Seametrics PE202 Instructions Manual Download Page 3

PE202 INSTRUCTIONS

Seametrics • 253.872.0284 

Page 3 

seametrics.com

The 

PE202

  magmeter  is  designed  for  low-flow  chemical 

injection  or  difficult-to-meter  applications  with  pulsating 

metering pumps in 3/4” to 1/4” pipe/tube. The housing is 

made of sturdy splashproof HDPE plastic.

With  no  moving  parts,  the  PE202  can  handle  fluids 

containing particulate matter without clogging or jamming, 

keeping maintenance at a minimum. With no metallic parts 

(100% PVDF body and PVDF carbon fiber-filled electrodes), 

the meter is corrosion-resistant and compatible with a 

wide range of chemicals (consult factory for chemicals and 

concentrations).  Accuracy  is  maintained  with  conductive 

fluids  (>20  microSiemens)  of  varying  viscosities  and 

densities.

FEATURES

GENERAL INFORMATION

The PE meter is compact enough to fit most pump/injection 

systems.  With zero straight pipe required after an elbow, 

it can be easily mounted in tight spaces.  The mounting 

bracket adds stability.  

The PE meter has an optoisolated current sinking pulse 

output that can be connected to the Seametrics FT430/440 

rate/total display or FT520 batch processor, as well as an 

optoisolated 4-20 mA current loop for analog devices. 

Outputs and power are provided through a cable with 

8-pin female circular connector. 

Mounting bracket

Sturdy HDPE housing

8-pin circular bulkhead connector, 20 foot (6 meter) cable provided

½” male NPT

fittings standard

Internals made of chemical and corrosion-resistant PVDF

Threaded male or female NPT adapters

can be purchased separately

(available in PVDF and PP)

(Female NPT available in 1/2” only)

Summary of Contents for PE202

Page 1: ...PROUDLY MADE IN THE USA C e rtified Compa n y ISO 9001 2008 PE202 Low Flow Magmeter Instructions ...

Page 2: ...ge 5 Installation Positioning Page 6 Mounting Page 6 Piping Page 6 Power Supply Page 6 Grounding Page 6 Connections General Connection Information Page 7 Pulse Output Only with FT520 Page 7 4 20 mA Device and FT430 440 with Single Power Supply Page 7 Dual Power Supply with Loop Isolation Page 7 Operation General Operation Information Back Troubleshooting Problem Back Probably Causes Back Things to...

Page 3: ...mens of varying viscosities and densities FEATURES GENERAL INFORMATION The PE meter is compact enough to fit most pump injection systems With zero straight pipe required after an elbow it can be easily mounted in tight spaces The mounting bracket adds stability The PE meter has an optoisolated current sinking pulse output that can be connected to the Seametrics FT430 440 rate total display or FT52...

Page 4: ... mA max Optoisolated 4 20 mA current loop 7 Vdc plus load voltage drop min 50 Vdc max 075 500 pulses liter 1892 pulses gallon 038 1000 pulses liter 3785 pulses gallon Power 10 15 Vdc 150 mA linear power supply recommended Conductivity 20 microSiemens Empty Pipe Detection Hardware software conductivity based Environmental NEMA 4X standard IP66 splashproof standard Specifications subject to change P...

Page 5: ...K SHARP EDGES DRAWN MECH ENG ELEC ENG MFG ENG Q A DATE NAME TITLE SIZE B DWG NO REV SHEET 1 OF 1 CP PE202 038 DO NOT SCALE DRAWING A COMMON PARTS PE202 038 Mounting Bracket 7 2 18 3 cm with adapters as shown 4 2 10 7 cm meter without adapters 3 5 8 9 cm 2 0 5 0 cm 4 2 10 7 cm 2 1 5 3 cm Meter ID 038 0 19 075 0 50 4 2 METER WITHOUT ADAPTERS 7 2 WITH ADAPTERS AS SHOWN 3 5 2 0 4 2 2 1 A B C D 2 3 4 5...

Page 6: ...ic tubing can be used with the meter The standard NPT fittings can be used with or without NPT adapters on 3 4 or 3 8 pipe If used apply Teflon tape onto the NPT fittings NPT adapters should be hand tightened onto the fittings Thoroughly clean the pipe threads and nose and apply Teflon tape to adapter threads Hold adapters with a wrench while tightening the pipe to prevent damage to the meter Powe...

Page 7: ...h FT520 _ SEN 1 SEN 2 _ 12 G 12 Vdc power Green Brown White Red Pin 8 Pin 2 Pin 3 Pin 1 PE202 FT520 4 20 mA Device and FT430 440 with Single Power Supply Important 4 20mA device input resistance must not exceed 250 Ω Dual Power Supply with Loop Isolation _ S _ _ _ 4 20 mA loop 12 15 Vdc 4 20 mA device PE202 Sensor Input FT430 440 Power 4 8 3 1 2 7 Yellow Red Green White Blue Brown May be external ...

Page 8: ...and register zero flow OPERATION The 4 20 mA signal outputs 4 mA at zero flow and 20 mA at 20 gallons minute flow or 3 gallons per minute depending on model The pulse signal is a 50 duty cycle pulse set at PE202 075 500 pulses liter 1892 pulses gallon PE202 038 1 000 pulses liter 3785 pulses gallon Problem Probable Causes Things to try No output Reversed flow direction Reverse flow connections Emp...