Seametrics PT35 Instructions Download Page 3

3 of 4

Operation

Test for Timer Output. To test the timer (either timer in
the case of the PT35) press the "TEST 1" or "TEST 2"
button. The red output indicator should light, and re-
main on for the previously-set number of seconds.

Standard Operation. After setting (when the unit has
returned to normal operation, indicated by no blinking
indicators) any display can be selected at any time by
turning the knob. For the PT35, turning the knob clock-
wise causes clockwise rotation among the indicator
lights. Stop turning the knob after arriving at the de-
sired display. This is the display that will remain until
another display is selected.

PT34 CONNECTIONS DIAGRAM

PT35 CONNECTIONS DIAGRAM

GND

SIGNAL

EXTERNALLY-PACED
METERING PUMP

DRY CONTACT
TYPE METER (MR,WPR)

GND

GND

SIGNAL

SIGNAL

+12 VDC

+12 VDC

PUMP+

SOLID STATE TYPE
METER (ME,IP,WT)

SOLID STATE TYPE
METER (ME,IP,WT)

INPUT CONNECTIONS

NO  NC  N  G

Ground
Neutral
Hot Normally Closed
Hot Normally Open

H   V   G

P

G

S

V

OUTPUT 

Ground

Neutral

Hot

3AG-5A-SB Fuse

POWER

Ground

Neutral

Hot

NO  NC  N  G

NO  NC  N  G

Hot Normally Open

Hot Normally Closed

Neutral

Ground

Ground
Neutral
Hot Normally Closed
Hot Normally Open

H   V   G

P

G

S

V

OUTPUT 1 

OUTPUT 2 

3AG-10A-SB Fuse

POWER

AR

CH

IVE

D