Seametrics WMX SERIES Instructions Manual Download Page 5

SPECIFICATIONS

Page 3

FLOW RANGE (3” - 12”)

Meter 

Size

3”

4”

6”

8”

10”

12”

Gal/Min   Liter/Sec Gal/Min    Liter/Sec

Gal/Min     Liter/Sec Gal/Min       Liter/Sec Gal/Min      Liter/Sec Gal/Min   Liter/Sec

Minimum

7.5

.47

12

.75

32

2

60

3.8

95

6

130

8.2

Maximum

700

44.2

1,000

63

2,400

151.4

4,400

277.6

7,000

441.6

10,000

630.9

3”,4”, 6”, 8”, 10”, 12”

ANSI 150 lb. drilling

150 psi (10.3 bar) working pressure

 10˚ to 130˚ F (-12˚ to 54˚ C)
-40˚ to 158˚ F (-40˚ to 70˚ C)
+/- 1% of reading for flow between 10% to 100% of max flow

+/- 2% of reading for flow from cutoff to 10% of max flow
Ductile cast iron, powder coated

Welded steel, epoxy-coated

Noryl® 
Santoprene/Polypropylene
Diecast aluminum, powder-coated (non-IP68)   

Ductile Cast Iron (IP68)

316 stainless steel

EPDM

Rate Total

8

Gallon/Minute, Liter/Minute, Liter/Second, 

Gallon, Gallon x 1000, Liter, Liter x 1000, Mega Liter,

Cubic Feet/Minute, Cubic Meter/Hour, 

Cubic Meters, Cubic Meter x 1000, Cubic Feet,

Million Gallon/Day, Mega Liter/Day 

Cubic Feet x 1000 

WMX101:

 8-32 Vdc at 30 mA max, with auxiliary battery for continuous operation during power failures

NOTE:

 

Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation

WMX104:

 2 Lithium 3.6V “D” batteries, replaceable, 1 year life under continuous use.

             

WMX101:

 Current sinking pulse, opto-isolated, 30 Vdc at 10 mA max

WMX104:

 Pulse output available only with addition of post-factory output cable

High Frequency; 10 units/pulse; 100 units/pulse; 1000 units/pulse

 

3” 

4” 

6” 

8” 

      10”           12”

  25.228 

16.362 

6.307 

3.344      2.150        1.530

>20 microSiemens/cm
Hardware/software, conductivity-based
NEMA 4X Standard   (IP68 Option) 
NSF-61 (3” ONLY)

Pipe Sizes

Fittings

Pressure

Temperature Operating

 

Non-Operating

Accuracy

Materials 

Body (3” Only)

 

Body (4”-12”)

 

Liner (3” Only)

 

Liner (4”-12”)

 

Electronics Housing

 Electrodes

 

O-ring (3” Only)

Display  

 

Digits

 

Units

Power

Pulse Output   

Signal

 

 

Pulse Rates

 

 

High Frequency

 

 (pulse/gal)

Conductivity
Empty Pipe Detection

Environmental
Regulatory

SPECIFICATIONS*

*Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).

Summary of Contents for WMX SERIES

Page 1: ...WMX SERIES MUNICIPAL INDUSTRIAL MAGMETER INSTRUCTIONS WMX SERIES MUNICIPAL INDUSTRIAL MAGMETER INSTRUCTIONS 9 0 0 1 2 0 0 8 CERTIFIED COMPANY ISO WMX104 WMX101 168 WMX104 300...

Page 2: ...Recommendations Page 6 Full Pipe Recommendations Page 7 Inputs Outputs and Operation Power Pulse Output High Frequency K Factor Display Reading Page 8 Connections Diagrams AO55 WMX101 FT420 WMX101 DL7...

Page 3: ...far enough upstream for complete mixing to occur before the fluid reaches the meter The submersible units 168 option are rated IP68 NEMA 6P for applications where the meter may be under water up to a...

Page 4: ...nt security seal cross drilled screws 2 for tamper evidence Flanges ANSI 150 lb drilling Equalization lug Rate and total indicator Internal Data Logger Optional WMX104 300 IP68 housing standard for 3...

Page 5: ...Day Cubic Feet x 1000 WMX101 8 32 Vdc at 30 mA max with auxiliary battery for continuous operation during power failures NOTE Using an unregulated power supply 18 Vdc may damage the meter due to AC l...

Page 6: ...not require any form of field calibration Caution These flow sensors are not recommended where installation fault may expose the flow sensor to boiler pressure and temperature Maximum recommended temp...

Page 7: ...nd the flange plate For the best electrical bonding remove rust and paint to expose clean bare metal where the equalization flange plate lock washer contacts the pipe flange Connection must be inspect...

Page 8: ...PIPE RECOMMENDATIONS 1X 2X 2X 2X 1X 5X 5X 5X Reduced Pipe Two Elbows In Plane Two Elbows Out Of Plane Expanded Pipe Swirling Flow Propeller Meter Partially Open Butterfly Valve 1X 1X 1X 1X Swirling F...

Page 9: ...racy Intermittent air bubbles pass over electrode Possible sediment build up WMX WMX WMX WMX Recommended Allows air to bleed off Recommended Keep pipe full at meter for accuracy Recommended Keeps pipe...

Page 10: ...pproximately ten years Pulse Output WMX101 The WMX101 cable also provides pulse output that can be used for remote reading 4 20 mA signal conversion datalogging and telemetry applications See page 7 f...

Page 11: ...elded Direct Burial Cable 22 AWG Stranded White Green Drain Wire Do Not Use External Power Input Required 12 32 Vdc DL75 or DL76 WMX101 CONNECTIONS DIAGRAMS WMX101 The WMX101 requires a power source o...

Page 12: ...r or far enough upstream to allow complete mixing of fluids before meter Add pull up resistor For details refer to Connecting to PLCs Technical Bulletin at www seametrics com Change output connections...