Grounding Outlet

If outlet is not grounded, install a copper wire (at least 14
gauge) from the outlet box, as shown in Figure 4, to a metal
cold water pipe. Use ground clamp on pipe.

IMPORTANT:

The cold water pipe you use as a ground

must have metal continuity to electrical ground. If continuity
is interrupted by plastic, rubber, or other electrical insula-
tors; such as hoses, fittings, washers or gaskets (including
water meter or pump), a metal bypass must be used. Any
electrically insulated connector should be jumped (as shown
in Figure 5), with a length of No. 4 wire clamped securely
at both ends.

Automatic Thermal Overload Protection

This pump motor has a built-in automatic thermal overload
protector. If the motor overheats, the protector will open
and cut off power to the motor before the heat damages it
internally. The overload will reset automatically and the
pump will restart after the pump cools down below the dan-
ger point.

DO NOT attempt to work on the pump or

motor if the overload seems to have tripped. The
motor may restart without warning at any time. You
could be injured and the pump damaged if it starts
when you are working on it.

DO NOT

attempt to repair a sump pump. Take it to SEARS

for service by a qualified technician.

GENERATOR SIZING

Below is the Engine-Generator Watt rating required to
power this pump motor. Any additional loads, such as lights,
must be added to the listed load and the generator sized ac-
cordingly. 

Pump

Minimum Watt

Motor HP

Rating of Generator

1/3

2,200

SERVICE

General

Risk of electric shock. When servicing

pump always disconnect power to electrical outlet
and remove pump electric cord from outlet. Inspect
sump pump and system components monthly. Keep
free of debris and foreign objects.

1. If pump does not operate:

a. Check for loose plug at electric outlet.

b. Check for blown fuses or tripped circuit breakers at

fuse box/circuit breaker box.

c. Be sure nothing interferes with action of float switch.

d. If a, b, and c above check OK, plug in a light that you

know works. If it lights, take your pump to SEARS for
service. If it doesn’t light, the electrical circuit is faulty;
consult a licensed electrician.

2. Pump starts, but blows fuses/trips circuit breakers:

After disconnecting power to pump, remove it from
sump. Remove the plate from the bottom of the pump
and make sure that the impeller turns freely. Remove any
debris obstructing impeller. If pump still does not oper-
ate correctly, return it to your nearest SEARS Service
Department for repairs.

3. Pump runs, but does not empty sump:

a. Clean pump intake screen.

b. Water may be entering sump faster than the pump can

discharge it.

c. Be sure vertical distance from pump discharge outlet

to discharge pipe outlet is 18 feet or less.

d. Be sure discharge pipe is not plugged or frozen.

LUBRICATION

Motor has been lubricated at the factory. It does not require
additional oil. Bronze bearing in volute housing is oil im-
pregnated. It does not require additional oil.

5

669 0194

Bare copper wire to

cold water pipe.

Outlet

Box

Meter

Metal Water

Pipe

Clamp

No. 4

Wire

670 0194

Figure 4

Figure 5

Summary of Contents for Craftsman 390.303302

Page 1: ...Rules and Operating Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Operation Installation S...

Page 2: ...serious bodily injury and or property damage 2 Check your local Electrical and Plumbing Codes before installing pump You must comply with their rules Do not use in explosive atmospheres Pump water on...

Page 3: ...ectrical and Plumbing Codes before in stalling pump You must comply with their rules Set the pump on the bottom of the sump making sure that it sits solidly and is level Be sure there is enough space...

Page 4: ...od The buoyancy will push the switch arm up and turn the switch on 3 When the water is pumped out of the sump the float drops down again The weight of the float will allow the rod and switch arm to lo...

Page 5: ...ly Pump Minimum Watt Motor HP Rating of Generator 1 3 2 200 SERVICE General Risk of electric shock When servicing pump always disconnect power to electrical outlet and remove pump electric cord from o...

Page 6: ...n 1 Motor 2 Switch 3 PS1 25P Volute Pump Body 4 PS5 21P Impeller 5 PS4 17P Base Plate 6 U30 934ZP Screws Base Plate 7 RP0005249 Float Rod Guide 8 U30 929ZP Screw Guide Rod 9 SC004 116 Screw Base 10 FT...

Page 7: ...7 Replacement Switches Switch FP0020 Switch 2773...

Page 8: ...ssional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Ho...

Reviews: