background image

REPAIR PARTS

7

10

12

11

13

14

15

16

17

18

22

20

19

21

1

2

3

2

3

4

5

4

5

6

7

8

9

23

2389 0496

Key
No.

Part Number

Part Description

Qty.

1

101P3410

Pump Body

1

2

111P0710

Drain/Priming Port O-Ring

2

3

102P1030

Drain/Fill Cap

2

4

111P0370

Hose Adapter O-Ring

2

5

101P3460

Garden Hose Adapter

2

6

111P0480

Venturi O-Ring

1

7

102P2840

Venturi/Diffuser

1

8

731S5700

Impeller

1

9

ZBR00010

Shaft Seal - Complete

1

10

111P0700

Pump Body O-Ring

1

11

101P1290

Seal Plate

1

12

*

Motor 1

13

121P0090

Flat Washer

1

14

121P0920

Lock Washer

1

15

121P1280

Ground Screw

1

16

102P2010

Fan (Includes Key No. 17)

1

17

121R2240

Fan Clip

1

18

721S1030

Fan Cover

1

19

751S3230

Motor Housing (Complete)

1

20

121P1500

Washer for Housing Screw

1

21

121P4180

Housing Screw

1

22

171P5740

Capacitor – 30 microfarad

1

23

121P1940

Cap Screw

6

ZB400960

Suction Hose Kit with

1” Foot Valve and Strainer

1

ZA000020

Foot Valve and Strainer - 1”

1

To order parts, call:

Sears Product Service,

1-800-366-7278

• Not illustrated.     * If motor fails, replace entire pump.

Summary of Contents for CRAFTSMAN 390.260293

Page 1: ...Operating Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Installation Operation Maintenance Repair Parts PRINTE...

Page 2: ...not allow any part of cord or receptacle ends to sit in water or damp locations Unplug pump before servicing Hazardous pressure Pump body may ex plode if used as a booster pump unless re lief valve c...

Page 3: ...ke sure there are no air leaks or air pockets in suction pipe Boosting City Water Pressure Hazardous pressure When using garden hose as a discharge line do not run pump with hose outlet or nozzle clos...

Page 4: ...earings Pump seal is water cooled and self lubricating PUMP SERVICE Hazardous voltage Can shock burn or cause death Disconnect motor from elec trical power before servicing pump Motor has auto reset t...

Page 5: ...gure 5 Capacitor replacement Unplug pump before doing any work on it Discharge capacitor by shorting capacitor lead wires together before removing it Figure 6 Shroud replacement Unplug pump before doi...

Page 6: ...pump before working on it Make sure that you do not scratch nick or crack new seal Do not scratch or gouge pump shaft Make sure seal faces are clean when installing new seal Risk of electrical shock C...

Page 7: ...10 111P0700 Pump Body O Ring 1 11 101P1290 Seal Plate 1 12 Motor 1 13 121P0090 Flat Washer 1 14 121P0920 Lock Washer 1 15 121P1280 Ground Screw 1 16 102P2010 Fan Includes Key No 17 1 17 121R2240 Fan...

Page 8: ...bout an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES...

Reviews: