SEL button for 5 seconds, until the control
unit beeps five times to confirm that the operation is complete.
B
EEP
S
IGNALS
1 BEEP = First radio control code stored.
2 BEEPS = Second radio control code stored.
3 BEEPS = Start of programming phase.
4 BEEPS = End of programming phase.
5 BEEPS = Restoration of default configuration.
6 BEEPS = No more memory available for new codes.
7 BEEPS = Motor running time programming.
F
OR THE
U
SER
-
I
MPORTANT
- The device should not be used by children or by individuals with
reduced physical or psychological abilities unless supervision is
provided or instruction given on how to operate it.
- Do not let children play with the device; keep radio controls out of
their reach.
- CAUTION: Keep this instruction manual in a safe place and adhere
to the important safety instructions contained within it. Non-adherence
to these instructions may lead to property damage and serious
accidents.
- Examine the system frequently to check for any signs of damage. Do
not use the device if it needs to be repaired.
- If the wires have to be replaced (for the power supply or for the motor
output), contact a qualified technician only.
F
OR THE
I
NSTALLER
-
I
MPORTANT
The control unit was designed to enable the installer to automate
closure while adhering to the provisions set out by current legislation.
Compliance with these obligations and the implementation of the
minimum safety requirements is the responsibility of the installer. Once
installation has been completed in full compliance with EN 60335-2-97
(“Household and similar electrical appliances - Safety”, part 2
“Particular requirements for drives for rolling shutters, awnings, blinds
and similar equipment”), make sure that:
There are no accidental movements.
There are no movements which were not requested caused
by variations in the voltage and electricity supply.
The force of impact at the main closure edge does not
exceed:
- 25 N for more than 5 s
- 150 N for more than 0.5 s.
If the latter provision is not satisfied, the “User Present”
function can be used as an alternative, to obtain non self-
holding release command operation. In this case the radio
control must only be used while
the user is in full view of the rolling device (perhaps
fixing it to the wall would ensure this).
We also advise that you take note of the following recommendations:
- For the radio receiver to operate correctly when two or more control
units are used, we recommend that you install the devices at least 3
metres away from each other.
−
The control unit is not equipped with a sectioning device. The
installer is therefore responsible for the installation of a sectioning
device in the system.
SEAV s.r.l. hereby declares that the product below:
LRS 2200 / M - LRS 2200 / M SET
Electronic Control Unit
Comply with the requirements of Directives R&TTE 99/5/EC,
EMC 2004/108/EC, LVD 2006/95/EC.