Troubleshooting

Performance problems often result from little things that you can fix yourself.  Please read through this chart for a
possible solution if a problem occurs.

PROBLEM

POSSIBLE CAUSE

SOLUTION/REASONS

Green LED
does not light.

Charger not
charging battery.

Circuit breaker in
charger cycles on and
off with a clicking
sound.

Charger makes a
loud buzz or hum.

No AC power
reaching charger.

Wrong switch position
6V or 12V battery.

Poor connection at
battery.

Shorted battery clamps.

Shorted battery.

Charger leads reversed
on battery.

Check AC outlet.

Correct switch position and continue charging.

Unplug charger. Reconnect clips then plug in again
and continue charging.

Separate the clamps. Circuit breaker cycles when current
draw is too high.

Have a Sears technician test the battery.

Correct connections.

Transformer laminations
vibrate (buzz).

Shorted diode (hum).

Continue charging. Buzz is not abnormal.

Have charger tested by qualified technician.

If the above solutions do not eliminate the problem...

call toll-free from anywhere in the U.S.A.

1-800-SEARS-64

(1-800-732-7764)

7 AM to 4:30 PM CST Monday through Friday

Summary of Contents for 200.71201

Page 1: ...ANUAL Model No 200 71201 Sears Roebuck and Co Hoffman Estates IL 60179 U S A 1 5 AMP MANUAL BATTERY CHARGER CAUTION Read and Follow All Safety Rules and Operating Instructions Before Every Use of this...

Page 2: ...anual Battery Charger offers features to accommodate the needs for home use This manual will show you how to use your charger safely and effectively Please read and follow these instructions and preca...

Page 3: ...or snow Never charge a frozen battery If battery fluid electro lyte becomes frozen bring battery into a warm area to thaw before you begin charging Never allow battery acid to drip on charger when rea...

Page 4: ...look like Wiring diagram Replacement Parts List Sears 71201 Item 1 2 3 4 5 6 7 8 9 10 Description Case Top Case Bottom AC Linecord Output Cord Switch LED Asm Transformer Asm Owner s Manual Battery Cab...

Page 5: ...perconnectioncanresultinelectricalshock L WARNING Your charger should be grounded to reduce the risk of electrical shock Your charger is equipped with an electrical cord that has an equipment groundin...

Page 6: ...l caps no action is necessary Continue to the next step listed below Take time to read all battery manufacturer s specific precautions such as removing or not removing cell caps while charging and rec...

Page 7: ...ed metal part of the chassis or engine block Do not connect clamp to carburetor fuel lines or sheet metal parts IMPORTANT Wear safety glasses and face away from the battery when making connections 6 C...

Page 8: ...cable of at least 24 inches in length to the NEGATIVE battery post This cable will provide a safer connection because arcing and sparking will not occur directly over the battery The battery cable is...

Page 9: ...r battery you can calculate the approximate time needed to bring your battery to a full charge To convert Reserve Capacity to Amp Hours divide Reserve Capacity by 2 and add 16 Amp Hours Reserve Capaci...

Page 10: ...ave come in contact with the clamps to prevent corrosion 2 Coil the input and output cords neatly when storing the charger This will help prevent acci dental damage to the cords and charger 3 Occasion...

Page 11: ...connection at battery Shorted battery clamps Shorted battery Charger leads reversed on battery Check AC outlet Correct switch position and continue charging Unplug charger Reconnect clips then plug in...

Page 12: ...d Call 7 am 7 pm 7 days a week 1 800 366 PART 1 800 366 7278 For the location of a Sears Repair Service Center in your area Call 24 hours a day 7 days a week 1 800 488 1222 REPAIR SERVICES America s R...

Reviews: