Seav LG 2060 New Reader Instruction Manual Download Page 2

                                                                                                 2                                                            rev. 3.0   13/06/2016 

 

TECHNICAL DATA: 

 

- Power supply                 : 230 Vac  50-60Hz  900W (4A) max. 
- Flashing light output                 : 230 Vac 50-60 Hz  
                                                    100W Resistive Load max. 
                                                      50W Inductive Load max. 
- Motor output                           : 230 Vac 50-60Hz 750 W max. 
- Services power supply output   : 24 Vac 3 W max. 
- Safety devices and controls in BT: 24 Vdc 
- Operating temperature           :  -10 

÷

 55 °C 

- Radio receiver                        : 433.92 Mhz  “narrow band” 
- Op. transmitters                      : 12-18 Bit or Rolling Code 
- No. of devices that can be stored   : 120 max. 
- Board dimensions                 : 100x105 mm. 
- Dimensions of container                  : 110x121x47 mm. 
- Container: ABS V-0  ( IP54 ). 

 

TERMINAL BOARD CONNECTIONS: 

 

CN1 : 
 1  : 230 Vac line input (Phase). 
 2  : 230 Vac line input (Neutral) 
 3  : 230 Vac Flashing light Output (Neutral).  
 4  : 230 Vac Flashing light Output (Phase).  
 5  : Opening 230V Motor Output. 
 6  : Common 230V Motor Output. 
 7  : Closing 230V Motor Output. 
CN2: 

  1 : 

Motor Opening Limit Switch Input (NC). 

  2 : Common GND input. 
  3 : Motor Closing Limit Switch Input (NC). 
  4 : Power supply to photocells ( 24Vac 3W). 
  5 : Power supply to photocells (GND). 
  6 : Control button input (NA). 
  7 : Common GND input 
  8 : Safety device input (NC). 
  9 : Aerial earth input. 
10  : Aerial hot pole input. 
CN3 :  
1   : Power supply output 12 VDC Device. 
2   : Communication port RS 485 signal A. 
3   : Communication port RS 485 signal B. 
4   : Power supply output 0 VDC Device. 

 

OPERATING FEATURES: 
   
Step-by-step operation: 
By  using  either  the  Radio  Control,  Transponder,  Digital 
keyboard,  Smartphone  or  the  low  voltage  buttons  to  activate 
the frame, you obtain the following action: 
the  first  impulse  activates  the  opening  mechanism  until  the 
motor  time  expires  or  the  opening  limit  switch  is  reached,  the 
second  impulse  closes  the  gate.  If  an  impulse  is  sent  before 
the motor time expires or one of the two end runs are reached, 
the control unit will stop both opening and closing movements. 
An additional control re-starts motion in the opposite direction. 
 
Operating Mode using Radio Control, 
Transponder, Digital keyboard and Smartphone: 
The  receiver  can  be  combined  with  Radio  Controls, 
Transponders,  Digital  Keyboards,  Smartphones  and  stores  up 
to 120 different users. 
For  use  with  radio  controls,  the  receiver  unit  is  equipped  with 
an  incorporated  receiver;  for  use  of  the  other  devices,  the 
desired  accessory  must  be  connected  (by  carefully  following 
the  connection  diagrams  described  in  the  relative  operating 
manuals) supplied as optionals. 

Operation with different radio control models:  
Different  radio  control  models  can  be  programmed:  store  one 
code (1 key) for Step-by-Step cyclic operation (Opening - Stop - 
Closing); store two different codes (2 keys) for  
separate  controls,  the  first  for  Opening  and  the  second  for 
Closing;  store  one  code  (3  "BeFree  series"  keys)  for  three 
separate controls, the first for  
Opening, the second for Stop and the third for Closing. 
 
Radio control operation with 1 Key: 

 

Using the radio control with only one key, the following function 
is  obtained:  the  first  impulse  commands  Opening  until  the 
motor time expires. The second impulse commands Closing of 
the  frame.  If  an  impulse  occurs  before  the  motor  time expires, 
the  control  unit  stops  the  frame.  A  further  impulse  implements 
the re-starting of the motion in the opposite direction. 
 
Radio control operation with 2 Keys: 

 

Using  the  radio  control  with  2  keys,  the  following  function  is 
obtained:  the  first  key  ("Up"  associated  to  the  Opening 
direction) commands Opening until the motor time expires, and 
the  second  key  ("Down"  associated  to  the  Closing  direction) 
commands  Closing  of  the  frame.  If  the  Up  command  is  given 
again  during  Opening,  the  control  unit  continues  the  Opening 
motion,  while  if  a  Down  command  is  given,  the  control  unit 
stops motion. 
The same procedure is valid during the Closing phase. 
 
Radio control operation with 3 Keys (BeFree series): 
Using the BeFree series radio controls, the following function is 
obtained:  the  Up  key  commands  Opening  until  the  motor  time 
expires,  the  Stop  key  commands  Stop,  and  the  Down  key 
commands Closing of the frame. If during opening or closing a 
Stop  command  is  given,  the  control  unit  commands  the  frame 
to stop. If during opening or closing the command opposite the 
present motion is given, the control unit commands to run in the 
opposite direction. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for LG 2060 New Reader

Page 1: ...relevant support which is fitted to the casing in such a way as to leave said support facing downwards and insert the fixing screws in the special holes 7 The control unit does not have any type of isolating device for the 230 Vac line It is therefore the responsibility of the installer to set up an isolating device inside the system It is necessary to install an omnipolar switch surge category II...

Page 2: ...l Keyboards Smartphones and stores up to 120 different users For use with radio controls the receiver unit is equipped with an incorporated receiver for use of the other devices the desired accessory must be connected by carefully following the connection diagrams described in the relative operating manuals supplied as optionals Operation with different radio control models Different radio control...

Page 3: ... with 3 Keys The control unit can store the whole BeFree radio control by programming only the UP Key The BeFree radio control codes are programmed as follows press the SEL key the CODE LED will start flashing at the same time press the UP key of the desired radio control the CODE LED will remain on and programming will be complete Deletion All the stored devices are deleted as follows press the S...

Page 4: ...her the Radio Control Transponder Digital keyboard Smartphone or the low voltage push button panel to operate the frame you will obtain the following function the first impulse commands opening until the motor time expires the second impulse commands frame closing If an impulse is sent before the motor time expires the control unit changes the direction of motion in the opening and closing phases ...

Page 5: ...t means the input is closed when a LED is off it means the input is open MANAGING PROGRAMMING LEDS After 3 minutes of inactivity in the programming procedure the control unit will automatically switch off the programming LEDs to save energy The LEDs will light up depending on the previously set programs only when the SEL or SET keys are pressed or when a motion command has been received ...