7-16
Normal:
High Speed: Approximately
60 to 75 ohms
Low Speed: Approximately
115 to 125 ohms
Normal: Approximately
2.5 to 3.5 Kohms
Abnormal:
Infinite or several.
1. Remove lead wires.
2. Measure resistance.
(ohm meter scale: Rx1)
High Speed: BL & BK Wire
Low Speed: BL & WH Wire
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1000)
VENTILATION MOTOR
TURNTABLE MOTOR
1. Remove lead wires.
2. Measure resistance.
(ohm meter scale: Rx1)
Normal:
Approximately 120 to 135 ohms
Abnormal: Infinite
STIRRER MOTOR
COMPONENTS
TEST RESULTS