Seav BeWeather Manual Download Page 3

the SET key once the desired threshold has been reached – at 
this moment, the selected value will be stored and the WIND 
LED will remain lit (

for example: 5 WIND LED double-flashes =  

25 km/h).

The operation may be repeated if a mistake is made during 
programming.

4)

SUN SENSOR 

( Sun Sensor ON/OFF )

Enabling the Sun Sensor

The  control  unit  comes  with  the Sun  Sensor  disabled   (SUN 
SENSOR LED OFF).
The Sun Sensor may be enabled in the following way: press 
the SEL key until the SUN SENSOR LED flashes, then press 
the SET key briefly; at this moment the SUN SENSOR LED 
remains  lit and the Sun Sensor  will be enabled. Repeat  the 
operation to disable the Sun Sensor.

Enabling  the Sun Sensor  using a 3-button radio control  
(BeFree x3 - X6):

The Sun Sensor may be enabled  in the following way: hold 
down the (+) key on the radio control that was programmed 
previously for 5 seconds; at the same time the control unit will 
cause the shutter to move Up/Down for 1 second to confirm 
that the Sun Sensor has been enabled, and the SUN SENSOR 
LED will remain lit. Repeat the operation to disable the Sun 
Sensor by following the same procedure, but instead holding 
down the (-) key for 5 seconds.

5)

RAIN SENSOR 

( Rain Sensor ON/OFF )

Disabling the Rain Sensor

The control unit comes with the Rain Sensor enabled (RAIN 
SENSOR LED ON).
The Rain Sensor may be disabled in the following way: press 
the SEL key until the RAIN SENSOR LED flashes, then press 
the SET key briefly; at this moment the RAIN SENSOR LED 
switches off and  the Rain Sensor  will be disabled. You can 
repeat the operation to enable the Rain Sensor.

EXTENDED MENU

The control unit is supplied by the manufacturer with the option 
of selecting only the functions listed in the main menu.
To   enable   the   functions   of   the   extended   menu   proceed   as 
follows: press the SET key and hold for 5 seconds; the SUN, 
RAIN   and   R.   HEAT   LEDs   will   flash   and   the   user   has   30 
seconds within which to select the functions of the extended 
menu using the SEL and SET keys. After another 30 seconds 
the control unit returns to the main menu.

---------------------- EXTENDED MENU -----------------

Reference LED                LED Off                              LED On

A) CODE           remote PGM = OFF                      remote PGM = ON
B) T. MOT.        Aut. movement lock = OFF    Aut. movement lock = 
ON
C) WIND SPEED    Safety upward = OFF             Safety upward = 
ON                   
D) SUN SENSOR    RAIN inversion = OFF           RAIN inversion = 
ON                
E) RAIN SENSOR  Aut. movements 5 min.       Aut. Movements 10 
min.
C) SUN                                    Flashing beacon ON/OFF
C) RAIN                                   Flashing beacon ON/OFF
G) R. HEAT                             Flashing beacon ON/OFF

A) CODE
(Remote programming of radio control):

The   control   unit   allows   the   transmission   code   to   be 
programmed by remote, without using the SEL key.
To   programme   the   transmission   code   remotely,   proceed   as 
follows: send the radio control code continuously for more than 
10   seconds   and   the  control   unit   will  enter  the   programming 
mode   as   described   above   for   the   CODE   LED   in   the   main 
menu.
The control unit is supplied by the manufacturer with remote 
programming of the transmission code not enabled; to enable 
the function proceed as follows: check that the extended menu 

is enabled (SUN, RAIN and R. HEAT LEDs flash), using the 
“SEL” key navigate to CODE LED when flashing and press the 
“SET”   key:   the   CODE   LED   lights   up   permanently   and 
programming is completed. Repeat the operation to restore the 
previous configuration.

B) T. MOT.  (Automatic movement lock):

The   control   unit   enables   the   prevention   of   Automatic 
movements   (Up   /   Down   sun   blind   movements   on   the   Sun 
Sensor command or Automatic Sensors function), so that if a 
Stop   command   is   sent   from   a   radio   control   during   the 
movement,  the  control   unit  momentarily  locks  the  Automatic 
movements  until  a new  Up  or  Down command is  sent.   The 
control unit is supplied by the manufacturer with the Automatic 
Movement Lock disabled; to enable the function proceed as 
follows: check that the extended menu is enabled (SUN, RAIN 
and R. HEAT LEDs flash), using the “SEL” key navigate to T. 
MOT.   LED   when   flashing   and   press   the   “SET”   key:   the   T. 
MOT.   LED   lights   up   permanently   and   programming   is 
completed.   Repeat   the   operation   to   restore   the   previous 
configuration.

C) WIND  ( Safety Upward Movement ) :

The control unit is supplied by the manufacturer with the Safety 
upward movement function disabled; if you wish to enable the 
function, in such a way that after 12 hours of inactivity of the 
Wind Sensor the control unit automatically control the safety 
upward   movement,   proceed   as   follows:   check   that   the 
extended menu is enabled (SUN, RAIN and R. HEAT LEDs 
flash),   using   the   “SEL”   key   navigate   to   WIND   LED   when 
flashing   and   press   the   “SET”   key:   the   WIND  LED   lights   up 
permanently   and   programming   is   completed.   Repeat   the 
operation to restore the previous configuration.

D) SUN SENSOR  ( Rain control movement inversion ) :

The control unit is supplied by the manufacturer with the Rain 
Control  = Upward Movement Control association, that is to say 
when the rain sensor detects the rain, the control unit controls 
the upward movement. If you wish that the control unit controls 
the   downward   movement   when   rain   is   detected   by   the   rain 
sensor, proceed as follows: check that the extended menu is 
enabled   (SUN,   RAIN   and   R.   HEAT   LEDs   flash),   using   the 
“SEL” key navigate to SUN SENSOR LED when flashing and 
press   the   “SET”   key:   the   SUN   SENSOR   LED   lights   up 
permanently   and   programming   is   completed.   Repeat   the 
operation to restore the previous configuration.

E) RAIN SENSOR (Automatic sensor action Time) :

The   control   unit   is   supplied   by   the   manufacturer   with   the 
Automatic sensor action Time of 4 minutes; if you wish to set 
10   minutes   to   reduce   the   motor   movements,   proceed   as 
follows: check that the extended menu is enabled (SUN, RAIN 
and   R. HEAT LEDs  flash),  using  the  “SEL”  key  navigate  to 
RAIN SENSOR LED when flashing and press the “SET” key: 
the   RAIN   SENSOR   LED   lights   up   permanently   and 
programming is completed. Repeat the operation to restore the 
previous configuration.

R

ESET

To reset the default configuration of the control unit, press the 
SEL and SET buttons simultaneously; all indicator

 

LEDs will 

switch on and then off again immediately.

3

Rev. 1.2      31/01/08

Reviews: