background image

 

 

Pump has double stages and the sound of each stage is different. 2nd stage will produce noisy sound since 
the dual cylinders pumping. 

 

When operate the 80DB model by its extension power cord, please Take Off the power cord from the pump 
power terminal when finished. Keep it connected may cause serious Electrical Short Circuit Fire. 

 

Before connecting the pump of the battery, please make sure the battery voltage is 12V, and the max 
loading of power source can support 40A current.  

 

Please return the unit to the manufacturer or the place of purchase for service or replacement. Repairs may 
only be performed by an authorized service technician. 

 

Please SAVE this instruction manual. The manufacturer is not responsible for damage caused as a result of 
improper use or failure to observe these instructions. 

 

Don't let the pump overheat:  

 

 

You can use your original valve adaptor other than the coming valve adaptors if it is better.  

 

Test Run is necessary before your first time using. Don't leave the pump running unattended even 
considering its auto stop feature! You can stop the pump at any time by using the power button. 

 

Do not use it for more than 30 minutes continuously. And the 2

nd

 (cylinder) stage continued working time 

is limited to 5 minutes. Long periods of use can cause overheating and damage the inflator.   

 

Smaller valve fittings can limit the airflow speed, the pump could be easier to get overheat, your attention 
is very important and the pump continued working time must be reduced.  

 

Low quality power source will slow down a lot pump running at high pressure 2nd stage; it can cause the 
pump over heat quickly and give the damage. We do not suggest using a non certified battery to operate. 

 

If the air hose (pump side) temperature is over 60ºC (92ºF), please stop using the pump to let it cool down.  

 

IF the environment temperature is high, the max pump continued working time may be reduced. 

 

This pump is built in the air filter, Please first check the Air Filter if the air flow is unusual.  

 

Compatible List 

Air Valves:  

 

 

This pump is suitable for the products that are using the HR (Halkey-Roberts), Bravo

 

or similar type air 

valve. This kind of air valve has a turning pin at the middle to control the valve’s Open & Closed position. 
There are universal valve adaptors supplied with the pump to fit it. 

 

Bravo type air valves have a pin in the middle for pushing instead of turning to control its Open & Closed 
position. Our universal valve adaptors will fit Bravo air valves. 

 

Please keep the air valve it the Closed Position when inflating the chamber. 

 

HR Air Valve                                     Bravo Air Valve 

Summary of Contents for 80DB

Page 1: ... when using near the water or metal Don t use the pump close to your Fuel Tank or An Open Flame Pump s Max Pressure can reach 11 6 PSI Please make sure the pump with correct pressure setting for your chamber before pumping at every time This Pump can hold the last pressure setting after disconnect the power Factory default setting is 25Kpa 3 6 PSI when the pump is new Keep the pump away from Child...

Page 2: ...linder stage continued working time is limited to 5 minutes Long periods of use can cause overheating and damage the inflator Smaller valve fittings can limit the airflow speed the pump could be easier to get overheat your attention is very important and the pump continued working time must be reduced Low quality power source will slow down a lot pump running at high pressure 2nd stage it can caus...

Page 3: ...ave a built in diaphragm to stop air from escaping when inflating The Boston type Leafield C7 air valve use a built in rubber diaphragm or diaphragm spring they will cause excessive back pressure When inflating chambers with this style of valve you must monitor the pump closely This style of valve causes the pump to overheat prematurely because of the back pressure caused by the valve diaphragm Th...

Page 4: ...es Mode KPa as its pressure display 10KPa 100mbr 1 45 PSI Factory default working pressure is set as 25KPa 3 6 PSI This pressure is suitable for most inflatable boats Min set pressure is 1 PSI 8Kpa if you only need lower pressure than 1 PSI you can keep monitoring the screen pressure reading and stop the pump manually Press the POWER button to start During inflation the left hand side of LCD scree...

Page 5: ... charger 80DB model has a built in battery travel charger The type of this battery is 12V gel battery lead acid type battery capacity 7AH The battery will have 500 Cycles over 8 years life time if you can follow this maintenance manual The charger is 110 240V travel type with double charging procedures When you plug in the charge and connect with the pump a red light showing on the charger can ind...

