background image

Assembly / Installation / Operation / Maintenance

3

PUMP ASSEMBLY

Models 390.121800 and 390.122600 are pre-assem-
bled. For all other models, refer to Figures 1 thru 3 for
pump assembly as required by your model. Connections
are either slip fit or threaded, no epoxy or thread com-
pound is required.

INSTALLATION

1. Install pump on a hard level surface. Keep pump 

elevated from pond bottom to reduce maintenance.
Position pump so that fountain jet is just above sur-
face of water.

2. Protect pump power cord from damage. Uncovered

cords should be routinely inspected for damage or
deterioration. DO NOT operate pump if cord is dam-
aged.

3. Adjust diverter valve to control fountain spray height,

DO NOT restrict pump suction to accomplish this.
Refer to performance chart (Page 4) for maximum
fountain spray height for each individual model.
(When used as a fountain only).

4. Pumps connected to pond filters must be adjusted at

the diverter valve to provide adequate flow to the fil-
ter. Refer to filter instruction manual to determine
flow requirement of individual filter units.

5. Use hose clamps to secure tubing connected to

diverter valve fitting, pond filter or ornamental 
statuary.

OPERATION/MAINTENANCE

1. Pump is a submersible type and must be under water

at all times for proper operation and cooling.

Never run pump dry!

2. Clean inlet filter regularly. A clogged inlet filter will

reduce flow which can damage the pump.

NOTICE: Most pumps are equipped with a thermal pro-
tector that will shut pump off if operating temperature
becomes too high, possibly due to restricted flow, or a
clogged impeller. Pump will restart when the motor has
cooled sufficiently.
Periodically check to see that impeller rotation is not
being hampered by any debris and to clean internal
components.

Disassembly/Cleaning

Refer to exploded views, Pages 5 and 6, to match disas-
sembly procedure with the pump you have purchased.

Hazardous voltage. Disconnect power

before working on pump.

Models 390.121800 and 390.122600

1. Remove pump body (Key 1, Page 5) by gently turning

counter-clockwise and then pull away from motor.

2. Hand grip impeller assembly (Key 4, Page 5) and pull

straight out, being careful not to damage ceramic
shaft.

1/2" Hose

Connection

3/4" Hose

Connection

Plug

Fountain

Jet

Diverter

Valve

Pump

593 0395

Inlet Filter

Housing

FPWG-180FK
FPWG-260FK
FPWG-400FK
FPWG-620FK

Figure 1

1/2" Hose

Connection

3/4" Hose

Connection

Plug

Fountain

Jet

Diverter

Valve

Pump

Adapter

Inlet Filter

Housing

594 0395

FPWG-750FK
FPWG-960FK
FPWG-1130FK

1/2" Hose

Connection

3/4" Hose

Connection

Plug

1" Pipe Plug

Fountain

Jet

Diverter

Valve

Pump

Reducer

Bushing

Tee

Adapter

Inlet Filter

Housing

597 0395

FPWG-1340FK
FPWG-1560FK
FPWG-2100FK

Figure 2

Figure 3

390.131800
390.132600
390.134000
390.136200

390.137500
390.139600
390.131130

390.131340
390.131560
390.132100

Summary of Contents for 390.121800

Page 1: ...on Electrical Service Repair Parts 451 0395 Printed in England F642 9701FK 1 21 97 390 121800 390 122600 390 131800 390 132600 390 134000 390 136200 390 137500 390 139600 390 131130 390 131340 390 131...

Page 2: ...warns about hazards that will or can cause minor personal injury or property damage if ignored The label NOTICE indicates special instructions which are important but not related to hazards Carefully...

Page 3: ...y 2 Clean inlet filter regularly A clogged inlet filter will reduce flow which can damage the pump NOTICE Most pumps are equipped with a thermal pro tector that will shut pump off if operating tempera...

Page 4: ...by reversing above steps For Models 390 131800 and 390 132600 make sure flat on ceramic shaft passes through impeller first then turn until flat properly seats in motor housing Models 390 137500 thru...

Page 5: ...400FK 620FK 6 5 568 0395 Key 390 131800 390 132600 390 134000 390 136200 1 FPWG RP7 FPWG RP7 FPWG RP10 FPWG RP10 2 FPWG RP6 FPWG RP6 FPWG RP9 FPWG RP9 3 FPWG RP8 FPWG RP8 FPWG RP11 FPWG RP11 4 FPWG RP...

Page 6: ...A2 2 16520 16520 16520 3 16510 4 5 6 390 137500 390 139600 390 131130 390 131340 390 131560 390 132100 Accessories Key 390 137500 390 139600 390 131130 390 131340 390 131560 390 132100 1 FPWG RP16 FPW...

Page 7: ...7...

Page 8: ...27 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES OWNER S MANUAL Model...

Reviews: