TECHNICAL DATA:
- Power supply : 230 Vac 50-60Hz 900W (4A) max.
- Flashing light output : 230 Vac 50-60 Hz
100W Resistive Load max.
50W Inductive Load max.
- Motor output : 230 Vac 50-60Hz 750 W max.
- Services power supply output : 24 Vac 3 W max.
- Safety devices and controls in BT: 24 Vdc
- Operating temperature : -10
÷
55 °C
- Radio receiver : 433.92 Mhz “narrow band”
- Op. transmitters : 12-18 Bit or Rolling Code
- No. of devices that can be stored : 120 max.
- Board dimensions : 100x105 mm.
- Dimensions of container : 110x121x47 mm.
- Container: ABS V-0 ( IP54 ).
TERMINAL BOARD CONNECTIONS:
CN1 :
1 : 230 Vac line input (Phase).
2 : 230 Vac line input (Neutral)
3 : 230 Vac Flashing light Output (Neutral).
4 : 230 Vac Flashing light Output (Phase).
5 : Opening 230V Motor Output.
6 : Common 230V Motor Output.
7 : Closing 230V Motor Output.
CN2:
1 :
Motor Opening Limit Switch Input (NC).
2 : Common GND input.
3 : Motor Closing Limit Switch Input (NC).
4 : Power supply to photocells ( 24Vac 3W).
5 : Power supply to photocells (GND).
6 : Control button input (NA).
7 : Common GND input
8 : Safety device input (NC).
9 : Aerial earth input.
10 : Aerial hot pole input.
CN3 :
1 : Power supply output 12 VDC Device.
2 : Communication port RS 485 signal A.
3 : Communication port RS 485 signal B.
4 : Power supply output 0 VDC Device.
OPERATING FEATURES:
Step-by-step operation:
By using either the Radio Control, Transponder, Digital
keyboard, Smartphone or the low voltage buttons to activate
the frame, you obtain the following action:
the first impulse activates the opening mechanism until the
motor time expires or the opening limit switch is reached, the
second impulse closes the gate. If an impulse is sent before
the motor time expires or one of the two end runs are reached,
the control unit will stop both opening and closing movements.
An additional control re-starts motion in the opposite direction.
Operating Mode using Radio Control,
Transponder, Digital keyboard and Smartphone:
The receiver can be combined with Radio Controls,
Transponders, Digital Keyboards, Smartphones and stores up
to 120 different users.
For use with radio controls, the receiver unit is equipped with
an incorporated receiver; for use of the other devices, the
desired accessory must be connected (by carefully following
the connection diagrams described in the relative operating
manuals) supplied as optionals.
Operation with different radio control models:
Different radio control models can be programmed: store one
code (1 key) for Step-by-Step cyclic operation (Opening - Stop -
Closing); store two different codes (2 keys) for
separate controls, the first for Opening and the second for
Closing; store one code (3 "BeFree series" keys) for three
separate controls, the first for
Opening, the second for Stop and the third for Closing.
Radio control operation with 1 Key:
Using the radio control with only one key, the following function
is obtained: the first impulse commands Opening until the
motor time expires. The second impulse commands Closing of
the frame. If an impulse occurs before the motor time expires,
the control unit stops the frame. A further impulse implements
the re-starting of the motion in the opposite direction.
Radio control operation with 2 Keys:
Using the radio control with 2 keys, the following function is
obtained: the first key ("Up" associated to the Opening
direction) commands Opening until the motor time expires, and
the second key ("Down" associated to the Closing direction)
commands Closing of the frame. If the Up command is given
again during Opening, the control unit continues the Opening
motion, while if a Down command is given, the control unit
stops motion.
The same procedure is valid during the Closing phase.
Radio control operation with 3 Keys (BeFree series):
Using the BeFree series radio controls, the following function is
obtained: the Up key commands Opening until the motor time
expires, the Stop key commands Stop, and the Down key
commands Closing of the frame. If during opening or closing a
Stop command is given, the control unit commands the frame
to stop. If during opening or closing the command opposite the
present motion is given, the control unit commands to run in the
opposite direction.