Page 6: ...r plate off Take out the air filter and clean it Replacement Parts List Please contact seller if you need parts for replacement 1 Air hose 2 Air valve adaptors 3 Lead Acid battery or Lithium ion battery 4 AC Charger 13 8V or 12V 5 Power cord or Extension power cord 4 Carrying bag 80D or 80DB 5 Turbine fan motor unit 6 Cylinder unit for 2nd stage 7 motor for cylinder 8 Electric sensor for air press...

Page 7: ...Built in 7AH Lead Acid Gel Battery 110 240V Travel Charger Extension power cord 9ft long for pump emergency use or battery charging Extension Pump Power terminal Output for other device 12V 10A 120W Max Charger Current DC 14V 1 A Max charging time 72 Hours including Battery Recovery Step Shipping weight 6 2KG 13 6Lbs Packing 43x45x37cm 8x8x14 inches Kite Version Additional 4 valve adaptors for Inf...

Page 8: ... dernier réglage de pression après couper l alimentation Réglage par défaut d usine est 25 kPa 3 6 PSI lorsque la pompe est nouveau Gardez la pompe à partir des enfants Rangez la pompe dans un endroit sec et frais loin de l eau le soleil et la chaleur Vous pouvez avoir besoin de savoir Examiner soigneusement la pompe à air et votre produit gonflable avant de commencer Se il vous plaît font que vot...

Page 9: ...coup courir à haute pression 2ème étape il peut causer la pompe à feu rapidement et donner les dégâts Nous ne suggérons pas d utiliser une batterie non certifié pour fonctionner Si la température tuyau d air côté pompe est plus de 60ºC 92ºF se il vous plaît arrêter d utiliser la pompe pour le laisser refroidir Si la température de l environnement est élevée la pompe max continué temps de travail p...

Page 10: ...membrane en caoutchouc et ressort intégré ils vont provoquer pression excessive Lors du gonflage chambres avec ce style de vanne il faut suivre de près la pompe Ce type de vanne provoque une surchauffe de la pompe prématurément en raison de la contre pression causée par la membrane de soupape Cette pression arrière donnera le capteur de la pompe une fausse lecture et provoquer la 2ème étape de com...

Page 11: ...n affichage de la pression 10 kPa 100mbr 1 45 PSI La pression de travail par défaut d usine est défini comme 25 kPa 3 6 PSI Cet pression est approprié pour la plupart des bateaux gonflables Min réglée pression est de 1 PSI 8 kPa si vous ne devez pression inférieure à 1 PSI vous pouvez continuer à surveiller la lecture de pression de l écran et arrêter la pompe manuellement Appuyez sur le bouton d ...

Page 12: ...Z ENDOMMAGER EXTREME DE VOTRE gonflable et à la pompe Batterie Maintenance 80dB À propos de la batterie et le chargeur modèle de 80dB est équipé d un chargeur de batterie et Voyage Le type de cette batterie est batterie gel 12V type plomb acide capacité de la batterie 7AH La batterie aura 500 Cycles plus de 8 ans temps de vie si vous pouvez suivre ce manuel d entretien Le chargeur est de 110 240V ...

Page 13: ...is ou plus va endommager la batterie Si vous avez facturé entièrement la pompe juste avant le stocker il ne devrait pas être nécessaire de le recharger pendant des mois Si vous voyez une icône de batterie faible sur l écran LCD se il vous plaît recharger la batterie dans les 24 heures Si la batterie ne tiendra pas une charge plus la batterie peut avoir besoin d être remplacé dans la plupart des ca...

Page 14: ...d achat et dans les 6 mois Le client doit payer pour les deux façons frais de transport si la réclamation de garantie est de plus de 180 jours à compter de la date d achat Seulement Seamax donnera 2 ans de garantie pour les pompes nous avons vendus Seamax desservira toutes les pompes au Canada Adresse 120 11791 Machrina Way Richmond BC Canada Tel 604 277 7766 Se il vous plaît garder votre reçu et ...

Page 15: ...15 Seamax Marine and Outdoor 120 11791 Machrina Way Richmond BC Canada V7A 4V3 Toll free 1 877 907 7766 Tel 604 277 7766 www seamaxboat com sales seamaxboat com ...