INSTALLATION (Continued)

5

LAWN SPRINKLING APPLICATION

This pump is designed for lawn sprinkling. It is designed to
deliver plenty of water at full sprinkler pressure. It can pump
from a pond, cistern or well points.
Pump discharge can be divided to supply two (2) or more
sprinkler systems. A suggested multiple discharge to service
is shown in Figure 7.

Do not use in a pressure tank or booster pump appli-
cation.

Pump/Piping Installation

PUMP INSTALLATION

NOTICE: 

Use Teflon tape supplied with the pump for mak-

ing all threaded connections to the pump itself. 

Do not use

pipe joint compounds on the pump:

they can react with

the plastic in the pump components.
1. Bolt pump to solid, level foundation.
2. Support all piping connected to the pump.

3. Wrap 1-1/2 to two layers of Teflon tape clockwise (as you

face end of pipe) on all male threads being attached to
pump.

4. Tighten joints hand tight plus 1-1/2 turns. 

Do not over-

tighten.

NOTICE:

Install pump as close to water source as possible.

Long piping runs and many fittings create friction and re-
duce flow.
Use schedule 80 or iron pipe. See “Well Pipe Installation” for
more information.

P

846 0494

Gate
Valve

Check
Valve

To 
Service

Priming
Plug

Figure 7 – Multiple Discharge

P

843 0494

P

841 0494

Figure 8 – Bolt Pump Down

Figure 9 – Independently Support All Piping 
Attached To Pump

TABLE II – PERFORMANCE CHART (IN GALLONS PER MINUTE)

390.262452

390.262552

390.262652

DISCHARGE

1 H.P.

1-1/2 H.P.

2 H.P.

PRESSURE

DISTANCE ABOVE TO WATER

PSI

5’

10’

15’

20’

5’

10’

15’

20’

5’

10’

15’

20’

10

55

49

48

45

67

61

56

46

69

67

65

62

15

51

46

45

44

66

58

55

45

65

63

60

58

20

45

42

39

37

61

56

54

44

59

56

54

52

25

38

35

32

29

55

52

51

43

52

50

48

45

30

31

28

24

20

48

45

44

37

47

45

42

40

35

23

19

16

11

39

37

34

28

42

38

35

32

40

17

13

8

33

27

20

11

34

30

27

23

45

18

14

8

25

18

13

10

50

14

7

DISCHARGE

PIPE TAPPING

1-1/2” NPT

1-1/2” NPT

2” NPT

SUCTION

PIPE TAPPING

1-1/2” NPT

1-1/2” NPT

2” NPT

Summary of Contents for HYDRO-GLASS 390.262452

Page 1: ...Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair...

Page 2: ...art fires 5 Disconnect electrical power source before installing or working on pump 6 Ground pump with a ground wire run from grounding lug on motor to a grounded lead in the service panel 7 Line volt...

Page 3: ...void the warranty Check locally for frost protection requirements usually pipe must be 12 below frost line and pump must be insu lated 4 Be sure all pipes and foot valve are clean and in good shape 5...

Page 4: ...ON 1 Connect the suction pipe to the drive point as illustrated in Figure 6 Keep horizontal pipe run as short as possible Use Teflon tape on male pipe threads Multiple well points may be necessary to...

Page 5: ...pump 4 Tighten joints hand tight plus 1 1 2 turns Do not over tighten NOTICE Install pump as close to water source as possible Long piping runs and many fittings create friction and re duce flow Use...

Page 6: ...d copper wire at least as large as power sup ply wires Connect ground wire to grounded lead in service panel metal underground water pipe well casing at least 10 3M long or to ground electrode provide...

Page 7: ...tal run 10 of horizontal suction pipe 1 of vertical lift due to friction losses in the pipe If no water is produced within 10 minutes stop pump release all pressure remove priming plug refill and try...

Page 8: ...terminals together see Figure 18 Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a quali fied electrician 4 Unscrew capacitor clamp and remove capacitor Do not disconn...

Page 9: ...arbon face of seal when passing it over threaded shaft end or shaft shoulder The carbon surface must remain clean or short seal life will result 9 Hold motor shaft with 7 16 open end wrench on shaft f...

Page 10: ...and re prime If receding water level of pump in well exceeds suction lift a deep well pump is needed 3 Impeller is plugged 3 Clean impeller see Maintenance 4 Check valve or foot valve is stuck 4 Repla...

Page 11: ...784 2784 2784 7 Impeller C105 92PVB C105 92PBBB C105 214PFA Impeller Screw C30 51SS 8 Diffuser C1 258PCA C1 258PCA 8A Diffuser C1 274P 9 Screw 8 32 RH U30 869SS U30 869SS U30 542SS 1 and 1 1 2 HP 4 Re...

Page 12: ...reement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair S...

Reviews: